Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ABB-44529 - Braking Resistor, 2.02 OHMS, 49941 WATTS, ED4 Enclosure, 30W x 18D x 32H in, 206 lbs

ABB Low Voltage Drives ABB-44529 Braking Resistor, 2.02 OHMS, 49941 WATTS, ED4 Enclosure, 30W x 18D x 32H in, 206 lbs

Alternate Item Number: 3AUA0000015260

UPC: 662348000847


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Braking Resistor, SKU ABB-44529, is engineered for effective energy dissipation in industrial motor control systems. This unit features a resistance of 2.02 OHMS and a substantial power rating of 49941 WATTS, crucial for managing braking energy in variable frequency drive (VFD) applications. Its robust ED4 enclosure provides protection suitable for demanding industrial environments. With physical dimensions of 30 inches wide, 18 inches deep, and 32 inches high, and a weight of 206 lbs, this resistor is built for reliable integration into existing setups. The ABB Braking Resistor from ABB - Low Voltage Drives is designed to enhance the operational safety and extend the lifespan of your motor control equipment by safely dissipating excess energy during braking cycles. Its specifications make it a practical choice for applications requiring precise braking control and energy management. The UNSPSC code for this product is 39122004, and it is manufactured in the US.
  • Resistance: 2.02 OHMS
  • Power Rating: 49941 WATTS
  • Enclosure Type: ED4
  • Dimensions: 30"W x 18"D x 32"H
  • Weight: 206 lbs
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
HMI door mounting kit with 2M cable

181B0399

HMI door mounting kit with 2M cable
CONDUIT MODULE B(LSLV-S100),DFR2-S100

64150005

CONDUIT MODULE B(LSLV-S100),DFR2-S100
FAN POWER SUPPLY BOARD CFV1D.400V/48V

CFW11SP-12387920

FAN POWER SUPPLY BOARD CFV1D.400V/48V
6-32 Square Drive Round Head Machine Screw Kit, 1/2" (100), 3/4" (90), 1" (65), 1-1/4" (50), 1-1/2" (40) and 2" (35), Zinc Plate

39524

6-32 Square Drive Round Head Machine Screw Kit, 1/2" (100), 3/4" (90), 1" (65), 1-1/4" (50), 1-1/2" (40) and 2" (35), Zinc Plate
Braking Resistor, 13.3 OHMS, 6955 WATTS, GCE12 Enclosure, 26.5W x 13D x 5H in, 27 lbs

ABB-44518

Braking Resistor, 13.3 OHMS, 6955 WATTS, GCE12 Enclosure, 26.5W x 13D x 5H in, 27 lbs
Braking Resistor, 8.32 OHMS, 9920 WATTS, GCE18 Enclosure, 28W x 10D x 10H in, 45 lbs

ABB-44520

Braking Resistor, 8.32 OHMS, 9920 WATTS, GCE18 Enclosure, 28W x 10D x 10H in, 45 lbs
Braking Resistor, 8.32 OHMS, 8444 WATTS, GCE15 Enclosure, 26.5W x 16D x 5H in, 38 lbs

ABB-44519

Braking Resistor, 8.32 OHMS, 8444 WATTS, GCE15 Enclosure, 26.5W x 16D x 5H in, 38 lbs

Frequently Asked Questions

What is the purpose of a braking resistor with variable frequency drives?

Braking resistors dissipate regenerated power to prevent bus voltage from exceeding the drive's rated limit, increasing braking torque for faster, controlled braking.

What is the purpose of braking choppers (modules)?

Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and prevent over-voltage trips.

What wire type should be used when connecting directly to resistors in Type ED enclosures?

If installing without optional terminal connections, always use 200ºC rated silicone or Teflon wire when attaching directly to resistors.

What is the function of the thermal switch in Type GCE and ED enclosures?

The normally closed thermal switch detects resistor temperature overloads and is used to alert or shut down the system if the temperature becomes too high.

What is the conduit knockout size for Type GCE enclosures?

The Type GCE enclosures have removable 1/2 inch conduit knockouts for routing standard 90ºC rated wire.

What is the purpose of the aluminum case in Type CR resistors?

The aluminum case is corrosion-resistant and helps dissipate heat from the resistor element, allowing for efficient cooling.

What is the typical duty cycle for the listed braking resistors?

The duty cycles listed include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.

What is the maximum continuous current rating for terminal connections in Type ED enclosures?

Type ED enclosures supply terminal connections up to 400 amps continuous.

How are Powerohm Type CR resistors constructed?

They feature a nickel-chromium wire helically wound inside a ceramic fixture, placed in a corrosion-resistant aluminum case with high-temperature wire leads.

What are the voltage ratings for ACS250 drives?

ACS250 drives are available for single-phase 100-120V and 200-240V applications, and three-phase 200-240V and 380-480V applications.