Authorized Hammond Power Distributor
Hammond Power CD1X0004E - dV/dT filter 4 amperes up to 600 volts type 1
More images

Hammond Power CD1X0004E dV/dT filter 4 amperes up to 600 volts type 1

UPC: 803423168032


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Hammond Power CD1X0004E Type 1 dV/dT filter, 4A, 600V, SKU CD1X0004E. Designed for VFD-to-motor installations with long cable runs. Reduces voltage spikes and dV/dT at motor terminals to extend insulation life and prevent premature failure from VFD switching. Type 1 enclosure protects against solid foreign objects. Specs: 4A current, 600V operation, 8.13" H x 10.00" W x 8.00" D.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Reduces dV/dT and voltage spikes at motor terminals
  • Extends motor insulation life and prevents premature failure

Specifications

Altitude
<1000 m
Ambient Operating Temperature
-25C to 40C (suitable to 50C) Deg C
Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
4 A
Enclosure
Type 1
Height
5.5 in
Inverter Operating Frequency
up to 60Hz
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Inverter Switching Frequency
2kHz - 4kHz
Length
6 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
NEC 480 HP
2
NEC 600 HP
3
NEMA Rating
Type 1
Peak Voltage
at Motor: 150% of DC bus voltage
Series
CD1X
Special Features
Peak Voltage at Motor: 150% of DC bus voltage
Standard
cUL
System Voltage
up to 600V
Voltage Rating
up to 600V
Voltage Rating
600 V
Watts Loss
175
Weight
4 lbs
Width
8 in
Package Dimensions (L x W x H)
6 IN x 8 IN x 5.5 IN
Package Dimensions (L x W x H)
152.4 mm x 203.2 mm x 139.7 mm
Package Weight (Imperial)
4.000 L
Package Weight (Metric)
1.800 kg
dV/dT filter 3 amperes up to 600 volts type 1

CD1X0003E

dV/dT filter 3 amperes up to 600 volts type 1
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
dV/dT filter 45 amperes up to 600 volts open style

CD1X0045F

dV/dT filter 45 amperes up to 600 volts open style
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Open Style

CP1P6G0040F

Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Open Style
dV/dT filter 35 amperes up to 600 volts open style

CD1X0035F

dV/dT filter 35 amperes up to 600 volts open style
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style

CP1P6G0049F

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style
dV/dT filter 45 amperes up to 600 volts type 1

CD1X0045E

dV/dT filter 45 amperes up to 600 volts type 1
Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0074FC

Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor

Frequently Asked Questions

What is the current rating of the CD1X0004E filter?

The Hammond Power CD1X0004E dV/dT filter has a current rating of 4 amperes.

What is the maximum operating voltage for this filter?

This dV/dT filter is designed to operate up to 600 volts.

What type of enclosure does the CD1X0004E have?

The CD1X0004E features a Type 1 enclosure, which provides protection against solid foreign objects.

What is the primary function of a dV/dT filter?

A dV/dT filter mitigates voltage spikes and reduces the rate of voltage rise at motor terminals, protecting motor insulation.

What are the dimensions of the Hammond Power CD1X0004E?

The dimensions of the CD1X0004E are approximately 8.13 inches in height, 10.00 inches in width, and 8.00 inches in depth.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Securely mount the dV/dT filter to a suitable surface using the provided mounting screws. Ensure it is positioned in a dry area with adequate ventilation.

  3. Connect the wiring

    Connect the output phases A1, B1, and C1 to the corresponding U, V, and W terminals on the variable frequency drive. Connect A2, B2, and C2 to T1, T2, and T3 of the motor, ensuring all connections are tight and secure.

  4. Ground the unit

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before proceeding.

  5. Check for moisture

    Before energizing, check the dV/dT filter for any signs of moisture. If moisture is suspected, dry the unit using warmed air for at least 24 hours.

  6. Perform final checks

    Verify that all electrical connections are tight and that the unit is free from any foreign objects. Replace all covers and doors before energizing the filter.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.