ABB Low Voltage Drives ABB-48431-033 Braking Resistor, 13 OHMS, 3328 WATTS, GCE6 Enclosure, 19W x 10D x 5H in, 18 lbs
Alternate Item Number: 3AUA0000015098
UPC: 662348001127
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 13 OHM resistance for effective braking
- 3328 WATTS power rating for high energy dissipation
- Durable GCE6 enclosure for industrial environments
- Compact dimensions: 19" W x 10" D x 5" H
- Designed for use with ABB Low Voltage Drives
Specifications
Size | 19 x 10 x 5 in |
Frequently Asked Questions
What are the resistance and wattage for a CR resistor for a 1 HP ACS150/355-01U-04A7-2 drive with a 10sec on/50sec off duty cycle?
For a 1 HP ACS150/355-01U-04A7-2 drive with a 10sec on/50sec off duty cycle, the CR resistor is 100 Ohms and 100 Watts.
What are the resistance and wattage for an enclosed resistor for a 3 HP ACS150/355-01U-09A8-2 drive with a 60sec on/180sec off duty cycle?
For a 3 HP ACS150/355-01U-09A8-2 drive with a 60sec on/180sec off duty cycle, the enclosed resistor is 35 Ohms and 820 Watts.
What are the resistance and wattage for a CR resistor for a 1.5 HP ACS250-01U-05A8-1 drive with a 60sec on/180sec off duty cycle?
For a 1.5 HP ACS250-01U-05A8-1 drive with a 60sec on/180sec off duty cycle, the CR resistor is 50 Ohms and 400 Watts.
What are the resistance and wattage for an enclosed resistor for a 5 HP ACS250-03U-18A0-2 drive with a 30sec on/180sec off duty cycle?
For a 5 HP ACS250-03U-18A0-2 drive with a 30sec on/180sec off duty cycle, the enclosed resistor is 35 Ohms and 820 Watts.
What are the resistance and wattage for an enclosed resistor for a 3 HP ACS550-U1-05A4-4 drive with a 60sec on/180sec off duty cycle?
For a 3 HP ACS550-U1-05A4-4 drive with a 60sec on/180sec off duty cycle, the enclosed resistor is 80 Ohms and 800 Watts.
What is the purpose of a braking resistor with VFDs?
Braking resistors dissipate regenerated power to prevent the drive's bus voltage from exceeding its rated limit, especially during faster deceleration or overhauling loads.
What is the voltage range for ACS250 single-phase applications?
ACS250 drives are available for single-phase 100-120 V and 200-240 V applications, all for stopping duty only.
What is the voltage range for ACS550 three-phase applications?
ACS550 drives are available for three-phase 200-240V and 380-480V applications, all for stopping duty only.
What is the voltage range for ACS150 and ACS355 single-phase applications?
These drives are for single-phase 200-240V applications and are designed for stopping duty only.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads and is used to monitor for over-temperature conditions.