The Hammond Power SG3A0045KB0CFC3 is a 600V-class three-phase distribution transformer engineered for compliance with DOE2016 and NRCan 2019 energy efficiency standards. Rated at 45 kVA, this transformer features a primary voltage of 480V delta and a secondary voltage of 208Y/120V, making it ideal for industrial, commercial, and institutional applications requiring stepped-down three-phase power. Constructed with copper windings, it ensures low losses, high reliability, and long service life. This transformer delivers 98.4% efficiency at 35% load, significantly reducing energy consumption and operational costs compared to standard models. Its compact design includes a heavy-duty ventilated Type 3R enclosure with ANSI 61 grey finish, pre-installed lugs, and floor mounting feet as standard. Optional wall/ceiling mounting kits (DW3) are available for flexible installation. The transformer meets UL 1562, CSA C22.2 No. 47, and seismic qualification standards (IBC 2018/ASCE 7-16), ensuring compliance with North American safety and performance requirements. Designed for general-purpose distribution, the SG3A0045KB0CFC3 supplies appliance, lighting, heating, and motorized machine loads from electrical distribution systems. Side conduit knock-outs and separate high/low voltage terminal boards simplify wiring, while vibration isolation pads enhance reliability in demanding environments. Certified for use in the US and Canada, this transformer is a cost-effective solution for facilities prioritizing energy savings, regulatory compliance, and long-term reliability.
  • HPS general purpose distribution transformers are rated for 600 volts and below.
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12; Mexico - NMX-J-351-1-ANCE-2021
  • HPS also offers a line of low voltage Smart Transformers with integrated power monitoring for enhanced energy management and real-time performance insights.
  • Copper windings for low losses and high reliability
  • Heavy-duty Type 3R enclosure with ANSI 61 grey finish
  • Pre-installed lugs, floor mounting feet, and optional wall/ceiling mounting
  • UL 1562 and CSA C22.2 No. 47 certified
  • Seismic qualified (IBC 2018/ASCE 7-16)
  • Side conduit knock-outs and separate terminal boards for easy wiring
  • Vibration isolation pads for enhanced durability

Specifications

Application
General purpose for supplying appliance, lighting, motorized machine and power loads from electrical distribution systems.
Cable Entry
Knock Outs
Cooling
Convection cooled
Enclosure
Contact HPS
Enclosure Color
ANSI 61 Grey, UL 50
Enclosure Type
Type 3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
36 in
Height
914.4 mm
Height
Contact HPS in
Impedance
Typically 1.8% to 7.5%
Insulation Class
220°C
KVA Rating
45 KVA
Length
Contact HPS in
Length
27 in
Length
685.8 mm
Mounting
Floor or Wall/Ceiling Mount
Mounting Method
Wall/Floor
Number Of Phases
3
Number Of Taps
ST-20 compliant
Phase
3PH
Phase
3PH Delta-Wye-N
Primary Voltage
480D V
Primary Voltage
480 VAC
Secondary Voltage
208Y/120V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150°C
Termination
Mechanical Lugs
Transformer Rating
45kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > General Purpose > Three Phase
Wall Mounting
Yes
Warranty
10 year warranty
Width
Contact HPS
Width
28.25 in
Width
717.55 mm
Winding
Copper
Package Dimensions (L x W x H)
23.8 IN x 25.75 IN x 28.75 IN
Package Dimensions (L x W x H)
605 mm x 655 mm x 731 mm
Package Weight (Imperial)
450.000 L
Package Weight (Metric)
205.000 kg
600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Harmonic Mitigating Transformer, 600YD PV, 208Y/120 SV, 112.5 kVA, 3PH, Copper Wound, Shielded, -30 Deg Phase Shift

SH3U0112PB3K

600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Harmonic Mitigating Transformer, 600YD PV, 208Y/120 SV, 112.5 kVA, 3PH, Copper Wound, Shielded, -30 Deg Phase Shift
Features:Wall Mounting Bracket (WB1C), Primary Amperage 62.5/31.3A, Secondary Amperage 125/62.5A, 220 DEG C Insulation System, Standard:UL, KVA Rating:15KVA, Primary Voltage:240/480V AC, Secondary Voltage:120/240V AC

ES5H15S

Features:Wall Mounting Bracket (WB1C), Primary Amperage 62.5/31.3A, Secondary Amperage 125/62.5A, 220 DEG C Insulation System, Standard:UL, KVA Rating:15KVA, Primary Voltage:240/480V AC, Secondary Voltage:120/240V AC
This ABB General purpose transformer includes an electrostatic shield.

9T10A1172G03

This ABB General purpose transformer includes an electrostatic shield.
REXPOWER 15KVA 3PH 60HZ NEMA 1

BA15C-P/Z3

REXPOWER 15KVA 3PH 60HZ NEMA 1
Tin-Plated Copper Overhead Transformer Eyebolt Adapter, pin diameter 1/2, exposed pin size 2-5/8 inch

CEA 2-50

Tin-Plated Copper Overhead Transformer Eyebolt Adapter, pin diameter 1/2, exposed pin size 2-5/8 inch
15 kVA Single-Phase Ventilated Transformer

421-9160-000

15 kVA Single-Phase Ventilated Transformer

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.