ABB Low Voltage Drives ACS550-PD-178A-2 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000010288
UPC: 662348045763
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 60 HP, 178A, 240VAC, 3-Phase General Purpose Drive
- NEMA 1 / UL Type 1 (IP21) Enclosure for Dust and Light Splash Protection
- Includes Disconnect Switch and Fuses for Enhanced Safety
- Wall-Mounted Design with Advanced Control Panel
- Robust Construction for Industrial Applications
Specifications
Connection Type | 3-Phase Input, 3-Phase Output |
Connection Type | 3-phase |
Connection Type | 3-Phase Input/Output |
Current Rating | 178 A |
IP Rating | IP21 |
Mounting Type | Wall-mounted |
NEMA Rating | Type 1 |
Nema Rating | NEMA 1 |
Nema Rating | NEMA 1 / UL Type 1 |
Poles | 3-Phase |
Series | ACS550 |
Size | 47.7 in x 28.1 in x 19 in |
Voltage Rating | 240 Vac |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the voltage and power range for ACS550 standard drives?
The drives are available in 3-phase options: 208-240V (0.75-100Hp), 380-480V (1-550Hp), and 500-600V (1.5-150Hp).
What is the operating frequency range for the ACS550 drives?
The input power connection frequency range is 48 to 63 Hz, and the motor connection frequency range is 0 to 500 Hz.
What serial communication protocol is built into the ACS550 drives?
The drives have a built-in Modbus RTU protocol for serial communication via RS 485.
What are the acceleration and deceleration time ranges for the ACS550 drives?
Acceleration and deceleration times can be set from 0.1 to 1800 seconds.
What is the power factor of the ACS550 drives?
The power factor for the ACS550 drives is 0.98.
What is the maximum switching voltage for the relay outputs?
The maximum switching voltage for the three relay outputs is 250 V AC/30 V DC.
What are the standard features included with ABB standard drives?
Standard features include a swinging choke for harmonic reduction, an integral EMC filter, and a control panel.
What types of control connections are available on the ACS550 drives?
The drives offer two analog inputs, two analog outputs, six digital inputs, and three relay outputs.
What is the auxiliary voltage provided by the ACS550 drives?
The auxiliary voltage is 24 V DC ±10%, with a maximum current of 250 mA.
What environmental conditions are suitable for operating the ACS550 drives?
The drives operate in ambient temperatures of 15 to 40°C (5 to 104°F) and relative humidity below 95% (without condensation).