Authorized Hammond Power Distributor
Hammond Power CRX0382AE - 600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.07 Inductance, 60 Hz

Hammond Power CRX0382AE 600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.07 Inductance, 60 Hz

UPC: 803423119546


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0382AE is a 600V Class Iron Core Reactor designed for industrial power systems. This enclosed unit offers a continuous current rating of 382 Amps and a nominal inductance of 0.07 Henries at a 60 Hz operating frequency. Its robust construction ensures reliable operation in demanding environments. The CRX0382AE is suitable for applications such as harmonic mitigation, power factor correction, and motor control circuits, where precise current control and system stability are critical. Manufactured in the USA, this reactor adheres to stringent quality standards. The enclosed design provides protection against environmental factors, enhancing its longevity and performance. For applications requiring stable inductive loads and efficient power management, the Hammond Power CRX0382AE provides a dependable solution. Its specifications make it a valuable component for maintaining the integrity and efficiency of electrical infrastructure.
  • 600V Class Iron Core Reactor
  • 382 Amps continuous current rating
  • 0.07 Henries inductance
  • 60 Hz operating frequency
  • Enclosed design for protection

Specifications

Amperage Rating
382 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
382 A
Enclosure
CH5-N1/IP20 - Indoor
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
28.9 in
Impedance
0.03
Inductance
0.07 H
Input Voltage
600 Volt
Length
21.3 in
Material
Iron Core
Mounting
Floor Mount
Mounting Type
Enclosed
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 VAC
Width
28.1 in
Package Dimensions (L x W x H)
28.9 IN x 28.1 IN x 21.3 IN
Package Dimensions (L x W x H)
73.406 cm x 71.374 cm x 54.102 cm
Package Weight (Imperial)
172.000 L
Package Weight (Metric)
78.019 kg
600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.12 Inductance, 60 Hz

CRX0382BE

600V Class Iron Core Reactor, Enclosed, 382 Amps, 0.12 Inductance, 60 Hz
TCI, S-G, Std, 3-Ph

KLR360ECB5

TCI, S-G, Std, 3-Ph
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
600V Class Iron Core Reactor, Core and Coil, 472 Amps, 0.10 Inductance, 60 Hz

CRX0472BC

600V Class Iron Core Reactor, Core and Coil, 472 Amps, 0.10 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 343 Amps, 0.05 Inductance, 60 Hz

CRX0343CE

600V Class Iron Core Reactor, Enclosed, 343 Amps, 0.05 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 414 Amps, 0.08 Inductance, 60 Hz

CRX0414BC

600V Class Iron Core Reactor, Core and Coil, 414 Amps, 0.08 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.08 Inductance, 60 Hz

CRX0477BC

600V Class Iron Core Reactor, Core and Coil, 477 Amps, 0.08 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 4.6 Amps, 3.55 Inductance, 60 Hz

CRX04D6CC

600V Class Iron Core Reactor, Core and Coil, 4.6 Amps, 3.55 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

The HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for the reactors?

The available impedance ratings for the HPS Centurion R reactors are 1.5%, 3%, and 5%.

What is the typical operating frequency for these reactors?

The system frequency for these reactors is 50/60 Hertz.

How do these reactors protect motors and AC drives?

They protect motors and AC drives by attenuating voltage and current transients that can cause nuisance tripping and minimizing harmonic current levels.

What benefits do HPS reactors offer for AC drive applications?

HPS reactors mitigate nuisance tripping, extend motor life, reduce audible noise, moderate line transients, and minimize harmonic distortion.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

What is the warranty period for these reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

What is the inductance tolerance for these reactors?

The inductance tolerance for the HPS Centurion R reactors is +15/-10%.

What is the dielectric strength to ground for the reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.