Mersen STXH120P07 Mersen Surge-Trap STXH120P07: Type 1 SPD for 120/240VAC split-phase. Features TPMOV®…
Alternate Item Number: STXH120P07
UPC: 782001512354
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- UL Type 1 Surge Protective Device (SPD) for 120/240VAC split-phase systems
- Features advanced TPMOV® technology for reliable surge suppression
- UL Listed and UL1449 5th Edition compliant
- Compact NEMA 4X enclosure suitable for AC disconnects and HVAC units
- 3-mode protection (L-N, L-L) with LED status indicator
Specifications
Application | Residential Panels HVAC systems Pool and Spa equipment |
Application | Any 120/240VAC split phase application HVAC applications Direct mounting to air condition disconnect switches |
Connection | Pre-wired |
Frequency Rating | 50/60 HZ |
Material | Polycarbonate |
Mounting | Panel Mount |
Operating Temperature, Maximum | 185 F |
Operating Temperature, Maximum | 85 C |
Operating Temperature, Minimum | -40 F |
Operating Temperature, Minimum | -40 C |
Phase | 1 |
Series | STXH |
Size | 3.2 x 1.85 x 3.22;81.28 x 46.99 x 81.788 in;mm |
Special Features | Mersen TPMOV Technology – does not require additional overcurrent protection Compact footprint for seamless integration with AC Disconnect Switches NEMA 4X enclosure for outdoor or indoor use Fits 1/2" knockouts with 18" leads for easy installation Up to 3 Modes of Protection (L-N, L-L, and L-G) Bright LED status indicator, visible from side profile through clear cover 3-year manufacturer’s warranty, plus up to 25k connected equipment warranty (For details see Warranty Statement) |
Standard | ANSI/UL 1449 5th Edition, Type 1 SPD, File E210793 CSA C22.2, Type 1 SPD ANSI/IEEE C62.41.1, C62.41.2, C62.45 UL96A Lightning Protection RoHS Compliant |
Type | NEMA UL CSA TYPE 1 |
Type of Indicators | LED |
UL SPD Type | Type 1 |
Voltage Rating | 120/240 Vac |
Package Dimensions (L x W x H) | 3.2 in x 1.85 in x 3.22 in |
Package Dimensions (L x W x H) | 81.28 mm x 46.99 mm x 81.788 mm |
Package Weight (Imperial) | 0.800 lb |
Package Weight (Metric) | 0.363 kg |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What is the STXH series UL listing and compliance?
The Surge-Trap STXH series is UL listed as a Type 1 SPD and fully compliant with UL1449 5th Edition.
What voltage applications is the STXH series suitable for?
The STXH series is suitable for any 120/240VAC split phase application.
What technology does the STXH series use for surge protection?
The STXH series is equipped with Mersen's TPMOV technology for surge protection.
What is the operating temperature range for Mersen Surge-Trap devices?
Mersen Surge-Trap devices have an operating and storage temperature range of -40ºF (-40ºC) to +185ºF (85ºC).
What is the response time for Mersen Surge-Trap devices?
The response time for Mersen Surge-Trap devices is less than 1 nanosecond per phase.
What is the nominal discharge current for the STXT and STXP series?
The nominal discharge current (In) for the STXT and STXP series is 20kA using an 8x20 μs waveform.
What is the Short Circuit Current Rating (SCCR) for STXT and STXP series?
The Short Circuit Current Rating (SCCR) for the STXT and STXP series is 200kA.
What are the available surge current ratings for the STZ series?
The STZ series offers surge current ratings of 100, 150, 200, 300, and 450kA.
What is the warranty period for the STZ series?
The Surge-Trap STZ Series comes with a 15-year product warranty.
What is the warranty period for the STXT and STXP series?
The Surge-Trap STXT and STXP Series have a 10-year manufacturer's warranty.
How to Install the STXH120P07 Surge Protective Device (SPD)
Installation guide for mounting and wiring the STXH120P07 Surge Protective Device (SPD).
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers
Supplies needed:
Mounting screws, Terminal connectors, Watertight fittings (for outdoor applications)
- Verify System Compatibility
Confirm that the system voltage and configuration match the SPD's voltage and configuration. Refer to the product's nameplate or datasheet for specific values.
- De-energize Equipment
Turn off all power supplying the equipment. Verify that the equipment and all power sources are de-energized before proceeding. Follow safe electrical work practices and use appropriate PPE.
- Determine Mounting Location
Select a mounting location for the SPD. It should be as close to the equipment as possible, with leads kept straight and short. If using a circuit breaker, identify its location (a 30A breaker is recommended). Position the SPD so the LED status indicator is visible.
- Mount the SPD
Mount the STXH120P07 Surge Protective Device in the determined location. For outdoor applications, ensure watertight fittings are used to maintain the NEMA 4X rating.
- Make Electrical Connections
Make the electrical connections to the SPD. For optimal performance, trim the leads to the shortest possible length, avoiding loops, coils, or sharp bends. Connect the SPD in parallel. Refer to the wiring diagram and ensure proper grounding (XON-G bonding at the upstream transformer).
- Energize and Verify Operation
Energize the system and confirm the proper operation of the green LED status indicator. A green LED indicates the unit is functioning correctly. If the LED is off, the unit may be damaged, the circuit may be de-energized, or the SPD leads may be disconnected.
Frequently Asked Questions about Mersen
What industries and applications are Mersen products used for?
Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.
What are the main product lines offered by Mersen?
Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.
What are the key features of Mersen products?
Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.
What environmental ratings do Mersen products have?
Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.
What accessories are available for Mersen products?
Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.
How are Mersen products typically installed?
Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.
What certifications and standards do Mersen products comply with?
Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.
What technical support does Mersen offer?
Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.