Panduit CJ588ORY - The Mini-Com Cat 5e UTP RJ45 Leadframe Jack Module is designed to terminate 4-pair, 22-24 AWG twisted pair cable. Each module is 100% factory tested for continuity. Contacts are plated with 50 microinches of gold for superior performance. Jack modules are compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is Orange.
Panduit

CJ588ORY

UPC: 074983035038


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Minimum Qty: 10

Multiplier: 1

*Contact for lower quantities*

Overview

The Panduit CJ588ORY Mini-Com Cat 5e UTP RJ45 Leadframe Jack Module is a factory-tested, high-reliability connectivity solution for structured cabling systems. Designed to terminate 4-pair, 22-24 AWG twisted pair cables, this jack module ensures consistent signal integrity with 50 microinches of gold-plated contacts, reducing insertion loss and maintaining performance over extended use. Each module undergoes 100% factory testing for continuity, guaranteeing error-free connections in critical network environments. Engineered for compatibility with Panduit’s Mini-Com Modular Patch Panels and Faceplates, the CJ588ORY integrates seamlessly into existing infrastructure, supporting standard RJ45 connections. The orange jack module is constructed from durable polycarbonate (PC) and operates at a frequency of 100 MHz, making it ideal for data centers, enterprise networks, and industrial applications requiring Cat 5e performance. With 8 poles and a panel-mount design, this module is manufactured in the US to meet stringent quality standards for long-term reliability. The CJ588ORY is a cost-effective, high-performance choice for terminating Cat 5e cables in structured cabling deployments. This jack module is designed to terminate 4-pair, 22-24 AWG twisted pair cable. Each module is 100% factory tested for continuity. Contacts are plated with 50 microinches of gold for superior performance. Jack modules are compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is Orange.
  • Terminates 4-pair, 22-24 AWG twisted pair cable
  • 50 microinches gold-plated contacts for signal integrity
  • 100% factory-tested for continuity
  • 100 MHz frequency rating for Cat 5e performance
  • Compatible with Mini-Com Modular Patch Panels and Faceplates

Specifications

Application
Unshielded
Cable Entry
T568A/T568B
Color
Orange
Connection Type
RJ45
Depth
1.37 In.
Frequency
100 MHz
Material
ABS
Material
Gold-plated contacts
Material
Plastic
Material
N/A
Model
Mini-Com
Model
Mini-Com®
Mounting Type
Panel-Mount
Mounting Type
Modular Patch Panel/Faceplate
Mounting Type
Panel/faceplate
Poles
8
Poles
8P8C
Poles
8P8C (RJ45)
Poles
4P
Series
Mini-Com
Series
Mini-Com Cat 5e UTP
Size
Cat 5e UTP RJ45
Slot Capacity
1
Standard
Exceeds Channel and Component Requirements of ANSI/TIA-568.2-D and ISO 11801 Standards for the Respective Category, Meets IEC 60603-7, Supports 2500 Connection Cycles with IEEE 802.3af / 802.3at and 802.3bt Type 3 and Type 4, UL 1863 and UL 2043 and RoHS C
Type
Jack Module
Width
0.62 In.
Package Dimensions (L x W x H)
3.65 IN x 3.25 IN x 0.9 IN
Package Weight (Imperial)
0.026 lbs
Keyed, Category 5e, RJ45, 8-position, 8-wire universal shielded black module with integrated shield. Orange.

CJSK5E88TGOR

Keyed, Category 5e, RJ45, 8-position, 8-wire universal shielded black module with integrated shield. Orange.

Frequently Asked Questions

What is the operating temperature range?

The operating temperature range is 14°F to 140°F (-10°C to 60°C).

What type of cable does the module support?

The module supports solid, 4-pair, 24 – 22 AWG, 100 ohm unshielded twisted pair cable.

Does it require a punchdown tool for installation?

No, the module does not require a punchdown tool for installation.

What compliance standards does the module meet?

The module meets ANSI/TIA-568.2-D Category 5e and ISO 11801 Class D standards.

Is the product RoHS compliant?

Yes, the product is RoHS compliant.

What is the conductor termination range?

The conductor termination range is 24 – 22 AWG with insulation diameters of 0.035 in. to 0.048 in.

What is the maximum power over Ethernet supported?

The module supports Power over HDBaseT up to 100 watts.

What are the dimensions of the module?

The module dimensions are 0.62 in x 1.37 in x 0.72 in.

What types of applications is this module suitable for?

It is suitable for Ethernet, voice/data systems, and VoIP applications.

What tools are recommended for installation?

Recommended tools include the CJT-X termination tool and jacket stripping tool CJAST.

How to Install the Mini-Com Mini-Jack Modules

This guide provides step-by-step instructions for installing and wiring the Mini-Com Mini-Jack Modules (CJ588) according to TIA/EIA standards.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Snipping tool, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, PVC or Plenum rated 22-24 AWG cable

  1. Prepare the cable

    Remove all but one twist per pair of the cable conductors, smooth the conductors, and arrange them in the proper color sequence according to T568A or T568B standards.

  2. Terminate the conductors

    Insert the prepared conductors into the Mini-Jack Module according to the color-coded wiring diagram. Ensure that each conductor is fully seated in the insulation displacement contacts.

  3. Secure the module

    Mount the Mini-Com Mini-Jack Module securely using the provided mounting screws. Verify that it is firmly attached and level.

  4. Test the installation

    Use a multimeter to verify the continuity and proper termination of each connection. Ensure that the installation meets TIA/EIA 568-B performance guidelines.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.