Hammond Power TE3A0020NN - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 575D-575Y/332V AL 60Hz 3R
Hammond Power

TE3A0020NN

UPC: 803423144241


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Overview

The Hammond Power TE3A0020NN is a 20kVA, three-phase, drive isolation transformer designed for energy efficiency and compliance with DOE2016 and NRCan 2019 standards. This transformer operates with a primary voltage of 575D and a secondary voltage of 575Y/332V, at a frequency of 60Hz. Constructed with aluminum windings, it ensures reliable performance in demanding industrial applications. Its robust design and compliance with energy efficiency regulations make it an ideal choice for motor control applications where clean power and reduced energy consumption are critical. The 3R enclosure provides protection suitable for various industrial environments. This transformer is manufactured in the USA, ensuring quality and adherence to strict manufacturing protocols. Its specific ratings and compliance certifications highlight its suitability for modern industrial power systems, offering a dependable solution for isolating variable frequency drives (VFDs) and other sensitive equipment from line notching and voltage transients. The TE3A0020NN is engineered to provide a stable and clean power source, protecting connected equipment and optimizing operational efficiency. Its 600V class rating signifies its capability to handle significant voltage levels safely and effectively within industrial settings.
  • 20kVA, Three-Phase Drive Isolation Transformer
  • 600V Class, 575D Primary / 575Y/332V Secondary
  • DOE2016 and NRCan 2019 Energy Efficient Compliant
  • Aluminum Windings for Enhanced Efficiency
  • 60Hz Frequency, 3R Enclosure, Made in USA

Specifications

Application
Variable Speed Drives.
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH1-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
22 in
Insulation Class
220 Deg C Class
KVA Rating
20 KVA
Length
20.1 in
Mounting
Floor or Wall mount
Mounting Method
Wall and Floor
NEMA Frame Size
Type 3R
Number Of Phases
3
Phase
3PH
Primary Voltage
575D V
Secondary Voltage
575Y/332V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
20kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Wall Mounting
Yes
Warranty
10 year warranty
Weight
220 L
Width
21.5 in
Winding
Aluminum
Package Dimensions (L x W x H)
20.1 IN x 21.5 IN x 22 IN
Package Dimensions (L x W x H)
51.054 cm x 54.61 cm x 55.88 cm
Package Weight (Imperial)
220.000 L
Package Weight (Metric)
99.792 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V AL 60Hz 3R

TE3A0020KK

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V AL 60Hz 3R
Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651F7.5S

Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1004G63

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

Frequently Asked Questions

What are the key features of this transformer?

The transformer features a standard Type 3R enclosure suitable for indoor or outdoor applications, uses a 220°C insulation system, has a 10kV BIL rating, and includes integral floor and wall mounting brackets up to 45kVA.

What is the standard frequency and voltage range?

The transformer is designed for 60 Hz frequency, with optional 50/60 Hz availability. Voltage ranges vary by model, with multiple primary and secondary voltage configurations available.

What conductor materials are used?

The transformer can be wound with either copper or aluminum conductors, which are precision wound and electrically balanced to minimize axial forces during short-circuit conditions.

What is the warranty period?

The transformer comes with a 10-year warranty.

What mounting options are available?

The transformer supports floor or wall/ceiling mounting. For sizes up to 45kVA, wall mounting brackets are standard, and floor mounting is also available.

What temperature rise options are available?

The transformer offers temperature rise options of 80°C, 115°C, and 150°C, with 150°C being the standard configuration for drive isolation transformers.

What safety and protection features are included?

The transformer includes a standard 10kV BIL rating, electrostatic shielding, and a thermostat (200°C N.C. thermostats on each coil) for enhanced protection and reliability.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.