ABB Low Voltage Drives ABB-44541 Braking Resistor, 8.42 OHMS, 12590 WATTS, GCE18 Enclosure, 28W x 10D x 10H in, 45 lbs
Alternate Item Number: 3AUA0000015272
UPC: 662348000908
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 8.42Ω resistance with 12,590W power dissipation for high-energy braking
- GCE18 enclosure (IP20) protects against dust and non-conductive contaminants
- Compact 28W x 10D x 10H inch footprint with 45 lb weight for easy installation
- Compatible with ABB ACS880, ACS580, and other VFD series
- USA-made for industrial motor control applications

39524
6-32 Square Drive Round Head Machine Screw Kit, 1/2" (100), 3/4" (90), 1" (65), 1-1/4" (50), 1-1/2" (40) and 2" (35), Zinc PlateFrequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors dissipate regenerated power to prevent bus voltage from exceeding the drive's rated limit, increasing braking torque for faster, controlled braking.
What is the purpose of braking choppers (modules)?
Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and prevent over-voltage trips.
What wire type should be used when connecting directly to resistors in Type ED enclosures?
If installing without optional terminal connections, always use 200ºC rated silicone or Teflon wire when attaching directly to resistors.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads and is used to alert or shut down the system if the temperature becomes too high.
What is the conduit knockout size for Type GCE enclosures?
The Type GCE enclosures have removable 1/2 inch conduit knockouts for routing standard 90ºC rated wire.
What is the purpose of the aluminum case in Type CR resistors?
The aluminum case is corrosion-resistant and helps dissipate heat from the resistor element, allowing for efficient cooling.
What is the typical duty cycle for the listed braking resistors?
The duty cycles listed include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the maximum continuous current rating for terminal connections in Type ED enclosures?
Type ED enclosures supply terminal connections up to 400 amps continuous.
How are Powerohm Type CR resistors constructed?
They feature a nickel-chromium wire helically wound inside a ceramic fixture, placed in a corrosion-resistant aluminum case with high-temperature wire leads.
What are the voltage ratings for ACS250 drives?
ACS250 drives are available for single-phase 100-120V and 200-240V applications, and three-phase 200-240V and 380-480V applications.