ABB - Installation Products TB1-15-20-6-R-I-N - Tru-Break, Single-Phase, Retrofit, 15kV/20kA, 600 Amp Bushing, Right Handle Position, MVI1 Compatible, No Motor. Construction: Submersible, Corrosion Resistant, Fully Shielded. Ambient Temperature Range -40 to +65 Degrees C. IEEE C37.74, IEEE 386. Included items: Ground Cable, Linkage Kit, Mounting Kit, Interrupter Handle, Interrupter Locking Arm, Insulating Plug with Cap and Stud.

ABB Installation Products TB1-15-20-6-R-I-N Tru-Break, Single-Phase, Retrofit, 15kV/20kA, 600 Amp Bushing, Right Handle Position…

UPC: 075114428613


Documents & Media
Manufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Tru-Break TB1-15-20-6-R-I-N is a single-phase, retrofit interrupter designed for reliable operation in demanding electrical systems. Manufactured by ABB Installation Products, this unit is rated for 15kV and 20kA, featuring a 600 Amp bushing and a right-hand handle position for convenient operation. Its construction is submersible and corrosion-resistant, ensuring longevity and performance in challenging environments. The fully shielded design provides enhanced safety and protection. Operating within an ambient temperature range of -40 to +65 degrees Celsius, this interrupter meets stringent industry standards, including IEEE C37.74 and IEEE 386. It is compatible with MVI1 systems and does not include a motor. Included accessories for installation and operation are a ground cable, linkage kit, mounting kit, interrupter handle, interrupter locking arm, and an insulating plug with cap and stud. This product is ideal for applications requiring robust and dependable single-phase interruption capabilities, offering peace of mind through its durable construction and adherence to critical electrical safety standards. SKU: TB1-15-20-6-R-I-N.
  • Single-phase retrofit interrupter with 15kV/20kA rating
  • 600 Amp bushing with right-hand handle position
  • Submersible, corrosion-resistant, and fully shielded construction
  • Wide ambient temperature range: -40 to +65 Degrees C
  • Compliant with IEEE C37.74 and IEEE 386 standards

Specifications

Amperage Rating
600 A
Current Rating
20kA
Material
Corrosion Resistant, Fully Shielded
Mounting Type
Submersible
Operating Temperature
-40 to +65 C
Phase
Single Phase
Series
Tru-Break
Size
600 Amp Bushing
Special Features
Right Handle Position
Standard
IEEE 37.74 , IEEE 386
Type
Tru-Break RetroFit
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Tru-Break Interlock Linkage Kit for MVS. Nominal Voltage 15kv, Withstand Current 20kA (SYM), Continuous Current 600 Amps, Handle Position Right, Mating Device MVS3, Electrical Interlock AC. Includes (1) Linkage Bar for MVS, (2) 1/2 inch diameter, 3/4 inch long Clevis Pins, (2) Locking Cotter Pins.

TB15-20-6-R-S-AC

Tru-Break Interlock Linkage Kit for MVS. Nominal Voltage 15kv, Withstand Current 20kA (SYM), Continuous Current 600 Amps, Handle Position Right, Mating Device MVS3, Electrical Interlock AC. Includes (1) Linkage Bar for MVS, (2) 1/2 inch diameter, 3/4 inch long Clevis Pins, (2) Locking Cotter Pins.
Tru-Break, Single-Phase, Retrofit, 27kV/12.5kA, 600 Amp Bushing, Right Handle Position, MVI1 Compatible, No Motor. Construction: Submersible, Corrosion Resistant, Fully Shielded. Ambient Temperature Range -40 to +65 Degrees C. IEEE C37.74, IEEE 386. Included items: Ground Cable, Linkage Kit, Mounting Kit, Interrupter Handle, Interrupter Locking Arm, Insulating Plug with Cap and Stud.

TB1-27-12-6-R-I-N

Tru-Break, Single-Phase, Retrofit, 27kV/12.5kA, 600 Amp Bushing, Right Handle Position, MVI1 Compatible, No Motor. Construction: Submersible, Corrosion Resistant, Fully Shielded. Ambient Temperature Range -40 to +65 Degrees C. IEEE C37.74, IEEE 386. Included items: Ground Cable, Linkage Kit, Mounting Kit, Interrupter Handle, Interrupter Locking Arm, Insulating Plug with Cap and Stud.
Multiway, SubSurface - External Control, 27kV, SwitchGear, 3-Phase, 4-Ways, 2 Source Ways - 3-Phase MVS switch with motor and voltage Sensors, 2-Load Way - 3-Phase MVI Fault Interrupter. Source Way Interface - 600 Amp Bushing, Load Way Interface - 200 Amp Bushing Well, Source and Load Controls - SEL751A Relay - Submersible. Spanish Labels and Instructions.

MS3242H2P62YYXXXS000

Multiway, SubSurface - External Control, 27kV, SwitchGear, 3-Phase, 4-Ways, 2 Source Ways - 3-Phase MVS switch with motor and voltage Sensors, 2-Load Way - 3-Phase MVI Fault Interrupter. Source Way Interface - 600 Amp Bushing, Load Way Interface - 200 Amp Bushing Well, Source and Load Controls - SEL751A Relay - Submersible. Spanish Labels and Instructions.
Multiway, SubSurface - External Control, 27kV, SwitchGear, 3-Phase, 5-Ways, 2 Source Ways - 3-Phase MVS switch with motor and voltage Sensors, 3-Load Way - 3-Phase MVI Fault Interrupter. Source Way Interface - 600 Amp Bushing, Load Way Interface - 200 Amp Bushing Well, Source and Load Controls - SEL751A Relay - Submersible. Spanish Labels and Instructions.

MS3252H3P62YYXXXS000

Multiway, SubSurface - External Control, 27kV, SwitchGear, 3-Phase, 5-Ways, 2 Source Ways - 3-Phase MVS switch with motor and voltage Sensors, 3-Load Way - 3-Phase MVI Fault Interrupter. Source Way Interface - 600 Amp Bushing, Load Way Interface - 200 Amp Bushing Well, Source and Load Controls - SEL751A Relay - Submersible. Spanish Labels and Instructions.
Tru-Break Interlock Linkage Kit for MVI, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amps, Handle Position: Right, Mating Device: MVI3, Electrical Interlock: DC

TB15-20-6-R-I-DC

Tru-Break Interlock Linkage Kit for MVI, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amps, Handle Position: Right, Mating Device: MVI3, Electrical Interlock: DC
Multi-Way Switchgear, Single Sided Padmount, 3-Phase, 38.0kV/12.5kA, 3-Way, 1 Source Way, 3-Phase MVS Switch, 2 Load Way - 3-Phase MVS Switch, Source Way Interface - 600 Amps Bushing Interface, Load Way Interface - 600 Amps Bushing Interface, Source Side Control Type and Logic - None, Load Side Control Type - None. No Solid Dielectric PT to Power the SEL Control, Cam-Op and Integral Position Indicator - None, Mild Steel, Munsell Green 7GY 3.29/1.5 and Round Ground Bar. English Labels and Instructions.

MP3331T2T66XXXXAE000

Multi-Way Switchgear, Single Sided Padmount, 3-Phase, 38.0kV/12.5kA, 3-Way, 1 Source Way, 3-Phase MVS Switch, 2 Load Way - 3-Phase MVS Switch, Source Way Interface - 600 Amps Bushing Interface, Load Way Interface - 600 Amps Bushing Interface, Source Side Control Type and Logic - None, Load Side Control Type - None. No Solid Dielectric PT to Power the SEL Control, Cam-Op and Integral Position Indicator - None, Mild Steel, Munsell Green 7GY 3.29/1.5 and Round Ground Bar. English Labels and Instructions.
Tru-Break, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amp, Handle Position: Right, Mating Device: None, Electrical Interlock : None, Language: English

TB15-20-6-R-N-N

Tru-Break, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amp, Handle Position: Right, Mating Device: None, Electrical Interlock : None, Language: English
Tru-Break Interlock Linkage Kit for MVS, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amp, Handle Position: Right, Mating Device: MVS3, Electrical Interlock: NONE

TB15-20-6-R-S-N

Tru-Break Interlock Linkage Kit for MVS, Nominal Voltage: 15kV, Withstand Current: 20kA (SYM), Continuous Current: 600 Amp, Handle Position: Right, Mating Device: MVS3, Electrical Interlock: NONE

Frequently Asked Questions

What is the voltage rating of the ABB Tru-Break?

The ABB Tru-Break TB1-15-20-6-R-I-N has a voltage rating of 15kV.

What is the current interrupting capacity?

This Tru-Break interrupter has a current interrupting capacity of 20kA.

What is the bushing amperage rating?

The bushing on this unit is rated for 600 Amps.

What are the construction features of this interrupter?

The interrupter is constructed to be submersible, corrosion-resistant, and fully shielded.

What is the operating temperature range?

The ambient temperature range for operation is -40 to +65 degrees Celsius.

Which IEEE standards does this product meet?

This product meets IEEE C37.74 and IEEE 386 standards.

Is this interrupter compatible with MVI1 systems?

Yes, this interrupter is MVI1 compatible.

Does the unit include a motor operator?

No, this model does not include a motor operator.

What accessories are included with the TB1-15-20-6-R-I-N?

Included items are a ground cable, linkage kit, mounting kit, interrupter handle, interrupter locking arm, and an insulating plug with cap and stud.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.