Authorized Hammond Power Distributor
Hammond Power SG3L0025BE0C - 600V Class Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 208 PV, 120/240 SV, 25 kVA, 1PH, Copper Wound
More images

Hammond Power SG3L0025BE0C 600V Class Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution…

UPC: 803423140564


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This transformer delivers a 600V primary voltage (208 PV) and a 120/240V secondary voltage (120/240 SV), making it ideal for general-purpose distribution in industrial and commercial applications. Constructed with copper windings, it ensures reliable performance and efficient power transfer, reducing energy consumption and operational costs. Designed for single-phase systems rated 15 kVA and larger, this ventilated transformer features convection air cooling and a single 3-leg core. It meets or exceeds NEMA standards for primary side taps and is built to UL, CSA, and NEMA specifications. For non-linear load applications, the transformer is de-rated per ANSI/IEEE C57.110 to maintain optimal performance and longevity. Primary voltage options include 208V, 240V, 277V, 416V, 480V, and 600V, while secondary voltage is fixed at 120/240V. The system frequency is 60 Hz, ensuring compatibility with standard power grids. This transformer is suitable for supplying power to loads such as appliances, lighting, heating systems, and motorized machinery within electrical distribution systems.
  • HPS general purpose distribution transformers are rated for 600 volts and below.
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12; Mexico - NMX-J-351-1-ANCE-2021
  • HPS also offers a line of low voltage Smart Transformers with integrated power monitoring for enhanced energy management and real-time performance insights.
  • Ventilated, convection air-cooled design with single 3-leg core
  • Meets or exceeds NEMA standards for primary side taps
  • UL, CSA, and NEMA rated for reliability and safety
  • De-rated per ANSI/IEEE C57.110 for non-linear load applications
  • Primary voltage options: 208V, 240V, 277V, 416V, 480V, 600V
  • System frequency: 60 Hz

Specifications

Application
General purpose for supplying appliance, lighting, motorized machine and power loads from electrical distribution systems.
Cable Entry
Knock Outs
Connection Type
120/240 SV
Cooling
Convection cooled
Enclosure
NH6-N3R - Indoor or Outdoor
Enclosure Color
ANSI 61 Grey, UL 50
Enclosure Type
Type 3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
26.7 in
Height
678.18 mm
Impedance
Typically 1.8% to 7.5%
Insulation Class
220°C
KVA Rating
25 KVA
Length
23.8 in
Length
604.52 mm
Material
Copper
Material
Copper Wound
Mounting
Floor or Wall mount
Mounting Method
Wall/Floor
Number Of Taps
ST-20 compliant
Phase
1PH
Phase
L- 1PH Single-Dual
Poles
1PH
Primary Voltage
208 V
Secondary Voltage
120/240V
Series
SG3L
Size
25 KVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150°C
Termination
Mechanical Lugs
Transformer Rating
25kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > General Purpose > Single Phase
Voltage Rating
208 VAC / 120/240 VAC
Voltage Rating
600 V
Wall Mounting
Yes
Warranty
10 year warranty
Width
22.3 in
Width
566.42 mm
Winding
Copper
Winding
C - Copper
Package Dimensions (L x W x H)
23.8 IN x 22.3 IN x 26.7 IN
Package Dimensions (L x W x H)
60.452 cm x 56.642 cm x 67.818 cm
Package Weight (Imperial)
230.000 L
Package Weight (Metric)
104.328 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

What is the insulation system temperature rise for this transformer?

The standard insulation system is 220ºC, with optional 115ºC and 80ºC temperature rises available.

What is the BIL rating for HPS Sentinel G transformers?

The standard BIL rating for HPS Sentinel G transformers is 10 kV.

What type of enclosure is standard on HPS transformers?

All low voltage HPS transformers come with a standard Type 3R enclosure.

What are the mounting options for this transformer?

This transformer can be mounted on the floor or on a wall/ceiling.

What is the warranty period for HPS Sentinel transformers?

HPS Sentinel transformers come with a 10-year warranty.

Are these transformers compliant with US and Canadian energy regulations?

Yes, the HPS Sentinel G, K, and H product lines meet DOE 2016 and NRCan 2019 energy efficiency standards.

What conductor materials are used in these transformers?

The conductors used in these transformers can be either copper or aluminum.

What is the standard frequency for these transformers?

The standard frequency for these transformers is 60 Hz, with optional 50/60 Hz available.

What are the dimensions for the 25 kVA SG3L0025BE0C model?

The 25 kVA SG3L0025BE0C model has approximate dimensions of 22.30 inches in width, 23.80 inches in depth, and 26.70 inches in height.

What is the weight of the 25 kVA SG3L0025BE0C model?

The 25 kVA SG3L0025BE0C model weighs approximately 230 Lbs.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.