Authorized Hammond Power Distributor
Hammond Power TE3A0075JJ - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 75kVA 460D-460Y/266V AL 60Hz 3R

Hammond Power TE3A0075JJ 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive…

UPC: 803423143459


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power TE3A0075JJ is a 75kVA, three-phase drive isolation transformer designed for energy efficiency and compliance with DOE2016 and NRCan 2019 standards. This transformer operates at 600V and features a 460D-460Y/266V configuration, utilizing aluminum windings for reliable performance. Its robust construction and adherence to energy efficiency regulations make it an ideal choice for industrial applications requiring clean power for motor drives. The transformer is built to withstand demanding operational conditions, ensuring consistent power delivery and protecting sensitive motor drive systems from electrical disturbances. Engineered in the USA, the TE3A0075JJ offers a dependable solution for power quality needs in various manufacturing and industrial settings. Its 3R enclosure provides protection suitable for indoor or outdoor installations where moderate protection from falling rain and sleet is required. The 60Hz frequency ensures compatibility with standard industrial power grids. This unit is specifically designed to isolate drive loads, reducing harmonic distortion and improving the overall efficiency and lifespan of motor control systems.
  • 75kVA, Three-Phase Drive Isolation Transformer
  • 600V Class, 460D-460Y/266V Configuration
  • DOE2016 and NRCan 2019 Energy Efficient Compliant
  • Aluminum Windings for Durability and Performance
  • 3R Enclosure for Moderate Environmental Protection

Specifications

Application
Variable Speed Drives.
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH3-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
36 in
Height
914.4 mm
Insulation Class
220 Deg C Class
KVA Rating
75 KVA
Length
27 in
Length
685.8 mm
Mounting
Floor or Wall mount
Mounting Method
Floor
NEMA Frame Size
Type 3R
Number Of Phases
3
Phase
3PH
Primary Voltage
460D
Secondary Voltage
460Y/266V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
75kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Wall Mounting
No
Warranty
10 year warranty
Weight
580 L
Width
28.3 in
Width
718.82 mm
Winding
Aluminum
Package Dimensions (L x W x H)
27 IN x 28.3 IN x 36 IN
Package Dimensions (L x W x H)
68.58 cm x 71.882 cm x 91.44 cm
Package Weight (Imperial)
580.000 L
Package Weight (Metric)
263.088 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 75kVA 575D-460Y/266V AL 60Hz 3R

TE3A0075NJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 75kVA 575D-460Y/266V AL 60Hz 3R
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1008G33

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V AL 60Hz 3R

TE3A0020KK

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 575D-380Y/220V AL 60Hz 3R

TE3A0027NG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 575D-380Y/220V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V AL 60Hz 3R

TE3A0330KK

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-380Y/220 V AL 60Hz 3R

TE3A0660KG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-380Y/220 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 575D-380Y/220V AL 60Hz 3R

TE3A0550NG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 575D-380Y/220V AL 60Hz 3R

Frequently Asked Questions

What is the insulation system temperature rise for HPS Tribune E transformers?

The HPS Tribune E transformers utilize a uniform 220°C insulation system with standard temperature rise options of 80°C, 115°C, or 150°C.

What is the standard enclosure type for HPS Tribune E transformers?

The standard enclosure type for HPS Tribune E transformers is a heavy-duty ventilated Type 3R, suitable for indoor or outdoor applications.

What is the warranty period for HPS Tribune E transformers?

HPS offers a 10-year warranty on their Tribune E series of transformers.

Are HPS Tribune E transformers NRCan compliant?

Yes, the HPS Tribune E product lines are redesigned to meet the NRCan 2019 compliant energy efficiency standards.

What are the dimensions for the TE3A0075JJ model?

The TE3A0075JJ model has approximate dimensions of 28.30 inches in width, 27.00 inches in depth, and 36.00 inches in height.

What is the weight of the TE3A0075JJ transformer?

The TE3A0075JJ transformer weighs approximately 580 lbs.

What are the standard primary and secondary voltages for the TE3A0075JJ model?

The TE3A0075JJ model is listed with 460 DELTA primary volts and 460Y/266 secondary volts.

What is the typical impedance range for HPS Tribune E transformers?

The typical impedance for HPS Tribune E transformers ranges from 1.8% to 7.5%.

What is the standard BIL rating for HPS Tribune E transformers?

All HPS Tribune E three-phase low voltage products come with a standard 10kV BIL rating for increased reliability.

What mounting options are available for HPS Tribune E transformers?

HPS Tribune E transformers support both floor and wall/ceiling mounting. Integral wall mounting brackets are standard up to 45kVA.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.