Authorized Hammond Power Distributor
Hammond Power CD1X0007E - dV/dT filter 7 amperes up to 600 volts type 1
More images

Hammond Power CD1X0007E dV/dT filter 7 amperes up to 600 volts type 1

UPC: 803423168056


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CD1X0007E is a dV/dT filter designed for industrial applications. This unit is rated for 7 amperes and operates up to 600 volts, featuring a Type 1 enclosure. It is specifically engineered for use between variable frequency drives (VFDs) and motors, particularly when longer cable lengths are employed. By mitigating voltage spikes, the dV/dT filter protects motor windings from premature failure caused by the high-frequency switching inherent in VFD operation. This enhances motor longevity and system reliability. Manufactured by Hammond Power, this filter is a crucial component for VFD-motor systems requiring enhanced protection. Origin: FR. UNSPSC: 83101808. SKU: CD1X0007E.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Type 1 enclosure for industrial use
  • Mitigates voltage spikes and protects motor windings

Specifications

Altitude
<1000 m
Ambient Operating Temperature
-25C to 40C (suitable to 50C) Deg C
Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
7 A
Enclosure
Type 1
Height
5.5 in
Inverter Operating Frequency
up to 60Hz
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Inverter Switching Frequency
2kHz - 4kHz
Length
6 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
NEC 480 HP
3
NEC 600 HP
5
Peak Voltage
at Motor: 150% of DC bus voltage
Special Features
Peak Voltage at Motor: 150% of DC bus voltage
Standard
cUL
System Voltage
up to 600V
Voltage Rating
up to 600V
Voltage Rating
600 V
Watts Loss
180
Weight
4 lbs
Width
8 in
Package Dimensions (L x W x H)
6 IN x 8 IN x 5.5 IN
Package Dimensions (L x W x H)
152.4 mm x 203.2 mm x 139.7 mm
Package Weight (Imperial)
4.000 L
Package Weight (Metric)
1.800 kg
dV/dT filter 4 amperes up to 600 volts type 1

CD1X0004E

dV/dT filter 4 amperes up to 600 volts type 1
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style

CP1P6G0049F

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style
dV/dT filter 45 amperes up to 600 volts type 1

CD1X0045E

dV/dT filter 45 amperes up to 600 volts type 1
Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0074FC

Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0020CC

Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0241FC

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0180CC

Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

Frequently Asked Questions

What is the primary purpose of the HPS Centurion D1 dV/dT filter?

The filter is designed for use between VFDs and motors with long cables to mitigate high frequency components and voltage spikes.

How does the dV/dT filter protect motors?

It protects motors by slowing the voltage increase rate and minimizing damaging peak voltages in windings and cables.

What are typical applications for the Centurion D1 series dV/dT filters?

Typical applications include Oil & Gas Pumps, Wastewater Treatment Plants, HVAC Systems, Pulp & Paper, and Irrigation Fields.

What is the system voltage rating for these dV/dT filters?

The system voltage rating is up to 600V, suitable for 480V and 600V applications.

What is the current rating range for HPS dV/dT filters?

The current rating ranges from 2A to 108A, with higher ratings available upon consultation with HPS.

What is the maximum recommended motor lead length for these filters?

The maximum recommended motor lead length is 600 ft, though longer lengths may be possible with HPS consultation.

What is the ambient operating temperature range for the dV/dT filters?

The ambient operating temperature range is -25°C to 40°C, suitable for operation up to 50°C.

What type of enclosure do these dV/dT filters typically have?

The filters are available in an Open Frame (Type 1) enclosure.

What is the voltage drop across the dV/dT filter?

The voltage drop across the filter is less than 3%.

What is the inverter switching frequency range for these filters?

The inverter switching frequency range is 2kHz to 4kHz.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. If damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Securely mount the dV/dT filter to a suitable surface using the provided mounting screws. Ensure it is installed in a dry area with adequate ventilation.

  3. Connect wiring

    Connect the filter's terminals A1, B1, and C1 to the output phases U, V, and W of the variable frequency drive. Connect terminals A2, B2, and C2 to T1, T2, and T3 of the motor. Ensure all connections are tight and secure.

  4. Ground the unit

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before energizing the unit.

  5. Verify connections

    Before energizing the filter, use a multimeter to check that all electrical connections are tight and that there is no moisture present in the unit. Perform an insulation resistance test if moisture exposure is suspected.

  6. Energize the filter

    Once all checks are complete and the unit is confirmed to be dry, restore power to the dV/dT filter and monitor for any unusual sounds or overheating.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.