ABB Low Voltage Drives ACS550-PD-012A-2 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000010278
UPC: 662348043721
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 3 HP, 240VAC (208-240V range) with 11.8A output current
- NEMA 1 / UL Type 1 (IP21) enclosure for dust and light splash protection
- Integrated disconnect switch and fuses for enhanced safety
- Wall-mounted design with compact footprint (28.7 x 7.8 x 11.2 in) and 33 lb weight
- 3-phase input/output for standard industrial power systems
Specifications
Package Dimensions (L x W x H) | 51 IN x 12 IN x 18 IN |
Package Dimensions (L x W x H) | 129.54 cm x 30.48 cm x 45.72 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What are the voltage and power ranges for ABB standard drives?
The drives support 3-phase input power with ranges of 208-240V (0.75-100Hp), 380-480V (1-550Hp), and 500-600V (1.5-150Hp).
Which communication protocols are built-in?
The drives have a built-in Modbus RTU protocol for serial communication via RS 485.
Does the drive have features for harmonic reduction?
Yes, it features a patented swinging choke for superior harmonic reduction and an AC line reactor.
What is the frequency range for the input power?
The input power frequency range for these drives is 48 to 63 Hz.
What motor connection frequencies can these drives support?
The drives can support motor connection frequencies from 0 to 500 Hz.
What is the auxiliary voltage provided by the drives?
The drives provide an auxiliary voltage of 24 V DC ±10%, with a maximum current of 250 mA.
What product compliance and approvals do these drives have?
The drives have UL, cUL, CSA, CE, C-TICK, and GOST-R approvals, and meet Low Voltage, Machinery, and EMC Directives.
What are the environmental operating temperature limits?
The ambient temperature range is 15 to 40°C (5 to 104°F), with derating required from 40 to 50°C (104 to 122°F).
What is the maximum relative humidity for operation?
The relative humidity must be lower than 95%, without condensation.
What are the acceleration and deceleration time ranges?
Acceleration and deceleration times can be set from 0.1 to 1800 seconds.