Authorized Hammond Power Distributor
Hammond Power CRX0700CE - Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60 Hertz, Enclosed.
More images

Hammond Power CRX0700CE Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60…

UPC: 803423139308


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0700CE is a three-phase, enclosed reactor designed for industrial applications requiring precise current control and harmonic mitigation. This unit features a substantial 700 horsepower rating and a 700 Ampere current capacity, making it suitable for high-demand electrical systems. With a 3% impedance, it effectively limits fault currents and reduces harmonic distortion, contributing to a more stable and reliable power supply. The reactor is constructed with durable copper windings for efficient energy transfer and longevity. Operating at a standard 60 Hertz frequency, the CRX0700CE is built to integrate seamlessly into existing industrial power infrastructure. Its enclosed design provides protection against environmental factors, enhancing operational safety and extending the product's service life. The HPS Centurion™ R series, to which this reactor belongs, is recognized for its improved performance and reliability, often with a reduced physical footprint compared to previous models, offering a practical solution for space-constrained installations. Manufactured in the USA, this reactor adheres to high production standards. Its UNSPSC code is 39121015, categorizing it within electrical power control equipment.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Durable copper windings ensure efficient operation
  • Manufactured in the USA with robust construction

Specifications

Current Rating
700 A
Frequency
60 Hz
Material
Copper
Mounting Type
Enclosed
Poles
3
Series
Centurion™ R
Voltage Rating
480 VAC or 600 VAC
Package Dimensions (L x W x H)
23 IN x 33.5 IN x 31.2 IN
Package Dimensions (L x W x H)
585 mm x 851 mm x 793 mm
Package Weight (Imperial)
257.000 L
Package Weight (Metric)
117.000 kg
Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60 Hertz

CRX0700CC

Reactor, Three Phase, 700 Horsepower, 3% Impedance, 700 Amperes, Copper Windings, 60 Hertz
KDR, 480V, 600A, 450HP

KDRL3PC5

KDR, 480V, 600A, 450HP
REACTOR LRW250G3N1

LRW250G3N1

REACTOR LRW250G3N1
Reactor, Three Phase, 1000 Horsepower, 5% Impedance, 1200 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX1200DE

Reactor, Three Phase, 1000 Horsepower, 5% Impedance, 1200 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactor, Three Phase, 700 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0900DE

Reactor, Three Phase, 700 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactors, 219 Amperes, 0.096 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0219NE

Reactors, 219 Amperes, 0.096 Millihenries Inductance, 50 Hertz, Enclosed.
Reactor, Three Phase, 900 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz.

CRX0900EC

Reactor, Three Phase, 900 Horsepower, 5% Impedance, 900 Amperes, Copper Windings, 60 Hertz.
Reactor, Three Phase, 600 Horsepower, 5% Impedance, 600 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0600EE

Reactor, Three Phase, 600 Horsepower, 5% Impedance, 600 Amperes, Copper Windings, 60 Hertz, Enclosed.

Frequently Asked Questions

What compliance and approvals do HPS Centurion R reactors meet?

They are compliant with UL, CSA, CE, IEC, and NEMA standards, including UL 508, CSA C22.2 No. 47, and IEC 61558-2-20.

What is the cooling method used for HPS Centurion R reactors?

The cooling method is natural convection.

What is the warranty period for HPS Centurion R reactors?

The product comes with a 10-year limited warranty.

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltage ratings are supported by HPS Centurion R reactors?

Supported system voltage ratings include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The available impedance ratings are 1.5%, 3%, and 5%.

What are the benefits of using HPS Centurion R reactors?

Benefits include mitigating nuisance tripping, extending component life, reducing motor noise and temperature, and minimizing harmonic distortion and line notching.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What is the inductance tolerance for HPS Centurion R reactors?

The inductance tolerance is +15/-10%.

How are HPS Centurion R reactors constructed for reliability?

Reactors have accurately controlled impedance via core gaps, use custom-designed bobbins for mechanical strength, and are vacuum pressure impregnated (VPI) with Polyester Resin to minimize noise.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.