Littelfuse FS590 - The FS500 Series flash rate is adjustable from 10 to 100 FPM. A locknut is provided to hold selected flash rate. The long-life electronic circuit combined with a quality electromechanical relay provides flexibility and reliability in most applications. Operation: Upon application of input voltage, the output relay is energized and the ON time begins. At the end of the ON time, the output relay de-energizes and the OFF time begins. At the end of the OFF time, the output is energized and the cycle repeats as long as input voltage is applied. Reset: Removing input voltage resets the output and the sequence.
Littelfuse

FS590

Alternate Item Number: FS590

UPC: 079458993592


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Overview

The Littelfuse FS590 (SKU: FS590) is an ON/OFF recycling flasher designed for industrial applications requiring precise timing control. This electromechanical relay features an adjustable flash rate from 10 to 100 flashes per minute (FPM), with a locknut to secure your selected setting. Its robust construction combines long-life electronic circuitry with a high-quality electromechanical relay, ensuring both flexibility and reliability in operation. The FS590 operates by energizing its output relay upon application of input voltage, initiating the ON time. Once the ON time completes, the output relay de-energizes, starting the OFF time. This cycle repeats continuously as long as input voltage is applied. Removing input voltage resets the output and sequence. Key specifications include an industry-standard octal plug connection, eliminating the need for specialized connectors. The DPDT isolated output contacts are rated for 10A resistive at 120/240VAC and 28VDC, and 1/3 hp at 120/240VAC, enabling control of both AC and DC loads. For DC inputs, reverse polarity protection is included. The unit provides an isolation voltage of ≥1500V RMS from input to output and operates reliably within a temperature range of -20° to 60°C. Ideal for signaling systems, industrial automation, and process control applications, the FS590 is a dependable solution where adjustable and consistent flashing is essential. Compatible accessories for mounting and integration include the BZ1 Front Panel Mount Kit and the NDS-8 Octal 8-pin Socket. Dimensions are H 91.6 mm (3.62”), W 60.7 mm (2.39”), D 45.2 mm (1.78”).
  • Adjustable flash rate from 10 to 100 FPM with locknut to secure settings
  • DPDT isolated output contacts rated 10A resistive at 120/240VAC & 28VDC, 1/3 hp at 120/240VAC
  • Industry-standard octal plug connection for easy installation
  • Reverse polarity protection for DC inputs
  • Operating temperature range: -20° to 60°C

Specifications

Brand Name
Littelfuse
Connection
Plug-in socket
Mounting
Plug-in socket Mount
Operating Temperature
-20 to 60 F
Operating Temperature, Maximum
60 F
Operating Temperature, Minimum
-20 F
Special Features
10Y WARR
Standard
CE/UR/CSA
Sub Brand
SSAC
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS126RC

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS127

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The PCR Series of photo control is a combination of precision electronic circuitry, electromechanical output, and unique molded plastic housing. Designed and built to meet the demands of the most rigorous requirement of tower and obstruction lighting control, each unit is factory calibrated to meet FAA and FCC specifications. Electronic circuit, output contactor, and terminal block are all contained within front plastic housing. Edge support molded into the bottom edge of housing allows easy wiring of new and existing installations. Available with or without cast aluminum junction box. Operation: When the amount of light sensed falls below the actuation level for energization, the output relay energizes. Conversely, when the amount rises above the actuation level for de-energization, the output relay de-energizes.

PCR11

The PCR Series of photo control is a combination of precision electronic circuitry, electromechanical output, and unique molded plastic housing. Designed and built to meet the demands of the most rigorous requirement of tower and obstruction lighting control, each unit is factory calibrated to meet FAA and FCC specifications. Electronic circuit, output contactor, and terminal block are all contained within front plastic housing. Edge support molded into the bottom edge of housing allows easy wiring of new and existing installations. Available with or without cast aluminum junction box. Operation: When the amount of light sensed falls below the actuation level for energization, the output relay energizes. Conversely, when the amount rises above the actuation level for de-energization, the output relay de-energizes.
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS146

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The PHS230A6 relay provides phase control protection with input voltage at 230 V ac and output load rating at steady state (100% on) of 6 A; inrush of 60 A.

PHS230A6

The PHS230A6 relay provides phase control protection with input voltage at 230 V ac and output load rating at steady state (100% on) of 6 A; inrush of 60 A.
The PHS120A6 relay provides phase control protection with input voltage at 120 V ac and output load rating at steady state (100% on) of 6 A; inrush of 60 A.

PHS120A6

The PHS120A6 relay provides phase control protection with input voltage at 120 V ac and output load rating at steady state (100% on) of 6 A; inrush of 60 A.
The FS100 Series (medium power) may be used to control inductive, incandescent, or resistive loads. Input voltages of 24, 120, or 230VAC are available. Fixed flash rates in stock range from 30, 50, 60, and 90 FPM, with custom flash rates ranging from 10 to 300 FPM. Encapsulation provides protection against shock, vibration, and humidity. This group of solid-state flashers has proven reliability with years of use throughout the world.

FS143

The FS100 Series (medium power) may be used to control inductive, incandescent, or resistive loads. Input voltages of 24, 120, or 230VAC are available. Fixed flash rates in stock range from 30, 50, 60, and 90 FPM, with custom flash rates ranging from 10 to 300 FPM. Encapsulation provides protection against shock, vibration, and humidity. This group of solid-state flashers has proven reliability with years of use throughout the world.
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS165-30T

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The FS200 Series may be used to control inductive, incandescent, or resistive loads. Factory fixed flash rate of 45 or 90 FPM or may be ordered with a fixed custom flash rate ranging from 10 to 180 FPM. Encapsulation provides protection against shock, vibration, and humidity. Uniform performance, high inrush current capability, and low RFI, make this series ideal for general industrial applications. Operation: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS224

The FS200 Series may be used to control inductive, incandescent, or resistive loads. Factory fixed flash rate of 45 or 90 FPM or may be ordered with a fixed custom flash rate ranging from 10 to 180 FPM. Encapsulation provides protection against shock, vibration, and humidity. Uniform performance, high inrush current capability, and low RFI, make this series ideal for general industrial applications. Operation: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The FS300 Series of solid-state flashers were specifically designed to operate lamp loads. Their two-terminal series connection feature makes installation easy. The high immunity to line noise and transients makes the FS300 Series ideal for moving vehicle applications. All solid-state construction means reliability and long life. The FS300 Series offers a factory fixed flash rate of 75 FPM or may be ordered with a fixed, custom flash rate ranging from 60 to 150 FPM. Operation: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS324

The FS300 Series of solid-state flashers were specifically designed to operate lamp loads. Their two-terminal series connection feature makes installation easy. The high immunity to line noise and transients makes the FS300 Series ideal for moving vehicle applications. All solid-state construction means reliability and long life. The FS300 Series offers a factory fixed flash rate of 75 FPM or may be ordered with a fixed, custom flash rate ranging from 60 to 150 FPM. Operation: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS155-30T

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

FS126

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

Frequently Asked Questions about Littelfuse

What certifications and standards do Littelfuse products comply with?

Littelfuse products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Customers can verify specific product certifications by consulting individual product datasheets on Littelfuse.com, which provide comprehensive details about standards compliance for each component.

What industries and applications are Littelfuse products used for?

Littelfuse products are critical for electrical protection and safety across multiple industrial sectors, including manufacturing, automation, power distribution, and electrical control systems. Their comprehensive product portfolio serves industries that require robust electrical protection, including motor and pump applications, solar installations, programmable logic controllers (PLCs), electrical switch panels, and critical infrastructure environments. Key product lines protect against overcurrent, voltage transients, ground faults, and temperature-related electrical risks, ensuring equipment safety and operational reliability.

What technical support does Littelfuse offer?

Littelfuse offers comprehensive technical support through multiple channels. Their Technical Hotline (800-TEC-FUSE) provides direct access to engineers who can help identify issues and recommend solutions. Additionally, Littelfuse offers extensive online Technical Resources at Littelfuse.com, including datasheets, product manuals, whitepapers, application guides, and online design tools. Their experienced product and application engineers also provide step-by-step support from design to installation.

What are the main product lines offered by Littelfuse?

Littelfuse offers comprehensive industrial protection and control product lines, including fuses, fuse holders, protection relays, temperature sensors, and electrical safety components. Their key product categories span surge protective devices, custom OEM products, electrical switch panels, medium voltage fuses, ground-fault protection relays, motor and pump protection devices, and temperature sensors. These products are designed to minimize electrical safety hazards, limit equipment damage, improve productivity, and safeguard personnel from electrical faults.

What are the key features of Littelfuse products?

Littelfuse products feature exceptional circuit protection technologies with key characteristics including UL/IEC safety standard compliance, low internal resistance, and advanced protective capabilities across multiple product lines. Their components provide critical protection for industrial systems, offering features like overcurrent protection, voltage transient suppression, and resettable protection devices with ultra-low resistance and compact designs. Key product lines include fuses, metal oxide varistors (MOVs), TVS diodes, PolySwitch devices, and specialized electronic protection components that enhance system reliability and safety.

What environmental ratings do Littelfuse products have?

Littelfuse products feature comprehensive environmental ratings, including NEMA Type 1, 2, 3, 3R, 4/4X, 12, and 13 certifications, as well as IP65 protection. These ratings ensure superior protection in diverse industrial environments, with an operating temperature range of -40°F to +131°F (-40°C to +55°C). Many products also include UV-stabilized materials and neoprene gaskets for enhanced durability in outdoor and challenging conditions.

What accessories are available for Littelfuse products?

Littelfuse offers several key accessories across their product lines, including fuse holders, voltage monitoring modules, and terminal connectors. Specific accessories include the LPSM003ZXID (indicating) and LPSM003Z (non-indicating) POWR-SAFE Dead Front fuse holders for Class CC and Midget-Style fuses, the VRM6048 voltage monitor accessory module, and female quick connect terminals (P1015 series) in various wire gauge sizes. These accessories are designed to enhance protection, monitoring, and connectivity for Littelfuse electrical components.

What is Littelfuse's warranty policy?

Littelfuse provides comprehensive warranty details on their official website at www.littelfuse.com/warranty. Customers should visit this page to review the specific warranty terms and conditions for their specific product lines. For direct warranty support or questions, customers can contact Littelfuse Technical Support at 1-800-TEC-FUSE or email [email protected].

What communication protocols do Littelfuse products support?

Littelfuse supports a comprehensive range of industrial communication protocols, including PROFIBUS, PROFINET, EtherNet/IP, DeviceNet, Modbus RTU, and CANopen. Our products provide flexible connectivity solutions across multiple industrial automation platforms, enabling seamless integration with various control systems and network architectures.

How are Littelfuse products typically installed?

Littelfuse products are typically installed using specialized mounting hardware like fuse holders, blocks, and panels designed for specific industrial applications. The POWR-SAFE Dead Front holders, for example, provide optimum protection for Class CC and Midget-Style fuses, supporting installations up to 600 VAC/DC. Installation often involves using precision terminals with strain relief, such as 0.25 in. female quick connect terminals, to ensure secure and safe electrical connections in industrial control systems.