ABB Low Voltage Drives P14494-43 Braking Resistor, 21 OHMS, 2000 WATTS, GCE5 Enclosure, 12W x 16D x 5H in, 18 lbs
Alternate Item Number: 3AUA0000041895
UPC: 662348076354
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 21 OHM resistance for effective energy dissipation
- 2000-watt power rating for high-demand applications
- Durable GCE5 enclosure for industrial environments
- Compact dimensions: 12W x 16D x 5H inches
- Manufactured by ABB Low Voltage Drives
Frequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors are used with variable frequency drives to increase braking torque, enabling faster and more controlled braking. They dissipate regenerated power to prevent the bus voltage from exceeding the drive's rated limit.
What is the duty cycle for the resistor applications listed?
The duty cycles listed include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the purpose of braking modules with AC drives?
Braking modules monitor the drive's DC bus and activate external braking resistors as needed. This prevents over-voltage trips and improves the overall performance of the drive system.
What voltage range do ACS150 and ACS355 drives support with Type CR resistors?
ACS150 and ACS355 drives support single-phase 200-240V applications and three-phase 200-240V applications with Type CR resistors for stopping duty.
What are the voltage ratings for ACS250 drives using Type CR resistors?
ACS250 drives are available for single-phase 100-120V and 200-240V applications, as well as three-phase 200-240V and 380-480V applications with Type CR resistors.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch in Type GCE and ED enclosures is used to detect resistor temperature overloads, providing a safety mechanism.
What are the operating voltage ranges for ACS250 UL Type 4X drives?
ACS250 UL Type 4X drives are available for three-phase 200-240V and 380-480V applications, utilizing Type CR resistors for stopping duty.
What type of wire should be used when attaching directly to resistors in Type ED enclosures?
If installing without optional terminal connections in Type ED enclosures, always use 200ºC rated silicone or Teflon wire when attaching directly to resistors.
How are Powerohm Type CR resistors designed for efficient cooling?
Type CR resistors have a nickel-chromium wire coil inside a ceramic fixture, housed in an aluminum case. The coil is electrically isolated but thermally bound to the case for efficient heat transfer and cooling.
What is the conduit knockout size for Type GCE enclosures?
The Type GCE enclosure is machined to include 1/2 inch conduit knockouts for routing standard 90ºC rated wire.