Authorized Hammond Power Distributor
Hammond Power WAHF1D100F-T - Active Harmonic Filter 240V 100A 60Hz MDB/TCP open style

Hammond Power WAHF1D100F-T Active Harmonic Filter 240V 100A 60Hz MDB/TCP open style

UPC: 803423160920


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power WAHF1D100F-T is an Active Harmonic Filter designed for 240V systems operating at 60Hz. This open-style unit, with a current rating of 100A, is engineered to mitigate harmonic distortion in industrial electrical systems. Harmonic distortion, often caused by non-linear loads like variable frequency drives, rectifiers, and switching power supplies, can lead to overheating of transformers and conductors, nuisance tripping of circuit breakers, and reduced equipment lifespan. The WAHF1D100F-T actively monitors the current waveform and injects compensating currents to cancel out harmonic components, thereby improving power quality and system reliability. Its open-style construction allows for flexible integration into existing control panels or electrical enclosures, requiring careful consideration for environmental protection. Manufactured in the USA by Hammond Power, this filter is a direct solution for improving the efficiency and stability of power distribution networks. The MDB/TCP designation suggests specific communication or control interface capabilities, though detailed specifications for these features are not provided in the catalog description. This unit is suitable for applications where maintaining a clean power sine wave is critical to operational performance and equipment longevity.
  • Active Harmonic Filter for 240V systems
  • 100A current rating
  • 60Hz operating frequency
  • MDB/TCP communication/control interface
  • Open-style construction for flexible integration

Specifications

Ambient Temperature
0°C to 40°C Deg C
Application
Chemical Processing, Data Centers, HVAC, Material Handling, Mining, Oil & Gas, Pulp & Paper, Hospitals, Wastewater
Communication Option
Modbus TCP
Enclosure
Open Frame
Frequency Rating
60 HZ
Height
45 in
Length
12.7 in
Mounting
Wall mount
Special Features
Active Filter for harmonic mitigation and power factor correction. Options include Ethernet, Ethernet IP, and Modbus communication options.
Standard
cUL
Type
Filter > Active Harmonic Filter
Width
16.9 IN
Active Harmonic Filter 240V 100A 60Hz ETH open style

WAHF1D100F

Active Harmonic Filter 240V 100A 60Hz ETH open style
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
Active Harmonic Filter 240V 150A 60Hz MDB/TCP open style

WAHF1D150F-T

Active Harmonic Filter 240V 150A 60Hz MDB/TCP open style
Active Harmonic Filter 240V 300A 60Hz MDB/TCP open style

WAHF1D300F-T

Active Harmonic Filter 240V 300A 60Hz MDB/TCP open style
Active Harmonic Filter 240V 200A 60Hz MDB/TCP open style

WAHF1D200F-T

Active Harmonic Filter 240V 200A 60Hz MDB/TCP open style
Active Harmonic Filter 480V 200A 60Hz ETH type 1;used on 600V w/auto

WAHF1K200A-E6P1

Active Harmonic Filter 480V 200A 60Hz ETH type 1;used on 600V w/auto
Active Harmonic Filter 480V 150A 60Hz MDB/TCP type 1;used on 600V w/auto

WAHF1K150A-T6P1

Active Harmonic Filter 480V 150A 60Hz MDB/TCP type 1;used on 600V w/auto
Active Harmonic Filter 240V 100A 60Hz ETH/IP type 1

WAHF1D100A-I

Active Harmonic Filter 240V 100A 60Hz ETH/IP type 1

Frequently Asked Questions

What is the purpose of the HPS TruWave Active Harmonic Filter?

The AHF is designed to reduce total demand distortion (TDD) and total harmonic distortion (THD(V)) to levels less than 5%. It also corrects linear displacement and balances incoming three-phase current.

What input voltage options are available for the AHF?

The AHF can operate from an input voltage of 480, 240, or 208 VAC, with a tolerance of +12%, -15%, for 3-phase, 3-wire plus ground systems.

What information is displayed on the AHF's LCD touch screen?

The LCD displays power quality information like voltage, current, THD, harmonic current, KW, KVA, and PF, as well as system status and operating parameters.

How does the AHF handle overload conditions?

The AHF uses electronic current limiting to limit its output to 100% RMS of the system current rating and is designed to operate continuously under this condition.

What are the operating temperature and humidity ranges for the AHF?

The AHF operates in ambient temperatures from 0°C to 40°C and can tolerate humidity from 0 to 95% non-condensing.

How does the AHF record shutdown and reset events?

The AHF can record the last 1,856 reset events and 480 shutdown events, including date, time, and reason, with battery backup memory.

Can multiple AHF units be used together?

Yes, multiple systems can be installed in parallel, up to six units, if the required harmonic correction exceeds the maximum current rating of a single unit.

What types of enclosures are available for the AHF?

Systems rated 50-200 amps are in wall-mountable NEMA Type 1 enclosures. Systems rated 300 amps are in floor-mountable (freestanding) NEMA Type 1 enclosures.

What standards does the AHF comply with?

The AHF complies with standards such as ANSI/IEEE 519-2014, ANSI/IEEE C62.41-1991, CSA C.22.2 No. 14, and UL 508.

What is the efficiency rating of the AHF?

The AHF has an efficiency of no less than 98% at full load, with heat losses not exceeding 2% of the unit's KVAR rating.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.