- 1-1/2 inch hub size for standard conduit connections
- Accommodates cable jackets from 1.600 to 1.875 inches
- Integral sealing chamber for simplified installation
- Disconnectable design reduces cable preparation time
- Compatible with Star Teck XP liquid and putty sealants
Specifications
Application | For Hazardous Locations |
Color | Red;Silver |
Material | Aluminum |
Size | 1-1/2 Inches |
Standard | UL E82038, CSA 23086 |
Type | Teck Cable Fittings |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.4100 L |
Package Weight (Metric) | 0.6400 kg |

MAVI-M20/01
Special 45 Degree Elbow Adapter, Metric Thread - Thread Inside/Outside M20x1.5/M20x1.5, Nickel-Plated Aluminum
95138
Clamp-on service entrance cap for 4-inch EMT and rigid/IMC conduit. It is made of aluminum with a silver color and no additional finish. The enclosure is listed as Weatherhead.
STX150-470S
Star Teck hazardous location steel jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.350 - 1.625 inch.
STX150-550
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 1-1/2 inch. Range over jacket from 1.500 - 1.625 inch.
STX200-474
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 2 inches. Range over jacket from 2.100 - 2.375 inches.
STX200-473
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 2 inches. Range over jacket from 1.900 - 2.187 inches.
STX250-475
Star Teck hazardous location aluminum jacketed cable fitting. Hub size of 2-1/2 inches. Range over jacket from 2.300 - 2.565 inches.How to Install the STX150-471 Star Teck Cable Fitting
This guide provides detailed instructions for preparing a power cable and installing the STX150-471 Star Teck cable fitting, including sealing with liquid compound.
Estimated time: 1h 30m
Tools needed:
Hacksaw, Wire strippers, Torque wrench, Damp cloth
Supplies needed:
STX150-471 cable fitting, Power cable, SC4-KIT-1 LIQUID SEALANT (2 units), Fiber damming material, Personal Protective Equipment (PPE) including gloves
- De-energize Circuits and Prepare Cable
Before starting, verify that all circuits are de-energized to prevent electrical shock. Determine the required working length of conductors inside the enclosure. Remove a portion of the cable's outer jacket to expose the armor, then cut the armor using a hacksaw. Exercise caution to avoid nicking or cutting the conductor insulation.
- Trim Outer Jacket and Feed Cable
Trim the outer jacket to achieve an exposed armor strip length between 1.475 and 1.795 inches, as specified for the STX150-471. Feed the prepared cable through the gland nut opening and push it until the cable armor firmly hits the end stop.
- Tighten Gland Nut
Tighten the gland nut to an appropriate seal or to the maximum torque of 1200 IN-LBS. Ensure that the bushing and collar ring seal evenly around the cable’s outer jacket and are flush with the gland nut face. Verify the cable remains centered for an optimal seal.
- Disassemble and Prepare for Sealing
Disassemble the hub from the body sub-assembly by loosening the union. Unscrew the sealing chamber from the body sub-assembly. Trim the inner jacket to a length of 1/8” to 3/8” to expose the conductor bundle.
- Pack Fiber Damming Material
Pack the fiber damming material tightly into all voids between the conductors and the body of the fitting. If applicable, spread the strands of any uninsulated grounding conductor to ensure thorough packing.
- Reassemble Sealing Chamber and Position
Screw the sealing chamber back onto the body subassembly until it completely seats. Position the cable and fitting assembly into a vertical orientation, which is crucial for proper liquid compound application.
- Mix and Dispense Liquid Sealing Compound
Mix the SC4-KIT-1 liquid sealing compound according to the instructions provided on its package. Carefully dispense the mixed compound into the end of the sealing chamber until the liquid level stabilizes and fills to the top.
- Clean Excess Compound
Immediately remove all excess compound material from the outside of the sealing chamber using a damp cloth. Do not use abrasive cleaners such as powder cleaners, sandpaper, steel wool, or a wire brush, as these may damage the flame path of the fitting.
- Mount Hub and Secure Assembly
Mount the hub in its desired final location. Allow the sealing compound to solidify for approximately 1 hour. Once solidified, place the encapsulated assembly into the mounted hub and secure it in position by tightening the union until it bottoms out, ensuring metal-to-metal contact.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.