Panduit C2CAC04ABWPAB1 - The Net-Contain Blanking Panel blocks open spaces, for use with cabinet supported cold aisle containment systems using row base cooling equipment to manage temperatures in the data center. The panel is 1950mm high by 400mm wide and is black.
Panduit

C2CAC04ABWPAB1

UPC: 074983921836


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Panduit Net-Contain Blanking Panel (SKU: C2CAC04ABWPAB1) is engineered to optimize thermal management within data centers by effectively blocking open spaces in cabinet-supported cold aisle containment systems. This panel is specifically designed for integration with row-based cooling equipment, ensuring that cold air is directed precisely where it's needed. By preventing the recirculation of hot air back into the cold aisle, the Net-Contain Blanking Panel significantly enhances cooling efficiency. This leads to more stable and consistent temperature control, which is crucial for high-density server environments. The panel measures 1950mm in height and 400mm in width, providing comprehensive coverage for open rack sections. Its black finish offers a clean aesthetic that complements most data center designs. Manufactured in the US, this durable panel is a key component for maintaining optimal operating conditions, reducing energy consumption by minimizing wasted cooling capacity, and supporting the reliability of critical IT infrastructure. It is an essential accessory for any facility implementing effective airflow management strategies.
  • Blocks open spaces in cabinet-supported cold aisle containment systems.
  • Optimizes thermal management with row-based cooling equipment.
  • Prevents air recirculation, improving cooling efficiency.
  • Dimensions: 1950mm high x 400mm wide.
  • Durable black finish for professional data center aesthetics.

Specifications

Color
Black
Material
Steel
Standard
RoHS Compliant
Type
Blanking Panel
Width
15.74 in
Width
399.796 mm
Package Dimensions (L x W x H)
22.5 IN x 10.5 IN x 7 IN
Package Weight (Imperial)
10.55 lbs
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
DIN Rail ? DIN 35

ARH 1656

DIN Rail ? DIN 35
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray

PDCP2078

DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

STP6X12MIG

This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the static load rating of the cabinet?

The static load rating is 3000 lbs. for the cabinet.

What is the rolling load rating of the cabinet?

The rolling load rating is 2500 lbs. for the cabinet.

What is the installation time reduction with the leveling feet?

The innovative leveling feet design reduces installation time by up to 80%.

What safety features are included in the cabinet?

The entire cabinet is fully electrically bonded, requiring no grounding whips for safety.

What are the cabinet width options available?

Cabinet widths available are 600mm, 700mm, and 800mm.

What heights are available for the cabinets?

Cabinet heights available are 42RU, 45RU, and 48RU.

Are the cabinets compatible with other Panduit products?

Yes, the cabinets are compatible with various Panduit product lines including FiberRunner®.

What are the color options for the cabinets?

The cabinets are available in black and white color options.

What is the benefit of the integral cabinet air seal?

The integral cabinet air seal improves thermal management and reduces cooling energy consumption.

How can I improve cable management in the cabinet?

Use modular snap-in fingers that align with rack spaces for cable management.

How to Install the C2CAC04ABWPAB1 Row Base Cooler

This guide provides step-by-step instructions for installing the C2CAC04ABWPAB1 Row Base Cooler, including wall panel installation, bracket attachment, and sealing procedures.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Foam seals, Blanking panels, Top brackets

  1. Install the Wall Panel

    Refer to CM596 for the initial installation of the wall panel. Ensure it is securely mounted and aligned.

  2. Attach Foam Seal to Wall Panel

    Trim the foam seal to the required lengths and attach it to one side of the wall panel, avoiding the side that will face the cold aisle.

  3. Install the Top Brackets

    Insert the first top bracket into the wall panel adjacent to the row base cooler unit. Align the holes and secure it with two M5 x 12mm button head screws, leaving them loose.

  4. Slide Wall Panel into Place

    Slide the wall panel onto the top bracket, ensuring the front is aligned with adjacent wall panels.

  5. Secure the Wall Panel

    Secure the wall panel to the top brackets using four M5 x 12mm button head screws and tighten all previously loose screws.

  6. Check Distance to Row Base Cooler

    Measure the distance from the bottom of the wall panel to the top of the row base cooler unit. If less than 89mm (3.5 inches), proceed with the blanking panel; if more, use the blanking panel extension.

  7. Attach Blanking Panel

    If the blanking panel extension is not needed, slide the blanking panel into place behind the wall panel and secure it with two M5 x 12mm button head screws.

  8. Adjust Height of Blanking Panels

    Loosely adjust the height of the blanking panels to ensure a tight seal with the row base cooler unit, then tighten the screws.

  9. Install Floor Seal

    Measure the distance from the bottom of the row base cooler unit to the floor and apply foam seal as needed to ensure a tight fit.

  10. Insert Floor Seal Assembly

    Slide the floor seal assembly between the floor and the row base cooler unit, ensuring it forms a complete seal to prevent air loss.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.