Danfoss 132H2230 - VLT® Soft Starter MCD 500/600, 100 HP, 23 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2

Danfoss 132H2230 VLT® Soft Starter MCD 500/600, 100 HP, 23 A, 200-525 V, 24 V control, non-bypassed…

Alternate Item Number: MCD60160CT5S2X00CV1


Documents & Media
Installation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® Soft Starter MCD 600 (SKU 132H2230) is a high-performance motor control solution for fixed-speed applications up to 100 HP. Rated for 23 A continuous current and 200-525 V mains, this non-bypassed soft starter uses SCRs to control motor ramp-up, reducing starting current and mechanical stress. Ideal for pumps, fans, compressors, and conveyors where water hammer or high inrush current is a concern. The 24 V DC control supply is separate from the motor circuit, ensuring compatibility with standard control systems. Supplied as an open chassis (IP00), it mounts inside a customer-provided enclosure for protection and cooling. The MCD 600 supports frequent starting duty and integrates with Danfoss’s WinSTART software for configuration. With adaptive acceleration control and built-in motor protections, it delivers reliable performance in industrial environments.
  • 100 HP motor capacity with 23 A continuous current rating
  • Non-bypassed design for frequent starting duty and continuous SCR conduction
  • 24 V DC control supply separate from motor circuit (200-525 V mains)
  • Compact IP00 chassis for mounting inside customer enclosures
  • Supports pumps, fans, compressors, and conveyors with soft ramp control

Specifications

Bypass
Non-bypassed (continuous)
Continuous Amps
160
Control Voltage
24 V
Current Rating
23 A
Enclosure
0
Frame Size
S2
Horsepower
100 HP
IP Rating
IP20
Phase
3
Phases and main voltage
200-525 V
Product Line
500 Volt without Built in Bypass
Product Line
VLT® Soft Starter (MCD series)
Series
SOFT STARTERS
Type Code
MCD60160CT5S2X00CV1
Voltage
500 Volt without Built in Bypass
VLT® Soft Starter MCD 500/600, 150 HP, 31 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2226

VLT® Soft Starter MCD 500/600, 150 HP, 31 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S2
PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 50HP/68A, heavy duty class 30 starts for 40HP/60A, SSCR rating of 65kA, 480V and type 4 enclosure.

X50-B4-48-ND

PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 50HP/68A, heavy duty class 30 starts for 40HP/60A, SSCR rating of 65kA, 480V and type 4 enclosure.
SOFT-STARTER SSW050023T2246TPZ WEG specifications: Rated current 23 A; Power supply 220-460 V; Enclosure IP00; Frame 1

SSW050023T2246TPZ

SOFT-STARTER SSW050023T2246TPZ WEG specifications: Rated current 23 A; Power supply 220-460 V; Enclosure IP00; Frame 1
1-PHASE SOFT STARTER 25A UE: 100 - 240 VAC I/P:24V

RGTS24250FV00

1-PHASE SOFT STARTER 25A UE: 100 - 240 VAC I/P:24V
VLT® Soft Starter MCD 500/600, 125 HP, 215 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2

132H2231

VLT® Soft Starter MCD 500/600, 125 HP, 215 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 150 HP, 215 A, 380-690 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2239

VLT® Soft Starter MCD 500/600, 150 HP, 215 A, 380-690 V, 110-240 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 150 HP, 275 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2

132H2232

VLT® Soft Starter MCD 500/600, 150 HP, 275 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 250 HP, 343 A, 380-690 V, 110-240 V control, non-bypassed, IP00, frame S2

132H2241

VLT® Soft Starter MCD 500/600, 250 HP, 343 A, 380-690 V, 110-240 V control, non-bypassed, IP00, frame S2

Frequently Asked Questions

Do soft starters generate harmonics?

No, soft starters generate zero harmonics, eliminating the need for filters and screened cables.

What is the maximum current rating for Danfoss soft starters?

The Danfoss portfolio of soft starters offers ratings up to 1250 A.

How does a soft starter reduce mechanical stress on equipment?

By reducing the starting torque and starting current, soft starters alleviate mechanical stress on motors and other components.

Can soft starters be programmed via a PC?

Yes, soft starters can be programmed using the VLT® Motion Control Tool MCT 10 set-up software.

What are the benefits of using a soft starter with integrated bypass?

Integrated bypass offers reduced heat loss, saves panel space, and reduces wiring time compared to external bypass.

Can the VLT® Soft Starter MCD 600 be controlled remotely?

Yes, the MCD 600 supports remote control via a Local Control Panel (LCP 601) and various communication option cards.

What is the voltage range for the VLT® Soft Starter MCD 600?

The VLT® Soft Starter MCD 600 has a voltage range of 3 x 200-525 VAC (T5) or 3 x 380-690 VAC (T7).

Which Danfoss soft starter models offer integrated bypass functionality?

The VLT® Soft Starter MCD 600 and VLT® Compact Starters MCD 201/202 offer integrated bypass.

What protection features are included in the VLT® Soft Starter MCD 600?

The MCD 600 includes motor thermistor connection, current imbalance, under/overcurrent protection, and phase loss detection.

How does a soft starter help in pump applications?

Soft starters reduce water hammer during soft stop, prevent motor overheating, and detect issues like blocked pipes.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.