Meltric 44-49003-P80 - INLET/ANGLE ADAPTER
Meltric

44-49003-P80

UPC: 784474134897


Documents & Media
BrochureTechnical DrawingInstallation InstructionsLine Drawing

Contact for Pricing

Overview

The Meltric 44-49003-P80 is a Size S, black, poly inlet/angle adapter designed for robust industrial electrical connections. This adapter boasts a substantial 600 Ampere current rating and a 600 Volt AC voltage rating, operating at a standard 60 Hz frequency. Engineered for superior environmental protection, it meets both IP66 and IP67 ingress protection standards, ensuring effective resistance against dust and water immersion. The NEMA rating of 600 further signifies its suitability for demanding industrial environments. This L3 pole configuration adapter is manufactured by Meltric, a trusted name in industrial electrical components. Its durable poly construction and specific size designation make it a reliable choice for applications requiring a 45-degree angle connection point, facilitating efficient cable management and installation in tight spaces. The Meltric 44-49003-P80 is ideal for power distribution systems where reliable, protected connections are paramount. Its specifications align with heavy-duty industrial requirements, providing a secure and durable interface for electrical equipment.
  • Meltric SKU: 44-49003-P80
  • Size S, Black Poly Inlet/Angle Adapter
  • 600 Ampere Current Rating
  • 600 Volt AC Voltage Rating
  • IP66/IP67 Rated for superior environmental protection
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the maximum amperage for this product?

The maximum amperage for this product is 600 A under CSA and NOM listings, and up to 800 A for IEC listings.

What is the maximum voltage rating?

The maximum voltage rating is 600 VAC under CSA and NOM listings, and up to 1000 VAC/1500 VDC for IEC listings.

What is the operating temperature range?

The operating temperature range for the device is a minimum of -15°F and a maximum of 140°F.

What environmental protection rating does the device have?

The device has an environmental protection rating of IP66/IP67 when mated.

Can this device be connected or disconnected under load?

No, the mechanical interlock and integral pilot circuit switch prevent connection and disconnection under load for safety.

What is the wiring capacity for this product?

The wiring capacity ranges from a minimum of 2/0 to a maximum of 777 MCM.

What is the standard cable range for plugs and connectors?

Plugs and connectors come standard with a .750-.875 inch cable range. Other sizes are available.

What type of contact material is used?

The device uses silver, butt-style contact technology, which maximizes performance and durability, withstanding at least 2000 operations.

Is this device suitable for current interruption?

No, the device is explicitly rated as "Not for Current Interrupting."

What are the horsepower ratings for this device?

The device has a 3-phase horsepower rating of 500 hp, specifically when auxiliary pilots are wired to control the motor control circuit.

How to Install the SP Series High-Amperage Plug and Receptacle

This guide provides step-by-step instructions for safely installing and wiring the SP series high-amperage plug and receptacle system.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Wrench (3/4 inch)

Supplies needed:

Mounting screws, Terminal connectors, Cable gland, Gaskets

  1. Disconnect Power

    Before starting the installation, ensure that all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.

  2. Mount the Receptacle

    Secure the receptacle to the mounting surface using the provided mounting screws. Ensure that the receptacle is level and that watertight seals are used to maintain IP66/IP67 protection.

  3. Connect the Main Conductors

    Use a flexible cable rated between 2/0 and 777 MCM. Attach the conductors to the terminals using either threaded or crimped lugs. Tighten the connections to the specified torque of 30 ft-lbs (40 N.m) using a 3/4 inch wrench.

  4. Wire the Pilot Contacts

    Connect the auxiliary/pilot contact leads in series within the power control circuit as per the wiring diagram provided in the documentation.

  5. Attach the Handle

    Insert the cable through the cable gland and handle before tightening the phase conductor. Assemble the handle using the screws and gasket provided.

  6. Verify Connections

    Use a multimeter to verify that all connections are secure and that there are no short circuits before restoring power.

  7. Test the System

    Once power is restored, test the system by inserting the plug into the receptacle until a 'click' is heard, indicating a secure connection.

Frequently Asked Questions about Meltric

What certifications and standards do Meltric products comply with?

Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.

What are the key features of Meltric products?

Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.

What environmental ratings do Meltric products have?

Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).

What industries and applications are Meltric products used for?

Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.

What technical support does Meltric offer?

Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.

What are the main product lines offered by Meltric?

Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.

What accessories are available for Meltric products?

Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.

How are Meltric products typically installed?

Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.

What is Meltric's warranty policy?

Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.