Authorized Panduit Distributor
Panduit CJSQ688TGBL - The Mini-Com Cat 6 Shielded RJ45 TG Keyed PanView iQ(tm) Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable and function with Panduit's PViQ(tm) system. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates.
Panduit

CJSQ688TGBL

UPC: 074983296248


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Minimum Qty: 10

Multiplier: 1

*Contact for lower quantities*

Overview

The Panduit Mini-Com Cat 6 Shielded RJ45 TG Keyed PanView iQ(tm) Jack Module (SKU: CJSQ688TGBL) is engineered for high-speed data transmission and robust network infrastructure. This module is designed to terminate 4-pair, 22-26 AWG twisted pair cable and integrates seamlessly with Panduit's PViQ(tm) system. Each jack module undergoes 100% factory testing to ensure it exceeds industry standard performance requirements for Category 6. The innovative TG style termination eliminates the need for specialized termination tools, simplifying installation and reducing labor costs. Each jack is individually serialized, providing critical traceability for network management and compliance. This shielded RJ45 jack is fully compatible with the Panduit Mini-Com Modular Patch Panels and Faceplates, allowing for a cohesive and high-performance network build-out. The shielded design offers enhanced electromagnetic interference (EMI) protection, crucial for maintaining signal integrity in electrically noisy environments. It supports high-speed data transmission, making it suitable for demanding applications where reliable performance is paramount. The TG termination method ensures a secure and consistent connection without the risk of tool-induced damage. Leverage the PViQ(tm) system for intelligent network monitoring and management capabilities. Panduit's commitment to quality is evident in the rigorous testing and serialization of each module, ensuring reliability and accountability within your network infrastructure. This jack module is manufactured in the US, adhering to high production standards.
  • Cat 6 Shielded RJ45 TG Keyed Jack Module for 4-pair, 22-26 AWG cable
  • TG style termination eliminates the need for a termination tool
  • 100% factory tested to exceed industry standard performance requirements
  • Individually serialized for traceability
  • Compatible with Panduit Mini-Com Modular Patch Panels and Faceplates

Specifications

Application
Shielded
Cable Entry
T568A/T568B
Color
Blue
Color
Black
Connection Type
RJ45
Depth
1.51 In.
Height
0.73 IN
Material
Plastic
Material
ABS/Tin Plated Over Phosphorous Bronze/Zinc/Plastic
Model
Mini-Com
Mounting Type
Modular Patch Panel/Faceplate
Series
Mini-Com PanView iQ
Slot Capacity
1
Standard
Exceeds Channel and Component Requirements of ANSI/TIA-568.2-D and ISO 11801 Standards for the Respective Category, Meets IEC 60603-7, Supports 2500 Connection Cycles with IEEE 802.3af / 802.3at and 802.3bt Type 3 and Type 4, UL 1863 and UL 2043 and RoHS
Type
Jack Module
Width
0.62 In.
Package Dimensions (L x W x H)
3.5 IN x 3 IN x 0.5 IN
Package Weight (Imperial)
0.042 lbs
The Mini-Com Cat 5e UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is black.

CJ5E88TGBL

The Mini-Com Cat 5e UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is black.
The NetKey Fiber Drawer comes preloaded with 24 LC Duplex adapters for OS1/OS2 singlemode fiber for fast and easy cabling and installation.

NKFD1W24BUDLCZ

The NetKey Fiber Drawer comes preloaded with 24 LC Duplex adapters for OS1/OS2 singlemode fiber for fast and easy cabling and installation.
The 2-Post rack provides a reliable foundation for mounting telecommunications and data center equipment. The 84 inch tall rack accepts 19-inch wide equipment with mounting rails that have #12-24 EIA universal mounting hole spacing, and printed numbering from the bottom up. A range of cable managers and accessories work with the rack. The 3-inch deep channel rack is UL listed for 1,000 pounds and is made of extruded aluminum. The rack is 45 RU and black.

R2P

The 2-Post rack provides a reliable foundation for mounting telecommunications and data center equipment. The 84 inch tall rack accepts 19-inch wide equipment with mounting rails that have #12-24 EIA universal mounting hole spacing, and printed numbering from the bottom up. A range of cable managers and accessories work with the rack. The 3-inch deep channel rack is UL listed for 1,000 pounds and is made of extruded aluminum. The rack is 45 RU and black.
The NetKey Fiber Drawer comes preloaded with 12 SC Duplex adapters for OS1/OS2 singlemode fiber. It features zirconia split sleeves.

NKFD1W12BUDSCZ

The NetKey Fiber Drawer comes preloaded with 12 SC Duplex adapters for OS1/OS2 singlemode fiber. It features zirconia split sleeves.
The NetKey Fiber Drawer comes preloaded with 24 LC Duplex adapters for OM3/OM4 multimode fiber for fast and easy cabling and installation.

NKFD1W24AQDLC

The NetKey Fiber Drawer comes preloaded with 24 LC Duplex adapters for OM3/OM4 multimode fiber for fast and easy cabling and installation.
The NetKey Fiber Drawer comes preloaded with 12 SC Duplex adapters for 50 m (OM3/OM4) multimode fiber. It features zirconia split sleeves.

NKFD1W12AQDSC

The NetKey Fiber Drawer comes preloaded with 12 SC Duplex adapters for 50 m (OM3/OM4) multimode fiber. It features zirconia split sleeves.
The NetKey Fiber Drawer comes preloaded with 12 LC Duplex adapters for OS1/OS2 singlemode fiber. It features zirconia split sleeves.

NKFD1W12BUDLCZ

The NetKey Fiber Drawer comes preloaded with 12 LC Duplex adapters for OS1/OS2 singlemode fiber. It features zirconia split sleeves.
The air inlet duct fits in a 2 RU footprint, resides in-line and below switch and provides cold aisle airflow to Cisco Nexus N2K and Catalyst 9448E switches. It optimizes the thermal efficiency of the switch in cabinet applications.

CDE2

The air inlet duct fits in a 2 RU footprint, resides in-line and below switch and provides cold aisle airflow to Cisco Nexus N2K and Catalyst 9448E switches. It optimizes the thermal efficiency of the switch in cabinet applications.

Frequently Asked Questions

What wire gauge is compatible with this module?

The module is compatible with 22 – 26 AWG solid or stranded cable.

What standards does this module comply with?

It complies with ANSI/TIA-568-C.2, ISO 11801 Class EA, and FCC standards.

What type of cable does this module support?

It supports shielded twisted 4-pair, 100 ohm cable.

Does this module support Power over Ethernet?

Yes, it meets IEEE 802.3af and IEEE 802.3at standards for PoE applications.

What is the maximum cable diameter for termination?

The maximum overall cable O.D. for termination is 0.330 in.

Is this module compatible with non-PViQ patch cords?

No, the module has positive keying features to prevent connections with non-PViQ patch cords.

How is the module terminated?

The module uses a forward motion termination method that does not require a punchdown tool.

What tools are recommended for termination?

The recommended termination tools are the TGJT or EGJT for optimal performance.

What is the UL rating for this module?

The module is UL 1863 approved.

What is the operating voltage for this product?

The product operates at 24V DC, with a range of 20-28V DC.

How to Install the CJS688TGBUY Controller

This guide provides step-by-step instructions for installing and configuring the CJS688TGBUY Controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Prepare the installation site

    Select a suitable location for the controller installation, ensuring it is dry and away from any potential lightning hazards.

  2. Mount the controller

    Secure the controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  3. Connect the wiring

    Strip the ends of the data cables and connect them to the appropriate terminals on the controller, following T568A or T568B wiring standards.

  4. Trim conductors

    Trim the conductors flush and ensure that any drain wire is also trimmed if present, to avoid interference.

  5. Verify connections

    Use a multimeter to check the continuity of the connections and ensure there are no shorts.

  6. Configure the controller

    Follow the manufacturer's instructions to program the controller settings as required for your specific application.

  7. Calibrate the system

    Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.