- 45Ω resistance for precise braking torque control
- 300W continuous power rating for sustained duty cycles
- GCE1 enclosure for industrial durability and protection
- Compact 12x5x5 inch dimensions, 7 lbs weight for space-efficient installation
- Compatible with ABB low-voltage drives for seamless integration

MPOT-01
Potentiometer with two switches: Start/Stop and Forward/Reverse. Polarity is selected with DIP switches. No external power source is needed for the potentiometer. This option can be used with the Blank Cover, Basic or Advanced Panel.Frequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors are used with variable frequency drives for applications requiring faster deceleration or when motor speeds exceed synchronous speed. They increase braking torque and dissipate regenerated power to prevent bus voltage from exceeding drive limits.
What is the voltage range for ACS150 and ACS355 single-phase applications?
ACS150 and ACS355 drives in single-phase 200-240V applications are designed for stopping duty only.
What are the resistance and wattage for P14494-CR-02 resistor for a 0.5 Hp ACS150/355 drive?
For a 0.5 Hp ACS150/355 drive, the P14494-CR-02 resistor has 200 Ohms and 100 Watts for duty cycles of 3sec on/27sec off and 10sec on/50sec off.
What is the resistance and wattage for P14494-24 resistor for a 1 Hp ACS150/355 drive?
For a 1 Hp ACS150/355 drive, the P14494-24 resistor has 45 Ohms and 300 Watts for duty cycles of 3sec on/27sec off and 10sec on/50sec off.
What are the voltage and application type for ACS250 UL Type 4X drives?
ACS250 UL Type 4X drives are for three-phase 200-240V applications and are designed for stopping duty only.
What is the resistance and wattage for P14494-31 resistor for a 2 Hp ACS250-03U drive?
For a 2 Hp ACS250-03U drive, the P14494-31 resistor has 35 Ohms and 300 Watts for duty cycles of 3sec on/27sec off and 10sec on/50sec off.
What are the voltage and application type for ACS550 drives listed?
The listed ACS550 drives are for three-phase 200-240V applications and are designed for stopping duty only.
What is the resistance and wattage for P14494-CR-04 resistor for a 1 Hp ACS550-U1 drive?
For a 1 Hp ACS550-U1 drive, the P14494-CR-04 resistor has 100 Ohms and 100 Watts for duty cycles of 3sec on/27sec off and 10sec on/50sec off.
What is the resistance and wattage for P14494-15 resistor for a 3 Hp ACS550-U1 drive?
For a 3 Hp ACS550-U1 drive, the P14494-15 resistor has 150 Ohms and 300 Watts for duty cycles of 3sec on/27sec off and 10sec on/50sec off.
What is the voltage range for ACS550 drives in 380-480V applications?
ACS550 drives in three-phase 380-480V applications are designed for stopping duty only.