Authorized Hammond Power Distributor
Hammond Power SK3A0300PK4S - 600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 4, 600D PV, 480Y/277 SV, 300 kVA, Three Phase, Aluminum Wound, Shielded
Hammond Power

SK3A0300PK4S

UPC: 803423129187


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power SK3A0300PK4S is a 300 kVA, three-phase, K-Factor 4 transformer designed for energy efficiency and compliance with DOE 2016 and NRCan 2019 standards. This unit features aluminum windings and a shielded design, making it an ideal solution for applications experiencing harmonic distortion from non-linear loads. Operating at 600V Class, it is configured for 480Y/277V service, providing reliable power distribution. The K-Factor rating of 4 is specifically engineered to handle the increased heating effects caused by harmonic currents generated by equipment such as variable frequency drives (VFDs), LED lighting, and other modern electronic loads. By mitigating these harmonics, the transformer reduces core and winding temperatures, extends insulation life, and prevents premature failure. Its shielded construction further enhances performance by minimizing electromagnetic interference (EMI) and radio frequency interference (RFI), ensuring cleaner power output and protecting sensitive downstream equipment. Manufactured in the US, this transformer offers a robust and compliant solution for industrial facilities, data centers, and commercial buildings requiring stable and efficient power under challenging load conditions. SKU: SK3A0300PK4S.
  • Specifically designed to handle the harmonics generated by non-linear loads such as computer and telecommunication equipment, drives and other power electronics
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12;  Mexico - NMX-J-351-ANCE-2021
  • Standard three phase voltage groups available at k-factor ratings of K4, K9, K13
  • Shielded Design for Harmonic Distortion
  • 600V Class, 480Y/277V Service

Specifications

Application
Addresses the overheating problems due to harmonics associated with non-linear loads where drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations.
Cable Entry
Side knock-outs standard on all units
Cooling
Convection cooled
Depth
34 IN
Enclosure
DH5-N3R - Indoor or Outdoor
Enclosure Color
ANSI 61 Grey
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
52 in
KVA Rating
300 KVA
Length
34 in
Mounting
Floor Mount
Mounting Method
Floor
Number Of Phases
3
Number Of Taps
ST-20 compliant
Phase
3PH
Phase
A - 3PH Delta-Wye-N
Primary Voltage
600D V
Secondary Voltage
480Y/277V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150
Transformer Rating
300kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > K Factor > Three Phase
Wall Mounting
No
Warranty
10 year warranty
Weight
1830 lbs
Width
37.5 in
Winding
AL
Winding
S - AL + Shield
Package Dimensions (L x W x H)
34 IN x 37.5 IN x 52 IN
Package Dimensions (L x W x H)
86.36 cm x 95.25 cm x 132.08 cm
Package Weight (Imperial)
1830.000 L
Package Weight (Metric)
830.088 kg
600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 4, 600D PV, 208Y/120 SV, 300 kVA, Three Phase, Aluminum Wound, Shielded

SK3A0300PB4S

600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 4, 600D PV, 208Y/120 SV, 300 kVA, Three Phase, Aluminum Wound, Shielded
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 150 KVA, Primary Voltage 480 V, Secondary Voltage 240 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 80 Degrees C, Connection Delta-Delta W/ Ct, Winding Aluminium, Enclosure Nema Type 1

E5HB150S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 150 KVA, Primary Voltage 480 V, Secondary Voltage 240 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 80 Degrees C, Connection Delta-Delta W/ Ct, Winding Aluminium, Enclosure Nema Type 1
ABB's Servicenter™ Three-Phase Integral Transformer and Distribution Panel system meets DOE 2016 efficiency standards. The Servicenter system comes equipped with the rightly sized circuit breakers for both the primary and secondary transformer windings. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022. Available with aluminum or copper windings. The transformer utilizes a UL recognized 220 °C insulation system. Quiet Performance as core and coil assemblies are mounted on rubber isolation pads to reduce noise. Robust packaging with top and side protection protects against shipping damage. Accessible mounting flanges with front/back slotted mounting holes make installation easier. NEMA 3R enclosure when the included rain shields are installed. Clear, comprehensive documentation and labeling. The Servicenter system is UL Listed.

9T17C0014

ABB's Servicenter™ Three-Phase Integral Transformer and Distribution Panel system meets DOE 2016 efficiency standards. The Servicenter system comes equipped with the rightly sized circuit breakers for both the primary and secondary transformer windings. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022. Available with aluminum or copper windings. The transformer utilizes a UL recognized 220 °C insulation system. Quiet Performance as core and coil assemblies are mounted on rubber isolation pads to reduce noise. Robust packaging with top and side protection protects against shipping damage. Accessible mounting flanges with front/back slotted mounting holes make installation easier. NEMA 3R enclosure when the included rain shields are installed. Clear, comprehensive documentation and labeling. The Servicenter system is UL Listed.
Zeebar Aluminum Transformer Connector, #6 - 500 kcmil, Aluminum and Copper, Stud 5/8 inch and 1 inch. Option R - Right Hand Feed, Option V4, 6.93 inches long, 2.31 inches wide, 2.84 inches high, 8 Conductor

Z 6830 R V4

Zeebar Aluminum Transformer Connector, #6 - 500 kcmil, Aluminum and Copper, Stud 5/8 inch and 1 inch. Option R - Right Hand Feed, Option V4, 6.93 inches long, 2.31 inches wide, 2.84 inches high, 8 Conductor
15 kVA Single-Phase Ventilated Transformer

421-9160-000

15 kVA Single-Phase Ventilated Transformer
REXPOWER 15KVA 3PH 60HZ NEMA 1

BA15C-P/Z3

REXPOWER 15KVA 3PH 60HZ NEMA 1
1.2kV to 5kV Class General Purpose Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Dry-type Medium Voltage Distribution Transformer, 4160D PV, 208Y/120 SV, 750 kVA, Copper Wound

MG3A0750SBSCHC0

1.2kV to 5kV Class General Purpose Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Dry-type Medium Voltage Distribution Transformer, 4160D PV, 208Y/120 SV, 750 kVA, Copper Wound
600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 480D PV, 240/120 SV, 15 kVA, 3PH, Aluminum Wound

SG3C0015KD

600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 480D PV, 240/120 SV, 15 kVA, 3PH, Aluminum Wound

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.