Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ABB-48431-154 - Braking Resistor, 5.3 OHMS, 1717.2 WATTS, GCE5 Enclosure, 12W x 16D x 5H in, 18 lbs

ABB Low Voltage Drives ABB-48431-154 Braking Resistor, 5.3 OHMS, 1717.2 WATTS, GCE5 Enclosure, 12W x 16D x 5H in, 18 lbs

Alternate Item Number: 3AUA0000015355

UPC: 662348001509


Documents & Media
Technical DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Braking Resistor (SKU: ABB-48431-154) – 5.3Ω, 1717.2W resistor for dynamic braking in industrial motor control. Converts regenerative energy to heat during deceleration, protecting drives and motors from overvoltage. Dimensions: 12" W x 16" D x 5" H. Weight: 18 lbs. Optimized for ABB Low Voltage Drives, specifically ACS800-PC/U7 series, supporting braking duty cycles of 30s on/180s off or 60s on/180s off. Compatible with ABB braking modules NBBM-V460-A300 and NBBM-V460-A600. Applications: conveyor systems, cranes, pumps, high-inertia loads requiring rapid deceleration. Dissipates braking energy efficiently, reducing mechanical stress on motors and extending drive component lifespan, minimizing downtime and maintenance costs. Distributed by Gross Automation. Technical support available for integration and troubleshooting.
  • 5.3Ω resistance, 1717.2W power rating for dynamic braking applications
  • Compact dimensions: 12" W x 16" D x 5" H, 18 lbs weight
  • Compatible with ABB ACS800-PC/U7 drives and NBBM-V460 braking modules
  • Supports 30s/180s or 60s/180s duty cycles for high-inertia loads
  • Weight: 18 lbs
  • Compatibility: ABB Low Voltage Drives
  • Country of origin: US
  • Distributed by Gross Automation
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
HMI door mounting kit with 2M cable

181B0399

HMI door mounting kit with 2M cable
CONDUIT MODULE B(LSLV-S100),DFR2-S100

64150005

CONDUIT MODULE B(LSLV-S100),DFR2-S100
FAN POWER SUPPLY BOARD CFV1D.400V/48V

CFW11SP-12387920

FAN POWER SUPPLY BOARD CFV1D.400V/48V
Braking Resistor, 63 OHMS, 3000 WATTS, GCE8 Enclosure, 19W x 13D x 5H in, 25 lbs

ABB-48431-141

Braking Resistor, 63 OHMS, 3000 WATTS, GCE8 Enclosure, 19W x 13D x 5H in, 25 lbs
Braking Resistor, 21 OHMS, 1500 WATTS, GCE4 Enclosure, 12W x 13D x 5H in, 16 lbs

P14494-42

Braking Resistor, 21 OHMS, 1500 WATTS, GCE4 Enclosure, 12W x 13D x 5H in, 16 lbs
Braking Resistor, 13 OHMS, 1433.25 WATTS, GCE4 Enclosure, 12W x 13D x 5H in, 16 lbs

ABB-48431-030

Braking Resistor, 13 OHMS, 1433.25 WATTS, GCE4 Enclosure, 12W x 13D x 5H in, 16 lbs
Braking Resistor, 21 OHMS, 1050 WATTS, GCE3 Enclosure, 12W x 10D x 5H in, 13 lbs

P14494-41

Braking Resistor, 21 OHMS, 1050 WATTS, GCE3 Enclosure, 12W x 10D x 5H in, 13 lbs

Frequently Asked Questions

What is the resistance and wattage for a CR resistor for a 1 HP ACS150/355-01U-04A7-2 drive with a 10sec on/50sec off duty cycle?

For a 1 HP ACS150/355-01U-04A7-2 drive with a 10sec on/50sec off duty cycle, the CR resistor part number is P14494-CR-04, with 100 Ohms and 100 Watts.

What is the resistance and wattage for an enclosed resistor for a 3 HP ACS150/355-01U-09A8-2 drive with a 60sec on/180sec off duty cycle?

For a 3 HP ACS150/355-01U-09A8-2 drive with a 60sec on/180sec off duty cycle, the enclosed resistor part number is P14494-32, with 35 Ohms and 820 Watts.

What is the resistance and wattage for a CR resistor for a 3 HP ACS250-03U-10A5-2 drive with a 30sec on/180sec off duty cycle?

For a 3 HP ACS250-03U-10A5-2 drive with a 30sec on/180sec off duty cycle, the CR resistor part number is P14494-CR-32, with 50 Ohms and 400 Watts.

What is the resistance and wattage for an enclosed resistor for a 5 HP ACS250-03U-09A5-4 drive with a 60sec on/180sec off duty cycle?

For a 5 HP ACS250-03U-09A5-4 drive with a 60sec on/180sec off duty cycle, the enclosed resistor part number is P14494-20, with 75 Ohms and 600 Watts.

What is the resistance and wattage for a brake module for a 20 HP ACS550-U1-059A-2 drive with a 30sec on/180sec off duty cycle?

For a 20 HP ACS550-U1-059A-2 drive with a 30sec on/180sec off duty cycle, the brake module part number is NBBM-V230-A30, with 5.3 Ohms and 2565 Watts.

What is the resistance and wattage for an enclosed resistor for a 30 HP ACS550-U1-045A-4 drive with a 60sec on/180sec off duty cycle?

For a 30 HP ACS550-U1-045A-4 drive with a 60sec on/180sec off duty cycle, the enclosed resistor part number is ABB-48431-009, with 22 Ohms and 5632 Watts.

What is the purpose of a braking resistor with a variable frequency drive?

A braking resistor increases braking torque for faster deceleration and dissipates regenerated power to prevent bus voltage from exceeding the drive's rated limit.

What are the voltage and phase for ACS250 UL Type 4X drives?

These drives are for three-phase 200-240V applications and are intended for stopping duty only.

What is the voltage range for ACS150 and ACS355 single-phase applications?

These drives are for single-phase 200-240V applications and are intended for stopping duty only.

What is the function of the thermal switch in Type GCE and ED enclosures?

The normally closed thermal switch detects resistor temperature overloads and is used to indicate a potential issue.