Authorized Danfoss Distributor
Danfoss 132H2225 - VLT® Soft Starter MCD 500/600, 125 HP, 215 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2

Danfoss 132H2225 VLT® Soft Starter MCD 500/600, 125 HP, 215 A, 200-525 V, 110-240 V control…

Alternate Item Number: MCD60215CT5S2X00CV2


Documents & Media
Installation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® Soft Starter MCD 600 (SKU: 132H2225) is a high-performance motor control solution designed for fixed-speed applications up to 125 HP (215 A continuous) at 200-525 VAC mains. This non-bypassed unit features continuous SCR conduction for frequent starting duty, making it ideal for pumps, fans, compressors, and conveyors where starting current or water hammer is a concern. Unlike bypassed models, the MCD 600 maintains SCR conduction during operation, eliminating the need for external bypass contactors while ensuring reliable performance under heavy-duty cycles. Key specifications include a control voltage range of 110-240 VAC, separate from the motor circuit, and an IP00 open chassis design for internal enclosure mounting. The frame S2 size accommodates high-current applications, with a compact footprint that saves panel space. The MCD 600 supports advanced features like Adaptive Acceleration Control (AAC) for optimized start profiles, pump clean/reverse functions for fluid handling systems, and extensive motor/starter protections to maximize uptime. Communication flexibility is enhanced with optional Ethernet, serial, and fieldbus modules (Modbus, PROFIBUS, EtherNet/IP, DeviceNet), while the VLT® Local Control Panel (LCP 601) provides plug-and-play parameter setup and monitoring in eight languages. This unit is configured to order with the type code MCD60215CT5S2X00CV2, ensuring precise alignment with your application requirements. For installations requiring external bypass solutions, the MCD 600’s continuous operation design delivers consistent performance without derating, even under frequent start/stop cycles. Compatible with WinSTART software for rating adjustments, this soft starter is a proven choice for industrial automation where reliability and efficiency are critical.
  • 125 HP (215 A continuous) at 200-525 VAC mains
  • Non-bypassed design for continuous SCR conduction and frequent starting duty
  • Control voltage: 110-240 VAC (separate from motor circuit)
  • IP00 open chassis for internal enclosure mounting (frame S2)
  • Supports Adaptive Acceleration Control (AAC) and pump clean/reverse functions
  • Optional fieldbus communication (Modbus, PROFIBUS, EtherNet/IP, DeviceNet)
  • VLT® Local Control Panel (LCP 601) for parameter setup and monitoring

Specifications

Bypass
Non-bypassed (continuous)
Continuous Amps
215
Control Voltage
110-240 V
Enclosure
0
Frame Size
S2
Horsepower
125 HP
Phase
3
Phases and main voltage
200-525 V
Product Line
500 Volt without Built in Bypass
Product Line
VLT® Soft Starter (MCD series)
Series
SOFT STARTERS
Type Code
MCD60215CT5S2X00CV2
Voltage
500 Volt without Built in Bypass
VLT® Soft Starter MCD 500/600, 125 HP, 244 A, 200-525 V, 24 V control, bypassed, IP00, frame S2

136G7342

VLT® Soft Starter MCD 500/600, 125 HP, 244 A, 200-525 V, 24 V control, bypassed, IP00, frame S2
STANDARD PANEL GPH2125QC2001 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 125 HP; Main voltage 230 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light, Fault Light and Keypad; Enclosure rating Type 4

GPH2125QC2001

STANDARD PANEL GPH2125QC2001 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 125 HP; Main voltage 230 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light, Fault Light and Keypad; Enclosure rating Type 4
PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.

X125-B4-48-ND

PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.
MTR DIN MT SOFT START 480V 12A

RSE4812-B

MTR DIN MT SOFT START 480V 12A
VLT® Soft Starter MCD 500/600, 150 HP, 31 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2226

VLT® Soft Starter MCD 500/600, 150 HP, 31 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 200 HP, 343 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2227

VLT® Soft Starter MCD 500/600, 200 HP, 343 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 300 HP, 448 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2229

VLT® Soft Starter MCD 500/600, 300 HP, 448 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 100 HP, 23 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2

132H2230

VLT® Soft Starter MCD 500/600, 100 HP, 23 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2

Frequently Asked Questions

What is the voltage range for the VLT® Soft Starter MCD 600?

The VLT® Soft Starter MCD 600 has a mains voltage range of 3 x 200-525 VAC for T5 and 3 x 380-690 VAC for T7.

What is the current range for the VLT® Soft Starter MCD 600?

The current range for the MCD 600 is 20-129 A nominal for IP20 enclosures and 144-1250 A nominal for IP00 enclosures.

Can the soft starter be programmed via PC?

Yes, the soft starter can be programmed via PC using the VLT® Motion Control Tool MCT 10 set-up software.

What is the power range for VLT® Compact Starter MCD 200 series?

The VLT® Compact Starter MCD 200 series covers a power range from 7.5 to 110 kW.

What is the voltage range for VLT® Compact Starter MCD 201 and MCD 202?

These starters operate on 3 x 200 - 575 VAC mains voltage with a control supply of 110-440 V AC or 24 V AC/DC.

Does the soft starter generate harmonics?

No, soft starters generate zero harmonics, eliminating the need for filters and screened cables.

What is the power range for the Eltwin SMC Soft Starter?

The Eltwin SMC soft starter is designed for AC motors up to 11 kW.

What control voltage options are available for the Eltwin SMC Soft Starter?

The Eltwin SMC Soft Starter supports 400-480 V mains voltage and has a control voltage range of 24-480 V AC/DC.

What is the maximum motor size for the MCD 201 and MCD 202 soft starters?

The MCD 201 and MCD 202 soft starters are suitable for motors from 7.5 to 110 kW.

What are the benefits of using a soft starter with integrated bypass?

Integrated bypass offers reduced heat loss, saves panel space compared to external bypass, and allows for faster wiring, saving time and cost.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.