Hammond Power TE3A0027NG - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 575D-380Y/220V AL 60Hz 3R

Hammond Power TE3A0027NG 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive…

UPC: 803423143916


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Introducing the Hammond Power TE3A0027NG, a 27 kVA, three-phase drive isolation transformer engineered to meet stringent energy efficiency standards, including DOE2016 and NRCan 2019 compliance. This transformer is designed for 600V class applications, providing reliable isolation for variable frequency drives (VFDs) and other sensitive motor control equipment. With a primary voltage of 575D and a secondary voltage of 380Y/220V, it offers robust power conversion capabilities at a 60 Hz frequency. Constructed with durable aluminum windings, the TE3A0027NG ensures efficient operation and longevity. Its NEMA Type 3R enclosure provides protection against falling rain and sleet, making it suitable for indoor or outdoor installations where moderate environmental protection is required. Featuring screw terminal connections for secure and straightforward wiring, this transformer is ideal for industrial settings demanding dependable power quality and energy savings. The TE3A series from Hammond Power is recognized for its quality and performance in critical drive isolation applications. SKU: TE3A0027NG. UNSPSC Code: 39121029. Country of Origin: US.
  • 27 kVA, Three-Phase Drive Isolation Transformer
  • DOE2016 and NRCan 2019 Energy Efficient Compliant
  • Primary: 575D VAC, Secondary: 380Y/220V, 60 Hz
  • NEMA Type 3R / IP 3R Enclosure for environmental protection
  • Durable Aluminum Windings and Screw Terminal Connections

Specifications

Application
Variable Speed Drives.
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH2-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
28.8 in
Height
731.52 mm
Insulation Class
220 Deg C Class
KVA Rating
27 KVA
Length
23.8 IN
Length
604.52 mm
Mounting
Floor or Wall mount
Mounting Method
Wall and Floor
NEMA Frame Size
Type 3R
Number Of Phases
3
Phase
3PH
Primary Voltage
575D V
Secondary Voltage
380Y/220V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
27kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Wall Mounting
Yes
Warranty
10 year warranty
Weight
280 L
Width
25.8 in
Width
655.32 mm
Winding
Aluminum
Package Dimensions (L x W x H)
23.8 IN x 25.8 IN x 28.8 IN
Package Dimensions (L x W x H)
60.452 cm x 65.532 cm x 73.152 cm
Package Weight (Imperial)
280.000 L
Package Weight (Metric)
127.008 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V AL 60Hz 3R

TE3A0027JC

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V AL 60Hz 3R
Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H118S

Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1008G33

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V AL 60Hz 3R

TE3A0330KK

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-380Y/220 V AL 60Hz 3R

TE3A0660KG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-380Y/220 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 575D-380Y/220V AL 60Hz 3R

TE3A0550NG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 575D-380Y/220V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 480D-380Y/220 V AL 60Hz 3R

TE3A0034KG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 480D-380Y/220 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 63kVA 575D-460Y/266V AL 60Hz 3R

TE3A0063NJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 63kVA 575D-460Y/266V AL 60Hz 3R

Frequently Asked Questions

What is the insulation system and temperature rise for this transformer?

The transformer features a 220°C insulation system with a standard 150°C temperature rise. Optional 115°C and 80°C rises are also available.

What is the standard enclosure type for HPS Tribune E transformers?

The standard enclosure type is a heavy-duty ventilated Type 3R, suitable for indoor or outdoor applications.

What are the available winding materials?

The transformers are available with either copper or aluminum conductors.

What certifications does the HPS Tribune E transformer have?

The transformer is UL Listed (File: E112313) and CSA Certified (File: LR3902).

What is the warranty period for HPS transformers?

HPS transformers come with a 10-year warranty.

What are the dimensions for a 27 kVA TE3A0027NG transformer?

The approximate dimensions for a 27 kVA TE3A0027NG transformer are: Width 25.80 in, Depth 23.80 in, and Height 28.80 in.

What is the weight of a 27 kVA TE3A0027NG transformer?

The approximate weight for a 27 kVA TE3A0027NG transformer is 280 Lbs [126 kg].

Are there optional accessories available for these transformers?

Yes, optional accessories include thermal indication, thermometers, strip heaters, surge protection devices, and different enclosure types.

What are the mounting options for the HPS Tribune E transformers?

The transformers can be floor or wall mounted. Built-in wall ceiling mounting is standard on some models, with kits available for others.

What is the frequency rating for this transformer?

The standard frequency rating is 60 Hz, with an optional 50/60 Hz available.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.