Overview

The Hammond Power WAHF1D300F-T is an Active Harmonic Filter designed for industrial applications requiring power quality improvement. Operating at 240V and rated for 300A at 60Hz, this unit actively mitigates harmonic distortion in electrical systems. Its open-style construction allows for flexible integration into existing control panels or enclosures, providing efficient harmonic compensation without requiring a dedicated cabinet. This filter is crucial for maintaining system efficiency, preventing equipment malfunction, and ensuring compliance with power quality standards by injecting compensating currents to cancel out harmonic currents generated by non-linear loads. The WAHF1D300F-T is suitable for environments where variable frequency drives (VFDs), LED lighting, or other non-linear loads contribute to significant harmonic pollution. By reducing total harmonic distortion (THD), it helps extend the lifespan of sensitive electrical equipment, reduce energy losses, and improve overall system reliability. The MDB/TCP designation indicates its compatibility with specific control and data bus interfaces, facilitating advanced monitoring and control capabilities. This Hammond Power solution offers a direct approach to addressing harmonic issues, enhancing the performance and stability of your electrical infrastructure.
  • Active Harmonic Filtering for power quality improvement
  • 240V operating voltage
  • 300A current rating
  • 60Hz frequency operation
  • MDB/TCP open-style construction

Specifications

Ambient Temperature
0°C to 40°C Deg C
Application
Chemical Processing, Data Centers, HVAC, Material Handling, Mining, Oil & Gas, Pulp & Paper, Hospitals, Wastewater
Communication Option
Modbus TCP
Enclosure
Open Frame
Frequency Rating
60 HZ
Height
56 in
Length
13.7 in
Mounting
Floor Mount
Special Features
Active Filter for harmonic mitigation and power factor correction. Options include Ethernet, Ethernet IP, and Modbus communication options.
Standard
cUL
Type
Filter > Active Harmonic Filter
Width
27 in
Active Harmonic Filter 240V 300A 60Hz ETH open style

WAHF1D300F

Active Harmonic Filter 240V 300A 60Hz ETH open style
DigiBOX B-30 ND RS485 240V PC

USDBBB30ND0

DigiBOX B-30 ND RS485 240V PC
Active Harmonic Filter 240V 200A 60Hz MDB/TCP open style

WAHF1D200F-T

Active Harmonic Filter 240V 200A 60Hz MDB/TCP open style
Active Harmonic Filter 480V 200A 60Hz ETH type 1;used on 600V w/auto

WAHF1K200A-E6P1

Active Harmonic Filter 480V 200A 60Hz ETH type 1;used on 600V w/auto
Active Harmonic Filter 480V 150A 60Hz MDB/TCP type 1;used on 600V w/auto

WAHF1K150A-T6P1

Active Harmonic Filter 480V 150A 60Hz MDB/TCP type 1;used on 600V w/auto
Active Harmonic Filter 240V 100A 60Hz ETH/IP type 1

WAHF1D100A-I

Active Harmonic Filter 240V 100A 60Hz ETH/IP type 1
Active Harmonic Filter 240V 300A 60Hz MDB/TCP type 1

WAHF1D300A-T

Active Harmonic Filter 240V 300A 60Hz MDB/TCP type 1
Active Harmonic Filter 480V 150A 60Hz ETH/IP type 1;used on 600V w/auto

WAHF1K150A-I6P1

Active Harmonic Filter 480V 150A 60Hz ETH/IP type 1;used on 600V w/auto

Frequently Asked Questions

What is the primary function of the HPS TruWave Active Harmonic Filter?

The AHF is designed to reduce total demand distortion (TDD) and total harmonic distortion (THD(V)) to levels less than 5%, and can correct linear displacement and balance three-phase current.

What are the operating voltage and frequency ranges for the AHF?

The AHF operates from 480, 240, or 208 VAC, 3-phase, with a tolerance of +12%, -15%. It functions at 50 or 60 Hz, ±5 Hz.

What is the efficiency rating of the AHF?

The AHF efficiency is no less than 98% at full load, with heat losses not exceeding 2% of the unit's KVAR rating.

How does the AHF handle installations requiring more current correction than a single unit provides?

Multiple AHF units can be paralleled to achieve the required harmonic correction, with up to six systems connectable in parallel.

What information can be viewed on the AHF's LCD touch screen display?

The LCD touch screen displays power quality information (voltage, current, THD, harmonics, power factor), operating status, and various system parameters like temperatures and voltages.

What communication interfaces are available for the AHF?

The AHF features an Ethernet communications interface for configuration, diagnostics, and data collection. Optional Ethernet/IP or Modbus TCP modules are also available.

What type of enclosure is used for the AHF systems?

AHF systems are provided in NEMA Type 1 gasketed enclosures with air intake filters. Units rated 50-200 amps are wall-mountable, while 300 amp units are floor-mountable.

What environmental conditions are suitable for AHF operation?

The AHF operates in ambient temperatures from 0°C to 40°C and humidity from 0 to 95% non-condensing. It can operate up to 1000 M altitude, with de-rating at higher altitudes.

What are the storage temperature requirements for the AHF?

The AHF should be stored in its original packaging in a well-ventilated area protected from weather, moisture, and extreme temperatures, between -20°C and 60°C.

What safety features are included with the AHF?

The AHF includes a door interlocked disconnect switch that is lockable in the off position, and fuses provide redundant overload protection rated at 200,000 AIC.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.