The Macromatic VWKP110D is a voltage band (window) protector designed to safeguard sensitive equipment from damaging over-voltage and under-voltage conditions. Part of Macromatic’s VWKP Series, this device monitors AC voltage within a user-defined range, triggering protective actions when voltages exceed or fall below set thresholds. It features adjustable over-voltage (120-150V AC) and under-voltage (90-120V AC) settings, along with a configurable time delay for nuisance trip prevention. The VWKP110D is ideal for protecting motors, drives, and control systems in industrial panels where stable voltage is critical. Manufactured by Macromatic, a trusted name in industrial protection relays, this plug-in module integrates seamlessly into 110V AC systems.
  • Monitors 110V AC systems for over-voltage (120-150V AC) and under-voltage (90-120V AC)
  • User-adjustable voltage thresholds and time delay settings
  • Plug-in design for easy panel mounting
  • LED indicators for supply power (green) and operation status (red)
  • Part of Macromatic’s VWKP Series for industrial voltage protection
CM-MPS.21S THREE-PHASE MON.

1SVR730885R3300

CM-MPS.21S THREE-PHASE MON.
The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.

PLM9405

The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.
Three Phase Monitor Relay; DIN-Mount; 190-500V; 10A DPDT; Phase Loss; Reversal; Unbalance; Under/Over Voltage

PMDU

Three Phase Monitor Relay; DIN-Mount; 190-500V; 10A DPDT; Phase Loss; Reversal; Unbalance; Under/Over Voltage
Relay 460V 3 Phase Monitor

18883000015

Relay 460V 3 Phase Monitor
The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation: The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault.

PLS480A

The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation: The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault.
The PLR Series provides a cost effective means of preventing 3-phase motor startup during adverse voltage conditions. Proper A-B-C sequence must occur in order for the PLR’s output contacts to energize. In addition, the relay will not energize when an undervoltage or phase loss condition is present. The PLR protects a motor against undervoltage operation. The adjustment knob sets the undervoltage trip point. Operation: The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage must be sensed for a continuous dropout delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied.

PLR240A

The PLR Series provides a cost effective means of preventing 3-phase motor startup during adverse voltage conditions. Proper A-B-C sequence must occur in order for the PLR’s output contacts to energize. In addition, the relay will not energize when an undervoltage or phase loss condition is present. The PLR protects a motor against undervoltage operation. The adjustment knob sets the undervoltage trip point. Operation: The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage must be sensed for a continuous dropout delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied.
The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation: The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault.

PLS240A

The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation: The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault.
The DLMU Series is a universal voltage, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required. See datasheet for operation details.

DLMUBRAAA

The DLMU Series is a universal voltage, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required. See datasheet for operation details.

Frequently Asked Questions about Macromatic

What certifications and standards do Macromatic products comply with?

Macromatic products are certified with ULus and cULus approvals for use in the United States and Canada, covering a wide range of industrial control products. Their product line includes UL-listed devices for various voltage ranges (120V, 208-277V) and NEMA enclosure types, ensuring compliance with North American industrial standards.

What industries and applications are Macromatic products used for?

Macromatic products are used across multiple critical industrial sectors, including water/wastewater, pump and motor control, irrigation, oil and gas, HVACR, material handling, lifts and elevators, and other systems requiring process control and protection. Their industrial control products deliver high-quality monitoring, control, and protection solutions for electrical processes and equipment fault protection.

What technical support does Macromatic offer?

Macromatic offers comprehensive technical support through multiple channels, including a dedicated online Technical Resource Center at macromatic.com/technical-support and direct contact with technical advisors. Their support includes engineering assistance for unique applications, help with product selection, custom-engineered solutions, and troubleshooting for product setup. Customers can reach out via their website contact form or contact their technical team directly to get expert guidance on their industrial control products.

What are the main product lines offered by Macromatic?

Macromatic offers a comprehensive range of industrial control, monitoring, and protection products across multiple product lines, including Alternating Relays, Current Sensing Relays, General Purpose Relays, Intrinsically Safe Barrier Relays, Liquid Level Control Relays, Voltage Monitor Relays, and Time Delay Relays. These products serve critical applications in industries such as water/wastewater, pump and motor control, irrigation, oil and gas, HVACR, material handling, and lift systems.

What are the key features of Macromatic products?

Macromatic products feature innovative industrial control solutions with key characteristics including precise time-based control, compact design, and comprehensive protection capabilities. Their product lines cover voltage monitoring, time delay relays, and control products for multiple industries like water/wastewater, pump and motor control, oil and gas, and HVACR. Standout features include space-saving designs, multiple time delay functions, voltage band protection, and customizable solutions with quick prototype turnaround.

What accessories are available for Macromatic products?

Macromatic offers a comprehensive line of accessories for their industrial control products, including industry-standard sockets (8-pin, 11-pin octal, and 12-pin square), back-mounted sockets for panel mounting, retainers, hold-down springs, terminal covers, and replacement terminals. These accessories are designed to simplify relay installation, replacement, and provide additional mounting and protection options for Macromatic products.

How are Macromatic products typically installed?

Macromatic products are typically installed using industry-standard 8-pin and 11-pin octal sockets, as well as 12-pin square sockets that simplify relay installation. These sockets allow for easy mounting, with back-mounted socket options enabling flange-style enclosures to be panel mounted. Additional installation accessories like retainers, hold-down springs, terminal covers, and replacement terminals are available to support precise and secure product installation.

What communication protocols do Macromatic products support?

Macromatic communication modules support multiple industrial communication protocols, including Modbus RTU, Modbus TCP/IP, PROFIBUS, PROFINET, DeviceNet, EtherNet/IP, and IEC 61850. These protocols enable flexible network integration across industrial automation systems, providing comprehensive connectivity and communication capabilities for diverse industrial applications.

What environmental ratings do Macromatic products have?

Macromatic products feature robust environmental ratings across multiple NEMA and IP standards. Most product lines offer NEMA Type 3R, 4, and 4X ratings, with specific models providing protection against dust, water, and corrosion for both indoor and outdoor applications. Select product series like DS20, DS30, DR30, and DR50 come standard as 3R with optional 4X upgrades available.