Littelfuse PLM6502 - The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.
Littelfuse

PLM6502

Alternate Item Number: PLM6502

UPC: 079458997903


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Overview

The Littelfuse PLM6502 3-phase voltage monitor provides continuous protection for industrial electrical systems operating between 200-600VAC at 50/60Hz. This advanced monitor supports both delta and wye configurations without requiring a neutral connection, simplifying installation in existing systems. The microcontroller-based circuit continuously monitors all three phases for undervoltage, voltage unbalance, phase loss, and phase reversal, even when regenerated voltages are present. The output relay energizes and the LED glows green when all voltages are within acceptable limits and the phase sequence is correct. If a fault is detected, the relay de-energizes after a continuous trip delay period, with the LED flashing red during the delay and glowing red when de-energized. Phase reversal is indicated by a flashing green/red LED. The PLM6502 features field-adjustable voltage settings via a front-panel knob, allowing users to set the desired operating line voltage, which automatically configures the undervoltage trip point. The screw terminal connection ensures secure and straightforward wiring. Ideal for protecting industrial motors, pumps, compressors, and other critical equipment, the PLM6502 ensures operational reliability and prevents costly downtime. The device is housed in a compact enclosure suitable for DIN rail or panel mounting, making it a versatile solution for diverse industrial environments.
  • Continuously monitors all three phases for undervoltage, voltage unbalance, phase loss, and phase reversal
  • Supports both delta and wye systems without requiring a neutral connection
  • Field-adjustable voltage settings via front-panel knob for 200-600VAC systems
  • Output relay energizes when conditions are acceptable (green LED), de-energizes on faults (red LED)
  • Compact design for DIN rail or panel mounting with screw terminals

Specifications

Brand Name
Littelfuse
Connection Type
Screw Terminal
Frequency
50/60Hz
Operating Temperature
-40 to 60 F
Operating Temperature, Maximum
60 F
Operating Temperature, Minimum
-40 F
Series
PLM
Series
PLM Series
Special Features
10Y WARR
Standard
CE/UR/CSA
Sub Brand
SSAC
Voltage Rating
200-600VAC
Package Dimensions (L x W x H)
1.78 IN x 2.39 IN x 3.2 IN
Package Dimensions (L x W x H)
45.2 mm x 60.7 mm x 81.3 mm
The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.

PLM6405

The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.
The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.

PLM9502

The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.
The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.

PLM9405

The PLM Series is a 3-phase voltage monitor that continuously monitors each of the three phases. Monitors both delta and wye systems and no connection to neutral is required. The microcontroller circuit design protects against undervoltage, voltage unbalance, phase loss and phase reversal. Protection is assured when regenerated voltages are present. Operation: The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.
The PLMU11 continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation from 200 to 480 VAC and standard base connection allows the PLMU11 to replace hundreds of competitive part numbers. Operation: Upon application of power, a 0.6s random start delay begins and the PLMU11 measures the voltage levels and line frequency and selects the voltage range. The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. LED flashes green during trip delay, glows red when output de-energizes. undervoltage, overvoltage, and voltage unbalance must be sensed for continuous trip delay before the relay de-energizes. Reenergization is automatic upon fault correction. The output relay will not energize if a fault condition is sensed as 3-phase input voltage is applied. The LED alternately flashes red/green when phase reversal is sensed. Line voltage is selected with the knob, setting the over and under voltage trip points. Voltage range is automatically selected by the microcontroller.

PLMU11

The PLMU11 continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation from 200 to 480 VAC and standard base connection allows the PLMU11 to replace hundreds of competitive part numbers. Operation: Upon application of power, a 0.6s random start delay begins and the PLMU11 measures the voltage levels and line frequency and selects the voltage range. The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. LED flashes green during trip delay, glows red when output de-energizes. undervoltage, overvoltage, and voltage unbalance must be sensed for continuous trip delay before the relay de-energizes. Reenergization is automatic upon fault correction. The output relay will not energize if a fault condition is sensed as 3-phase input voltage is applied. The LED alternately flashes red/green when phase reversal is sensed. Line voltage is selected with the knob, setting the over and under voltage trip points. Voltage range is automatically selected by the microcontroller.
The DLMU Series is a universal voltage, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required. See datasheet for operation details.

DLMUBNAAN

The DLMU Series is a universal voltage, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required. See datasheet for operation details.

Frequently Asked Questions about Littelfuse

What certifications and standards do Littelfuse products comply with?

Littelfuse products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Customers can verify specific product certifications by consulting individual product datasheets on Littelfuse.com, which provide comprehensive details about standards compliance for each component.

What industries and applications are Littelfuse products used for?

Littelfuse products are critical for electrical protection and safety across multiple industrial sectors, including manufacturing, automation, power distribution, and electrical control systems. Their comprehensive product portfolio serves industries that require robust electrical protection, including motor and pump applications, solar installations, programmable logic controllers (PLCs), electrical switch panels, and critical infrastructure environments. Key product lines protect against overcurrent, voltage transients, ground faults, and temperature-related electrical risks, ensuring equipment safety and operational reliability.

What technical support does Littelfuse offer?

Littelfuse offers comprehensive technical support through multiple channels. Their Technical Hotline (800-TEC-FUSE) provides direct access to engineers who can help identify issues and recommend solutions. Additionally, Littelfuse offers extensive online Technical Resources at Littelfuse.com, including datasheets, product manuals, whitepapers, application guides, and online design tools. Their experienced product and application engineers also provide step-by-step support from design to installation.

What are the main product lines offered by Littelfuse?

Littelfuse offers comprehensive industrial protection and control product lines, including fuses, fuse holders, protection relays, temperature sensors, and electrical safety components. Their key product categories span surge protective devices, custom OEM products, electrical switch panels, medium voltage fuses, ground-fault protection relays, motor and pump protection devices, and temperature sensors. These products are designed to minimize electrical safety hazards, limit equipment damage, improve productivity, and safeguard personnel from electrical faults.

What are the key features of Littelfuse products?

Littelfuse products feature exceptional circuit protection technologies with key characteristics including UL/IEC safety standard compliance, low internal resistance, and advanced protective capabilities across multiple product lines. Their components provide critical protection for industrial systems, offering features like overcurrent protection, voltage transient suppression, and resettable protection devices with ultra-low resistance and compact designs. Key product lines include fuses, metal oxide varistors (MOVs), TVS diodes, PolySwitch devices, and specialized electronic protection components that enhance system reliability and safety.

What environmental ratings do Littelfuse products have?

Littelfuse products feature comprehensive environmental ratings, including NEMA Type 1, 2, 3, 3R, 4/4X, 12, and 13 certifications, as well as IP65 protection. These ratings ensure superior protection in diverse industrial environments, with an operating temperature range of -40°F to +131°F (-40°C to +55°C). Many products also include UV-stabilized materials and neoprene gaskets for enhanced durability in outdoor and challenging conditions.

What accessories are available for Littelfuse products?

Littelfuse offers several key accessories across their product lines, including fuse holders, voltage monitoring modules, and terminal connectors. Specific accessories include the LPSM003ZXID (indicating) and LPSM003Z (non-indicating) POWR-SAFE Dead Front fuse holders for Class CC and Midget-Style fuses, the VRM6048 voltage monitor accessory module, and female quick connect terminals (P1015 series) in various wire gauge sizes. These accessories are designed to enhance protection, monitoring, and connectivity for Littelfuse electrical components.

What is Littelfuse's warranty policy?

Littelfuse provides comprehensive warranty details on their official website at www.littelfuse.com/warranty. Customers should visit this page to review the specific warranty terms and conditions for their specific product lines. For direct warranty support or questions, customers can contact Littelfuse Technical Support at 1-800-TEC-FUSE or email [email protected].

What communication protocols do Littelfuse products support?

Littelfuse supports a comprehensive range of industrial communication protocols, including PROFIBUS, PROFINET, EtherNet/IP, DeviceNet, Modbus RTU, and CANopen. Our products provide flexible connectivity solutions across multiple industrial automation platforms, enabling seamless integration with various control systems and network architectures.

How are Littelfuse products typically installed?

Littelfuse products are typically installed using specialized mounting hardware like fuse holders, blocks, and panels designed for specific industrial applications. The POWR-SAFE Dead Front holders, for example, provide optimum protection for Class CC and Midget-Style fuses, supporting installations up to 600 VAC/DC. Installation often involves using precision terminals with strain relief, such as 0.25 in. female quick connect terminals, to ensure secure and safe electrical connections in industrial control systems.