ABB Low Voltage Drives ACS550-PD-06A6-2 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000010276
UPC: 662348044933
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 1.5 HP, 240VAC, 6.6A 3-phase output with 208-240V input range
- NEMA 1 / UL Type 1 (IP21) enclosure for dust and light splash protection
- Built-in disconnect switch with fuses and advanced control panel
- Supports 600 cycles/h (general) / 1200 cycles/h (motor) switching frequency
- Dimensions: 28.7 in x 7.8 in x 11.2 in, Weight: 33 lbs
Specifications
Connection Type | 3-Phase Input/Output |
Current Rating | 6.6 A |
IP Rating | IP21 |
Mounting Type | Wall-mounted |
NEMA Rating | Type 1 |
Nema Rating | NEMA 1 |
Nema Rating | NEMA 1 / UL Type 1 |
Poles | 3-Phase |
Series | ACS550 |
Size | 28.7 in x 7.8 in x 11.2 in |
Voltage Rating | 240 Vac |
Package Dimensions (L x W x H) | 51 IN x 12 IN x 18 IN |
Package Dimensions (L x W x H) | 129.54 cm x 30.48 cm x 45.72 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the voltage and power range for 3-phase input?
It supports 3-phase, 208 to 240 V (0.75-100Hp), 380 to 480 V (1-550Hp), and 500 to 600 V (1.5-150Hp).
What is the operating frequency range for the motor connection?
The motor connection frequency range is from 0 to 500 Hz.
What are the acceleration and deceleration time limits?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
What analog input signals are supported?
It supports voltage signals from 0 (2) to 10 V and current signals from 0 (4) to 20 mA.
What is the auxiliary voltage output?
The auxiliary voltage output is 24 V DC ±10%, with a maximum current of 250 mA.
How many digital inputs are available?
There are six digital inputs available, supporting 12 V to 24 V DC with PNP and NPN configurations.
What are the specifications for the relay outputs?
Relay outputs can switch up to 250 V AC/30 V DC, with a maximum current of 6 A/30 V DC.
What serial communication protocol is built-in?
The drive has a built-in RS 485 serial communication with Modbus RTU protocol.
What is the acceptable ambient temperature range for operation?
The ambient temperature range for operation is 15 to 40°C (5 to 104°F), derated above 40°C.
What is the maximum relative humidity allowed?
The relative humidity must be lower than 95%, without condensation.