Authorized Hammond Power Distributor
Hammond Power CRX74D4PE - Reactor, 74.4 Amperes, 0.49 Millihenries Inductance, 50 Hertz, Enclosed.
More images

Hammond Power CRX74D4PE Reactor, 74.4 Amperes, 0.49 Millihenries Inductance, 50 Hertz, Enclosed.

UPC: 803423150457


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX74D4PE enclosed reactor is a high-current inductive component designed for industrial power distribution and motor control applications. Rated for 74.4 Amperes continuous current and 0.49 millihenries inductance at 50 Hertz, this reactor provides essential harmonic mitigation and current limiting in variable frequency drive (VFD) systems, switchgear, and motor control centers. The enclosed design delivers protection against dust, contaminants, and mechanical damage while maintaining efficient thermal performance in harsh environments. With a compact footprint optimized for space-constrained installations, the CRX74D4PE reduces system complexity without sacrificing electrical performance. Copper terminal pads or terminal blocks provide secure terminations, and contractors must supply necessary lugs.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Compact footprint optimized for space-constrained installations
  • Copper terminal pads or terminal blocks for secure terminations

Specifications

Current Rating
74.4 A
Frequency
50 Hz
Series
CRX
Package Dimensions (L x W x H)
14 IN x 14 IN x 12.13 IN
Package Dimensions (L x W x H)
355 mm x 355 mm x 308 mm
Package Weight (Imperial)
34.000 L
Package Weight (Metric)
16.000 kg
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP
REACTOR LRW200D3N1

LRW200D3N1

REACTOR LRW200D3N1
Reactor, Three Phase, 600 Horsepower, 5% Impedance, 750 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0750DE

Reactor, Three Phase, 600 Horsepower, 5% Impedance, 750 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactor, Three Phase, 1000 Horsepower, 3% Impedance, 1000 Amperes, Copper Windings, 60 Hertz.

CRX1000CC

Reactor, Three Phase, 1000 Horsepower, 3% Impedance, 1000 Amperes, Copper Windings, 60 Hertz.
Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0700CE

Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactor, Three Phase, 1000 Horsepower, 5% Impedance, 1200 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX1200DE

Reactor, Three Phase, 1000 Horsepower, 5% Impedance, 1200 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactor, Three Phase, 700 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0900DE

Reactor, Three Phase, 700 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

Supported system voltages include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The available impedance ratings are 1.5%, 3%, and 5%.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending component life, reducing motor noise and temperature, and minimizing harmonic distortion.

What standards are HPS Centurion R reactors compliant with?

They are compliant with UL, CSA, CE, IEC, and NEMA standards.

What is the inductance tolerance for HPS Centurion R reactors?

The inductance tolerance is +15/-10%.

How are the reactors cooled?

The reactors are cooled using natural convection.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What type of enclosure is standard for HPS Centurion R reactors?

The standard enclosure type is Type 1, with Type 3R available upon consultation.

What is the warranty period for HPS Centurion R reactors?

The reactors come with a 10-year limited warranty.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.