ABB Low Voltage Drives FDNA-01-KIT The DeviceNet network uses a linear bus topology. Terminating resistors are required on…
Alternate Item Number: 68469341
UPC: 662348075470
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- DeviceNet adapter module for ABB Low Voltage Drives
- Functions as a Class 2 slave device
- Supports Explicit Messaging, Poll-Response, and Change of State/Cyclic services
- Complies with ODVA AC/DC Drive Functional Profile
- Compatible with ABB drives profile
Specifications
Frame Size | 0 |
Height | 3.03 in |
Length | 1.06 in |
Type | ACQ580 DeviceNet adapter |
Weight | 32 lbs./100ft |
Weight | 0.049 lb |
Width | 2.52 IN |

FPBA-01-KIT
PROFIBUS is an open serial communication standard that enables data exchange between all kinds of automation components. The physical transmission medium of the bus is a twisted pair cable (according to the RS-485 standard). The maximum length of the bus cable is 100 to 1200 meters, depending on the selected transmission rate. Up to 31 stations can be connected to the same PROFIBUS system without the use of repeaters.
NBBM-V230-A300
Braking Chopper, Nominal AC Line Voltage 200-240V, Minimum 0.87 OHM, RMS Continuous Load Current 300 A
NBBM-V600-A1200
Braking Chopper, Nominal AC Line Voltage 500-600V, Minimum 0.53 OHM, RMS Continuous Load Current 1200 A
NBBM-V600-A900
Braking Chopper, Nominal AC Line Voltage 500-600V, Minimum 0.71 OHM, RMS Continuous Load Current 900 A
RTAC-01-KIT
The Pulse Encoder Interface module offers a differential or single ended interface for a digital pulse encoder. The module is capable of operating from either a 15 or 24VDC signal with a max frequency of 200kHz. This option uses 55 mA of the available 250 mA power supply. When the drive’s internal power supply is used to power the encoder, additional options may not be installed. Check the encoder’s power supply requirements prior to installation.
DCS800-D6-BUSBAR-QTY-5-KIT
Busbar kit for multiple wire connections on frame D6 DCS800 module drives. The kit includes five (5) tinned copper busbar ears and mounting hardware. Dimension 250x140x100mm (LxHxD) and 10mm thick.
RDNA-01-KIT
The DeviceNet network uses a linear bus topology. Terminating resistors are required on each end of the trunk line. Drop lines as long as 6 meters (20 feet) each are permitted, allowing one or more nodes to be attached. DeviceNet allows branching structures only on drop lines.
DCS800-DEMOCASE
Powered by 115VAC the DCS800 Democase includes a DCS800 frame D1 drive mounted on a panel. Included is a motor with analog tachometer and an I/O board.Frequently Asked Questions
What is the maximum number of devices for FCAN-01?
The FCAN-01 adapter supports a maximum of 127 devices on the network.
What is the baud rate range for FCAN-01?
The FCAN-01 supports baud rates from 10 kbit/s up to 1 Mbit/s.
What is the maximum number of devices for FENA-01?
The FENA-01 adapter supports nearly unlimited devices on the network.
What is the baud rate for FENA-01 on EtherNet/IP?
The FENA-01 supports 10, 100, and 100 Mbit/s for EtherNet/IP.
What is the maximum number of devices for FPBA-01?
The FPBA-01 supports 32 devices per segment, with a total of 126 devices.
What is the baud rate range for FPBA-01?
The FPBA-01 supports baud rates from 9.6 kbit/s to 12 Mbit/s.
What is the maximum number of devices for Modbus-RTU adapters?
Modbus-RTU adapters like FMBA-01, FSCA-01, and FRSA-00 support 247 devices.
What CANopen standard does the FCAN-01 adapter fulfill?
The FCAN-01 adapter fulfills the CiA (CAN in Automation) standard DSP 402.
What communication profiles does the FPBA-01 support?
The FPBA-01 supports PROFIdrive, ABB Drives, Transparent 16, and Transparent 32 communication profiles.
What Modbus-RTU adapter modules are available?
The available Modbus-RTU adapter modules are FMBA-01, FSCA-01, and FRSA-00.