Hammond Power TE3A0093KG - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 93kVA 480D-380Y/220 V AL 60Hz 3R

Hammond Power TE3A0093KG 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive…

UPC: 803423143633


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power TE3A0093KG is a 600V class three-phase drive isolation transformer designed for energy efficiency and regulatory compliance. Rated at 93kVA, this transformer operates at 480D-380Y/220V with an aluminum winding and 60Hz frequency. It meets DOE2016 and NRCan 2019 energy efficiency standards, ensuring reduced power losses and lower operational costs in industrial applications. The 3R enclosure rating provides protection against environmental conditions, making it suitable for indoor or outdoor installations where dust, rain, or snow exposure is possible. With a compact design and high reliability, this transformer is ideal for use in motor drives, power conversion systems, and other industrial equipment requiring stable voltage regulation and isolation. The aluminum winding construction offers lightweight durability and efficient heat dissipation, while the 3-phase design ensures balanced power distribution. Compliance with DOE2016 and NRCan 2019 guarantees energy savings and reduced carbon footprint, aligning with modern sustainability goals. The TE3A0093KG is manufactured in the US, ensuring high-quality craftsmanship and adherence to strict industry standards.
  • 93kVA three-phase drive isolation transformer
  • DOE2016 and NRCan 2019 energy efficiency compliant
  • 480D-380Y/220V input/output voltage configuration
  • Aluminum winding for lightweight durability and heat dissipation
  • 3R enclosure rating for indoor/outdoor environmental protection

Specifications

Application
Variable Speed Drives.
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH3-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
36 in
Height
914.4 mm
Insulation Class
220 Deg C Class
Ip Rating
3R
KVA Rating
93 KVA
Length
27 in
Length
685.8 mm
Material
Aluminum
Mounting
Floor or Wall mount
Mounting Method
Floor
NEMA Frame Size
Type 3R
NEMA Rating
Type 3R
Number Of Phases
3
Phase
3PH
Primary Voltage
480D V
Secondary Voltage
380Y/220 V
Secondary Voltage
380Y/220 VAC
Series
TE3A
Size
93 kVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
93kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Voltage Rating
480D-380Y/220 VAC
Wall Mounting
No
Warranty
10 year warranty
Weight
615 L
Width
28.3 in
Width
718.82 mm
Winding
Aluminum
Package Dimensions (L x W x H)
27 IN x 28.3 IN x 36 IN
Package Dimensions (L x W x H)
68.58 cm x 71.882 cm x 91.44 cm
Package Weight (Imperial)
615.000 L
Package Weight (Metric)
278.964 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 93kVA 460D-460Y/266V AL 60Hz 3R

TE3A0093JJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 93kVA 460D-460Y/266V AL 60Hz 3R
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1008G33

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 220kVA 575D-460Y/266V AL 60Hz 3R

TE3A0220NJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 220kVA 575D-460Y/266V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 575D-575Y/332V AL 60Hz 3R

TE3A0034NN

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 575D-575Y/332V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 63kVA 480D-380Y/220 V AL 60Hz 3R

TE3A0063KG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 63kVA 480D-380Y/220 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 175kVA 460D-460Y/266V AL 60Hz 3R

TE3A0175JJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 175kVA 460D-460Y/266V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 93kVA 480D-480Y/277 V AL 60Hz 3R

TE3A0093KK

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 93kVA 480D-480Y/277 V AL 60Hz 3R

Frequently Asked Questions

What is the insulation system and temperature rise for this transformer?

The transformer features a uniform 220°C insulation system with options for 80°C, 115°C, or 150°C temperature rise.

What are the standard enclosure types and finishes?

It comes with a standard heavy-duty ventilated Type 3R enclosure with an ANSI 61 Grey finish. Optional Type 4, 4X (stainless steel), and 12 enclosures are available.

What is the BIL rating for these transformers?

The standard BIL rating is 10kV, providing increased reliability against voltage spikes and line transients.

What mounting options are available for the transformer?

The transformer supports both floor and wall/ceiling mounting. Integral floor and wall mounting brackets are standard up to 45kVA.

What is the typical impedance range for this transformer series?

The typical impedance for these transformers ranges from 1.8% to 7.5%.

What is the frequency rating of the HPS Tribune E transformers?

The standard frequency rating is 60 Hz, with an optional 50/60 Hz available.

What are the K-Rating considerations for this transformer?

The kVA sizing allows for motor efficiency and 6 Pulse Drive Harmonics, with a K-Rating of K=13.

What safety certifications does this product have?

The HPS Tribune E transformers are UL Listed (File: E112313) and CSA Certified (File: LR3902).

What are the benefits of the high efficiency design?

Higher efficiency translates to increased profitability through lower operating costs, decreased cost of ownership, and reduced air conditioning costs due to lower heat emissions.

What are the standard dimensions for the 93 kVA model?

The 93 kVA model (TE3A0093KG) has approximate dimensions of 28.30 inches in width, 27.00 inches in depth, and 36.00 inches in height.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.