Authorized Hammond Power Distributor
Hammond Power MG3A0500SPSCHC0 - 1.2kV to 5kV Class General Purpose Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Dry-type Medium Voltage Distribution Transformer, 4160D PV, 600Y/347 SV, 500 kVA, Copper Wound

Hammond Power MG3A0500SPSCHC0 1.2kV to 5kV Class General Purpose Single Phase DOE2016 and NRCan 2019 Compliant Energy…

UPC: 803423135744


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This unit operates within the 1.2kV to 5kV class, featuring a 4160D PV primary and a 600Y/347 SV secondary. Its copper windings deliver lower energy losses and superior thermal performance, reducing operational costs while enhancing reliability. The transformer meets DOE2016 and NRCan 2019 energy efficiency standards, ensuring environmental responsibility and cost-effectiveness for industrial and commercial applications. Designed for space-constrained indoor environments, the MG3A0500SPSCHC0 features a compact DOE2016 footprint optimized for installation in manufacturing plants, data centers, and institutional facilities. The robust copper construction provides exceptional electrical conductivity and heat dissipation, critical for sustained performance under load. Key applications include: - Manufacturing facilities requiring efficient medium voltage distribution - Data centers with high power density demands - Institutional buildings such as hospitals and universities - Industrial plants with space-constrained electrical rooms
  • 500 kVA single-phase dry-type medium voltage transformer
  • DOE2016 and NRCan 2019 energy efficiency compliant
  • 4160D PV primary / 600Y/347 SV secondary voltage ratings
  • Copper windings for lower energy losses and superior thermal performance
  • Compact DOE2016 footprint optimized for space-constrained indoor installations

Specifications

Application
Industrial and Commercial Applications including Mining, Water Waste Water, Utility and Data Centers
Connection Type
Dry-type Medium Voltage Distribution
Cooling
Convection cooled
Enclosure
DH6-N3R - Indoor or Outdoor
Frequency
60 Hz
Frequency Rating
60 HZ
Height
64 IN
KVA Rating
500 KVA
Length
41.5 IN
Material
Copper Wound
Material
Copper
Mounting
Floor Mount
Mounting Type
Indoor
Number Of Phases
3
Number Of Taps
ST-20 compliant
Phase
A - 3PH - Delta - Wye
Poles
Single Phase
Primary Voltage
4160D V
Secondary Voltage
600Y/347 V
Series
MG3A
Size
500 kVA
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Type
Transformer > Distribution > DOE 2016 Energy Efficient > Medium Voltage > Three Phase
Voltage Rating
4160V
Voltage Rating
1.2kV to 5kV (Primary: 4160V, Secondary: 600Y/347V)
Voltage Rating
1.2kV to 5kV
Voltage Rating
4160D PV / 600Y/347 SV
Width
49 IN
Winding
Copper
Package Dimensions (L x W x H)
41.5 IN x 49 IN x 64 IN
Package Dimensions (L x W x H)
105.41 cm x 124.46 cm x 162.56 cm
Package Weight (Imperial)
3100.000 L
Package Weight (Metric)
1406.160 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

Are these transformers compliant with DOE and NRCan efficiency guidelines?

Yes, HPS Millennium G transformers are designed to meet DOE 2016/NRCan 2019 efficiency standards.

What is the insulation temperature class for HPS Millennium G transformers?

The insulation temperature class is typically 220°C, with some units at 200°C.

What are the standard enclosure types for HPS Millennium G transformers?

The standard enclosure type is Type 3/3R, with an enhanced Type 3R option for improved outdoor performance.

What is the typical temperature rise for these transformers?

The typical temperature rise is 150°C, with lower kVA units having a 130°C rise. Optional 115°C and 80°C rises are available.

What are the primary voltage options for three-phase aluminum wound transformers?

Primary voltage options include 2400 Delta and 4160 Delta.

What secondary voltage options are available for three-phase aluminum wound transformers?

Available secondary voltages are 208Y/120V, 480Y/277V, and 600Y/347V.

What is the frequency rating for these transformers?

The standard frequency rating is 60 Hz, with other frequencies available upon request.

What are the mounting options for HPS Millennium G transformers?

Mounting options include floor mounting and wall/ceiling mounting.

What is the ambient temperature range for operation?

The operating ambient temperature range is -20 to 40°C, with de-rating required from 40°C to 60°C.

What seismic qualifications do these transformers meet?

They are seismically qualified according to IBC 2018 and ASCE 7-16 specifications.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.