Contact for Pricing
Overview
- Designed for 4-foot (1200mm) aisles
- Compatible with 42 or 45 RU tall cabinets
- Integrates with cabinet-supported cold/hot aisle containment
- Manages data center temperatures effectively
- White finish for a clean aesthetic
Specifications
Color | White |
Depth | 3.44 In. |
Material | Steel |
Size | 4-foot (1200mm) aisle, works with cabinets that are 42 or 45 RU tall |
Standard | RoHS Compliant |
Type | Cabinet Door Frame Adapter |
Width | 78.3 in |
Width | 1988.82 mm |
Package Dimensions (L x W x H) | 102 IN x 30 IN x 6 IN |
Package Weight (Imperial) | 49.4 lbs |

ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
STP6X12MIG
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What are the height options for EOR vertical wall panels?
Adjustable EOR vertical wall panels are available in 16 in – 26 in, 26 in – 38 in, and 38 in – 66 in heights for various aisle widths.
What is required to install the sliding door adapter kit?
Drilling into the floor is required to install the sliding door adapter kit.
What aisle widths do the sliding doors support?
The sliding doors can be installed in 3 ft and 4 ft aisles and mount to 600mm, 700mm, and 800mm Net-Access™ N-Type and S-Type Cabinets.
What are the height options for vertical wall panels?
Adjustable vertical wall panels are available in 16 in – 26 in, 26 in – 38 in, and 38 in – 66 in heights for various cabinet widths.
What cabinets are compatible with this containment system?
The system is compatible with Panduit Net-Access™ N-Type and S-Type Cabinets. It also integrates with FiberRunner® and Wyr-Grid® Overhead Cable Routing Systems.
Is the Net-Contain system energy efficient?
Yes, it is a passive system with no moving parts, making it more energy efficient than forced-air options. It can reduce cooling energy costs by 25-30%.
What heat loads can the Net-Contain system manage?
The system can address heat loads up to 20kW per cabinet, enabling dense server applications and eliminating data center hot spots.
What is the primary function of the Net-Contain system?
The Net-Contain™ Passive Hot Aisle Containment System segregates cold and hot air streams by enclosing the hot aisle, capturing exhaust air for cooling units.
What heat loads can the Net-Contain system manage?
The system can address heat loads up to 20kW per cabinet, enabling dense server applications and eliminating data center hot spots.
What are the height options for EOR vertical wall panels?
Adjustable EOR vertical wall panels are available in 16 in – 26 in, 26 in – 38 in, and 38 in – 66 in heights for various aisle widths.
How to Install the C2CAC08F04IRB1 Ceiling Structure
This guide provides step-by-step instructions for installing the C2CAC08F04IRB1 ceiling structure, including mounting, wiring, and initial configuration.
Estimated time: 1h
Tools needed:
Screwdriver, Level, Wire strippers
Supplies needed:
M5 screws, Foam seal, Ceiling panels, Aisle beam, Ceiling panel stops
- Install the Aisle Beam
Secure the aisle beam to the designated mounting points using M5 screws. Ensure the beam is level before tightening.
- Attach Ceiling Panel Stops
Install the ceiling panel stops at the ends of the aisle beam using M5 screws. Ensure they are securely fastened to prevent panel movement.
- Mount Ceiling Panels
Align the ceiling panels with the aisle beam and panel stops. Secure each panel in place using the provided hardware, ensuring a tight fit.
- Apply Foam Seal
Cut the foam seal to the appropriate length and apply it along the edges of the ceiling panels to ensure a tight seal against air leakage.
- Verify Installation
Check all connections and ensure that the ceiling structure is stable and secure. Use a level to confirm that the panels are properly aligned.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.