Authorized ABB Distributor (Installation Products)
ABB - Installation Products STX350-480S - Steel Star Teck XP hazardous location jacketed cable fitting hub size 3-1/2 inches PVC coated.

ABB Installation Products STX350-480S Steel Star Teck XP hazardous location jacketed cable fitting hub size 3-1/2 inches PVC…

UPC: 786209996909


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB STX350-480S is a Steel Star Teck XP hazardous location cable fitting hub, designed for secure and reliable cable termination in potentially explosive atmospheres. This fitting is constructed from durable steel with a PVC coating, offering resistance to corrosive environments. It features a 3-1/2 inch hub size and is part of the Star Teck XP series, which utilizes overlapping sizes to prevent mismatches between cables and fittings in the field. The STX350-480S is suitable for hazardous locations including Class 1 Division 2, Class II Division 2, and Class III. It is engineered for applications where explosion-proof or dust-proof enclosures are required by code. The integral sealing chamber simplifies installation, reducing complexity and time. The disconnectable design further enhances efficiency by minimizing cable preparation. This model handles outer jacket diameters up to 3.910 inches, based on the provided catalog data for the ST350-483 model which shares the 3-1/2 inch hub size and a similar outer jacket diameter range. The Star Teck XP series is available in hub sizes from 1/2 inch to 4 inches, accommodating outer jacket diameters from .525 inches to 4.34 inches.
  • Working with engineers from the petrochemical, oil and gas industries, Thomas & Betts then introduced the STAR TECK XP fitting.
  • With an easy-to-fill, integral sealing chamber and a disconnectable design requiring minimal cable preparation, this fitting became the benchmark for ease of installation in hazardous environments.
  • A line of liquid and putty sealants was also developed at the same time, eliminating the need for the cement sealants used up to this point.
  • Part of the Star Teck XP series with overlapping sizes to prevent mismatches
  • Designed for use with explosion-proof or dust-proof enclosures

Specifications

Application
For Hazardous Locations
Color
Red;Silver
Material
Steel
Material
Steel with PVC Coating
Series
STAR TECK XP
Size
3-1/2 Inches
Standard
CSA 23086
Type
Teck Cable Fittings
Voltage Rating
480 VAC
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
18.0000 L
Package Weight (Metric)
8.1650 kg
Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch

685-UI

Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch
PVC Coated Conduit Body Cover, Form 7, Size 1 Inch/27 Metric, Stamped Steel, Dark Gray

370-G1

PVC Coated Conduit Body Cover, Form 7, Size 1 Inch/27 Metric, Stamped Steel, Dark Gray
KIT GREASE FITTING WITH EXTENSION

GF 250 ODE-W22

KIT GREASE FITTING WITH EXTENSION
Aluminum liquidtight fitting for tray cable. Hub size N.P.T. 1/2 inch Range over jacket is 0.25 to 0.310 inch.

HLT050DATA

Aluminum liquidtight fitting for tray cable. Hub size N.P.T. 1/2 inch Range over jacket is 0.25 to 0.310 inch.
1-1/4 Inch Set Screw Connector, Steel with Nylon Insulated Throat for Use with Rigid/IMC Conduit

8425-TB

1-1/4 Inch Set Screw Connector, Steel with Nylon Insulated Throat for Use with Rigid/IMC Conduit
3 Inch Set Screw Connector, Malleable Iron with Nylon Insulated Throat for Use with Rigid/IMC Conduit

8825-TB

3 Inch Set Screw Connector, Malleable Iron with Nylon Insulated Throat for Use with Rigid/IMC Conduit
2 Inch Steel Penny for Use with Rigid/IMC Conduit

820-TB

2 Inch Steel Penny for Use with Rigid/IMC Conduit
1-1/2 Inch Steel Penny for Use with Rigid/IMC Conduit

819-TB

1-1/2 Inch Steel Penny for Use with Rigid/IMC Conduit

How to Install STX Series Cable Fittings (STX350-480S)

This guide provides step-by-step instructions for installing STX Series Star Teck™ cable fittings, specifically for models like STX350-480S, including cable preparation and liquid sealing compound application. Always verify that all circuits are de-energized before starting installation or maintenance to prevent electrical shock. This product must be installed by a qualified electrician in accordance with national and local electrical codes.

Estimated time: 4h

Tools needed:

Hacksaw, Wrench, Wire strippers, Damp cloth, PPE (gloves, safety glasses)

Supplies needed:

STX Series Cable Fitting (e.g., STX350-480S), Cable (power or shielded data), SC4-KIT-1 LIQUID SEALANT, Fiber damming material

  1. Prepare the Cable

    Determine the working length of conductors required inside the enclosure or device. Remove a portion of the outer jacket to expose the cable armor, then cut the armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation. Trim the outer jacket to adjust the exposed armor strip length as indicated in the product table for your specific fitting.

  2. Assemble Gland Nut and Disassemble Fitting

    Feed the prepared cable through the gland nut opening and push until the cable armor hits the end stop. Tighten the gland nut until you obtain an appropriate seal or to the maximum torque specified in the product table. Ensure the bushing and collar ring seal evenly around the cable’s outer jacket and are flush with the gland nut face, keeping the cable centered for an optimal seal. Disassemble the hub from the body sub-assembly by loosening the union, then unscrew the sealing chamber from the body sub-assembly.

  3. Prepare Conductors

    Trim the inner jacket to a length of 1/8”-3/8” to expose the conductor bundle. For shielded data cables, refer to Section 2 of the original instruction sheet for additional steps, which include removing the outer (overall) shield and filler materials, taking care not to nick or damage inner shields.

  4. Apply Liquid Sealing Compound (SC4-KIT-1)

    Pack the fiber damming material tightly into all voids between conductors and the body, spreading strands of uninsulated grounding conductor where applicable. Screw the sealing chamber back onto the body subassembly until it completely seats. Position the cable/fitting into a vertical position. Mix the SC4-KIT-1 liquid sealing compound following the instructions provided on its package. For STX350-480S and similar larger fittings, fill approximately HALF of the sealing chamber. Wait 2 hours for the compound to set, then fill the rest of the sealing chamber to the top. CAUTION: Remove all excess compound material from outside of the sealing chamber with a damp cloth. Do not use abrasive cleaners that may damage the flame path.

  5. Complete Final Assembly

    Mount the hub in the desired location. After the sealing compound has solidified (approximately 1 hour after the final pour), place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms, ensuring metal-to-metal contact.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.