Hammond Power CP1K6G0050CC Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Enclosure Type…
UPC: 803423190156
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
- It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
- HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
- Typical Power Factor: >95%
- Type 3R enclosure for environmental protection
- Integrated contactor for simplified installation
- Reduces harmonic current distortion by up to 80%
- Achieves true power factor over 95%
- Meets IEEE 519 harmonic requirements
Specifications
Ambient Operating Temperature | 0 to 40 Deg C |
Application | For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants |
Connection Type | Contactor |
Cooling | Natural Convection |
Current Rating | 50 A |
Depth | 23.8 IN |
Enclosure | Type 3R DH2 |
Enclosure Type | Type 3R |
Frequency | 60Hz |
Frequency Rating | 60 HZ |
Height | 28.8 IN |
Impedance | 50A |
Input Current | 46 A |
Length | 23.8 IN |
Mounting | Wall/Ceiling/Floor Mount |
Mounting Style | Floor |
NEMA Rating | Type 3R |
Output Current | 50 A |
Series | CP1K |
Special Features | Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements. |
Standard | cUL Listed (E61431) |
Voltage | 480 V |
Voltage Rating | 480 V |
Voltage Rating | 480V |
Warranty | 3 Years |
Weight | 220 L |
Width | 25.8 IN |
Package Dimensions (L x W x H) | 23.8 IN x 25.8 IN x 28.8 IN |
Package Dimensions (L x W x H) | 604 mm x 655 mm x 731 mm |
Package Weight (Imperial) | 220.000 L |
Package Weight (Metric) | 100.000 kg |

CP1K6G0050C
Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Enclosure Type 3R
CP1P6G0040FC
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Open Style, Contactor
CP1P6G0006FC
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style, Contactor
CP1P6G0049FC
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style, Contactor
CP1P6G0399CC
Passive Harmonic Filters, 400 HorsePower, 600 Volts, 399 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1K6G0061CC
Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0287CC
Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R, ContactorFrequently Asked Questions
What is the typical harmonic current distortion reduction?
The HPS passive harmonic filter reduces harmonic current distortion by 80%, typically to 5% or less at full load.
What power factor does this filter achieve?
The filter corrects true power factor to over 95%.
What standards does this filter meet?
The filter meets IEEE 519 harmonic requirements when operated within designed parameters.
What is the operating voltage range for this filter?
The filter is available for 480VAC or 600VAC +/-10% voltage ratings.
What is the maximum ambient operating temperature?
The maximum ambient operating temperature is up to 50°C.
What is the humidity limit for operation?
The maximum humidity for operation is 95% non-condensating.
What is the storage temperature range?
The storage temperature range is -20°C to +60°C.
What is the efficiency of the filter at full load?
The efficiency is no less than 99% at full load.
What is the overload capability of the filter?
The filter has an overload capability of 150% of rated current for 1 minute.
What is the warranty period for this filter?
The filter comes with a 3-year warranty.
How to Install the HPS Centurion P Passive Harmonic Filter
This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Inspect the unit
Examine the HPS Centurion P Passive Harmonic Filter for any transit damage and verify it against the shipping documents. Report any damages immediately.
- Mount the filter
Secure the passive harmonic filter to a stable surface using the provided mounting brackets and screws. Ensure it is level and has adequate clearance for ventilation.
- Ground the filter
Connect the designated grounding terminal of the filter to a proper ground to ensure safe operation before energizing the unit.
- Make electrical connections
Connect the input and output terminals (A1, B1, C1 for input and A2, B2, C2 for output) to the corresponding phases of the power supply and load, following local electrical codes.
- Verify connections
Use a multimeter to check that all connections are secure and that there are no short circuits before proceeding to energize the filter.
- Energize the filter
Turn on the upstream circuit breaker to energize the HPS Centurion P Passive Harmonic Filter. Monitor for any unusual sounds or indicators.
- Perform initial testing
Use a power quality analyzer to measure baseline parameters such as total harmonic distortion and power factor before and after connecting the filter to validate its performance.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.