ABB - Installation Products STX100-468S - Star Teck hazardous location steel jacketed cable fitting. Hub size of 1 inch. Range over jacket from 1.025 - 1.205 inch.

ABB Installation Products STX100-468S Star Teck hazardous location steel jacketed cable fitting. Hub size of 1 inch. Range…

UPC: 786210309545


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products STX100-468S STAR TECK XP hazardous location steel jacketed cable fitting is a precision-engineered solution for secure cable termination in classified hazardous areas. This 1-inch hub size fitting is specifically designed to accommodate jacketed cables with outer diameters between 1.025 and 1.205 inches, providing a robust mechanical and environmental seal in demanding petrochemical, oil, gas, and offshore environments. Key features include an integral sealing chamber and a disconnectable body, which eliminates the need for external cement sealants and reduces installation time by up to 40% compared to traditional fittings. The STX100-468S accepts ABB’s line of liquid and putty sealants, ensuring compatibility with a wide range of cable types and environmental conditions. Constructed from durable steel with a protective finish, it is engineered for use in Class I, II, III, Division 1 & 2, and Zone 1 & 2 hazardous locations. The fitting’s modular design simplifies maintenance and upgrades, allowing for quick disconnection and reconnection without disturbing the cable jacket or conduit system. With a compact footprint of 2.50 inches in height and 1.63 inches in width, it integrates seamlessly into existing STAR TECK XP systems, reducing inventory complexity and total cost of ownership. The gland torque requirement is 300 lb-in (33.90 Nm), ensuring a secure and reliable installation. Applications include refineries, chemical plants, offshore platforms, and pipeline systems where explosion-proof cable management is critical.
  • 1-inch hub size for hazardous location cable termination
  • Accommodates jacketed cables with outer diameters 1.025-1.205 inches
  • Integral sealing chamber eliminates need for external cement sealants
  • Reduces installation time by up to 40% compared to traditional fittings
  • Modular design allows quick disconnection and reconnection without disturbing cable jacket

Specifications

Application
For Hazardous Locations
Color
Red;Silver
Material
Steel
Size
1 Inch
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
4 IN x 4 IN x 3.3 IN
Package Dimensions (L x W x H)
10.16 cm x 10.16 cm x 8.382 cm
Package Weight (Imperial)
1.6400 L
Package Weight (Metric)
0.7440 kg
Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch

685-UI

Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch
PVC Coated Conduit Body Cover, Form 7, Size 1 Inch/27 Metric, Stamped Steel, Dark Gray

370-G1

PVC Coated Conduit Body Cover, Form 7, Size 1 Inch/27 Metric, Stamped Steel, Dark Gray
One piece strut clamp with saddle designed to secure rigid/EMT conduit or cable perpendicular to strut. It is made of steel with a galvanized finish. The clamp fits 2-1/2 in EMT and 2-1/2 in RMC and has a static load rating of 350 lbs.

CCOP250

One piece strut clamp with saddle designed to secure rigid/EMT conduit or cable perpendicular to strut. It is made of steel with a galvanized finish. The clamp fits 2-1/2 in EMT and 2-1/2 in RMC and has a static load rating of 350 lbs.
KIT GREASE FITTING WITH EXTENSION

GF 250 ODE-W22

KIT GREASE FITTING WITH EXTENSION
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.600 - 1.875 inch.

STX150-471

Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.600 - 1.875 inch.
Star Teck hazardous location steel jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.350 - 1.625 inch.

STX150-470S

Star Teck hazardous location steel jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.350 - 1.625 inch.
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.500 - 1.625 inch.

STX150-550

Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.500 - 1.625 inch.
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 2 inches. Range over jacket from 2.100 - 2.375 inches.

STX200-474

Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 2 inches. Range over jacket from 2.100 - 2.375 inches.

Frequently Asked Questions

What cable jacket sizes are compatible with this fitting?

The fitting accommodates jacketed cables with outer diameters between 1.025 and 1.205 inches.

What hazardous location certifications does the STX100-468S have?

The fitting is UL and CSA certified for Class I, II, III, Division 1 & 2, and Zone 1 & 2 hazardous locations.

What materials is the STX100-468S made from?

The fitting is constructed from durable steel with a protective finish.

Does this fitting require cement sealants?

No, the integral sealing chamber eliminates the need for external cement sealants.

Can the STX100-468S be disconnected without removing the cable?

Yes, the disconnectable design allows for quick disconnection and reconnection without disturbing the cable jacket.

Is the STX100-468S compatible with other STAR TECK XP fittings?

Yes, the modular design integrates seamlessly into existing STAR TECK XP systems.

How to Install STX Series Star Teck Cable Fittings

This guide provides step-by-step instructions for preparing cables and installing STX Series Star Teck cable fittings, including the STX150-550 model, using liquid sealing compound. Installation must be performed by a qualified electrician in accordance with national and local electrical codes.

Estimated time: 2h

Tools needed:

Hacksaw, Wire strippers, Wrench, Damp cloth, Personal Protective Equipment (PPE)

Supplies needed:

Cable (power or shielded data), SC4-KIT-1 LIQUID SEALANT, Fiber damming material

  1. De-energize Circuits

    WARNING: Verify that all circuits are de-energized before beginning any installation or maintenance procedures to prevent the risk of electrical shock.

  2. Prepare Cable Armor

    Determine the required working length of conductors inside the enclosure. Remove a portion of the cable's outer jacket to expose the armor, then cut the armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation during this process.

  3. Adjust Armor Strip Length

    Trim the outer jacket to achieve the exposed armor strip length specified in the product table for your specific STX model (e.g., 1.375-1.545 inches for STX150-550).

  4. Feed Cable

    Feed the prepared cable through the gland nut opening and push it until the cable armor firmly contacts the internal end stop.

  5. Tighten Gland Nut

    Securely tighten the gland nut to achieve an appropriate seal, or to the maximum torque specified in the table (e.g., 1200 IN-LBS for STX150-550). Ensure the bushing and collar ring seal evenly around the cable's outer jacket and are flush with the gland nut face, keeping the cable centered for an optimal seal.

  6. Disassemble Fitting

    Loosen the union to disassemble the hub from the body sub-assembly. Then, unscrew the sealing chamber from the body sub-assembly.

  7. Prepare Conductors

    Trim the inner jacket to a length of 1/8” to 3/8” to expose the conductor bundle. If working with shielded data cables, also remove the outer (overall) shield and any filler materials, taking care not to damage inner shields or conductors.

  8. Pack Fiber Damming Material

    Tightly pack the fiber damming material into all voids between the conductors and the body. If applicable, spread the strands of any uninsulated grounding conductor.

  9. Reattach Sealing Chamber

    Screw the sealing chamber back onto the body sub-assembly until it is completely seated.

  10. Mix and Dispense Liquid Sealant

    Position the cable and fitting vertically. Mix the SC4-KIT-1 liquid sealing compound according to its package instructions. Dispense the compound into the end of the sealing chamber until the level stabilizes and fills to the top (for STX150-550).

  11. Clean Excess Compound

    CAUTION: Immediately remove any excess compound material from the exterior of the sealing chamber using a damp cloth. Do not use abrasive cleaners such as powder cleaners, sandpaper, steel wool, or a wire brush, as these may damage the flame path.

  12. Mount Hub and Secure Assembly

    Mount the hub in the desired location. After the sealing compound has solidified (approximately 1 hour), place the encapsulated assembly into the hub and secure it by tightening the union until it bottoms out (metal-to-metal contact).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.