Hammond Power MG3A0750SBSCHC0 1.2kV to 5kV Class General Purpose Single Phase DOE2016 and NRCan 2019 Compliant Energy…
UPC: 803423134440
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 750 kVA, Single Phase, Dry-type Medium Voltage Distribution Transformer
- DOE2016 and NRCan 2019 Energy Efficient Compliant
- Copper Wound Construction for Optimal Conductivity
- Primary: 4160D PV, Secondary: 208Y/120 SV
- 1.2kV to 5kV Class Operation, 60 Hz Frequency
Specifications
Application | Industrial and Commercial Applications including Mining, Water Waste Water, Utility and Data Centers |
Connection Type | Dry-type Medium Voltage |
Connection Type | Not explicitly stated |
Connection Type | Delta (Primary) / Wye (Secondary) |
Connection Type | D / Y |
Connection Type | Dry-type |
Connection Type | 4160D PV / 208Y/120 SV |
Connection Type | Delta (4160D) / Wye (208Y/120V) |
Cooling | Convection cooled |
Current Rating | 750 kVA |
Enclosure | DH8-N3R - Indoor or Outdoor |
Frequency | 60 Hz |
Frequency Rating | 60 HZ |
Height | 82 in |
KVA Rating | 750 KVA |
Length | 49.5 in |
Material | Copper |
Material | Copper Wound |
Mounting | Floor Mount |
Mounting Type | Dry-type Medium Voltage Distribution |
Number Of Phases | 3 |
Number Of Taps | ST-20 compliant |
Phase | A - 3PH - Delta - Wye |
Poles | Single Phase |
Poles | 1 |
Primary Voltage | 4160D V |
Secondary Voltage | 208Y/120 V |
Series | MG3A |
Size | 750 kVA |
Special Features | Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs. |
Standard | CSA, UL |
Temperature Rating | Typical 30 Average/ 40 Maximum Deg C |
Type | Transformer > Distribution > DOE 2016 Energy Efficient > Medium Voltage > Three Phase |
Voltage Rating | 4160D PV / 208Y/120V |
Voltage Rating | 4160 VAC |
Voltage Rating | 4160D PV (Primary) / 208Y/120V (Secondary) |
Voltage Rating | 4160D PV primary / 208Y/120V secondary |
Width | 60 in |
Winding | Copper |
Package Dimensions (L x W x H) | 49.5 IN x 60 IN x 82 IN |
Package Dimensions (L x W x H) | 125.73 cm x 152.4 cm x 208.28 cm |
Package Weight (Imperial) | 5500.000 L |
Package Weight (Metric) | 2494.800 kg |
Frequently Asked Questions
What are the primary and secondary voltage options for this transformer?
Primary voltages range up to 5kV Class with 45kV BIL. Secondary voltages for three-phase units are 208Y/120V to 600Y/347V with 10kV BIL.
What is the typical impedance for this transformer series?
Single-phase units typically have an impedance of 2-5%, while three-phase units typically have an impedance of 3-6%.
What is the standard temperature rise for the windings?
The standard temperature rise is 150°C, with 130°C rise for some lower kVA units. Optional 115°C and 80°C rises are available.
What insulation system temperature class is used?
The insulation system is rated for 220°C, with 200°C used for some units.
What standards does this transformer comply with?
It complies with DOE 10 CFR Part 431: 2016 and NRCAN 2019 SOR/2018-201 Amd. 14, among other industry standards like IEEE and UL.
What winding materials are available for this transformer?
The transformer can be wound with either copper or aluminum conductors.
What are the dimensions for a 750 kVA, 4160V primary, 600Y/347V secondary unit?
For a 750 kVA unit with these specifications, the dimensions are 60.0 inches in width, 50.0 inches in depth, and 82.0 inches in height.
What is the weight of a 750 kVA, 4160V primary, 600Y/347V secondary copper wound unit?
A 750 kVA, 4160V primary, 600Y/347V secondary copper wound unit weighs 5500 lbs.
What are the available enclosure types for this transformer?
Type 3/3R is standard, with an enhanced Type 3R option for improved outdoor performance. Other enclosure options are available upon request.
What are the mounting options for this transformer?
Floor or wall/ceiling mounting is available. Specific mounting types depend on the kVA rating and enclosure.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.