Authorized Hammond Power Distributor
Hammond Power CRX0477AC - 600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.05 Inductance, 60 Hz

Hammond Power CRX0477AC 600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.05 Inductance, 60 Hz

UPC: 803423118914


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0477AC is a 600V Class Iron Core Reactor designed for industrial power applications. This core and coil reactor features an open enclosure and is rated for 477 Amps continuous RMS current. It provides an inductance of 0.05 Henry and operates at 60 Hz. The reactor has a Watts Loss of 420W. Physical dimensions include a width of 13.75 inches (350mm), depth of 10.88 inches (277mm), and height of 14.50 inches (368mm). The reactor weighs 145 lbs (65.0 kg). It is suitable for applications requiring current regulation and harmonic mitigation, with its iron core construction optimized for magnetic flux management. The CRX0477AC is built to standards including UL 508, CSA C22.2 No. 47, and IEC 61558-1, IEC 61558-2-20.
  • 600V Class Iron Core Reactor
  • 477 Amps Continuous RMS Current Rating
  • 0.05 Henry Inductance
  • 60 Hz Operating Frequency
  • Open Enclosure Design
  • Weight: 145 lbs (65.0 kg)
  • Manufactured in the USA

Specifications

Amperage Rating
477 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
477 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
14.5 in
Impedance
0.03
Inductance
0.05 H
Input Voltage
480 Volt
Length
10.88 in
Material
Iron Core
Mounting
Floor Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
13.75 in
Package Dimensions (L x W x H)
14.5 IN x 13.75 IN x 10.88 IN
Package Dimensions (L x W x H)
36.83 cm x 34.925 cm x 27.6352 cm
Package Weight (Imperial)
145.000 L
Package Weight (Metric)
65.772 kg
600V Class Iron Core Reactor, Core and Coil, 515 Amps, 0.05 Inductance, 60 Hz

CRX0515AC

600V Class Iron Core Reactor, Core and Coil, 515 Amps, 0.05 Inductance, 60 Hz
TCI, S-G, Std, 3-Ph

KLR420DCB5

TCI, S-G, Std, 3-Ph
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.07 Inductance, 60 Hz

CRX0382AE

600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.07 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 472 Amps, 0.10 Inductance, 60 Hz

CRX0472BC

600V Class Iron Core Reactor, Core and Coil, 472 Amps, 0.10 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 343 Amps, 0.05 Inductance, 60 Hz

CRX0343CE

600V Class Iron Core Reactor, Enclosed, 343 Amps, 0.05 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 414 Amps, 0.08 Inductance, 60 Hz

CRX0414BC

600V Class Iron Core Reactor, Core and Coil, 414 Amps, 0.08 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.08 Inductance, 60 Hz

CRX0477BC

600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.08 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What impedance ratings are available for the reactors?

The impedance ratings available are 1.5%, 3%, and 5%.

What standards are HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed, CSA Certified, and IEC 61558-2-20.

How is audible noise minimized in these reactors?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What is the inductance tolerance for the reactors?

The inductance tolerance is +15/-10%.

What is the cooling method used for these reactors?

The cooling method is natural convection.

What is the warranty period for HPS Centurion R reactors?

The product comes with a 10-year limited warranty.

How do these reactors protect motors and AC drives?

They protect motors and AC drives by attenuating voltage and current transients that can cause nuisance tripping and minimizing harmonic current levels.

What are the benefits of using HPS Centurion R reactors?

Benefits include mitigating nuisance tripping, extending motor life, reducing audible noise, minimizing harmonic distortion, and reducing line notching.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.