Overview
- Designed for conductor range #6 AWG
- Full Neutral configuration for specific system needs
- 500 Pound Break Force rating for mechanical security
- ABB Installation Products quality and reliability
- Storm-Safe designation for enhanced environmental protection
Specifications
Application | Service Entrance Disconnects |
Insulation | Yes |
Material | Aluminum |
Special Features | Full Neutral Assembly. 500 Pound Break Force |
Standard | ANSI C119.4-2004 |
Type | Storm-Safe Pin Kits |
Wire Size | #6 AWG |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8900 L |
Package Weight (Metric) | 0.4040 kg |

SSFB 500
Mid Span Electrical Tap Storm Safe Kit, less than 1000 Volts, with Flexible Bail for Mid-Span Installations. Includes (1) Storm Safe Breakaway Link - 500 Pound Break Force. 304 Stainless Steel. Length 3-53/64 inch, Width 3/4 inch, (1) Clevis Pin - Aluminum 1-35/64 inch with Inside 'U' Radius of 7/32 inch, and (1) Bail - Plastic Jacketed Steel Aircraft Cable 3/32 inch Diameter 7 x 7.
SSP 1/0 FN 750K
Storm-Safe Pin Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 pounds break force
SSP 4 RN 500K
Storm-Safe Pin Kits triplex block - 446 neutral assembly - reduced neutral breakaway force - 500 pounds break force
SSP 2/0 RN 500K
Storm-Safe Pin Kit - Conductor Range 2/0, Reduced Neutral, breakaway force - 500 Pound Break Force
SSP 2/0 FN 500K
Storm-Safe Pin Kit - Conductor Range 2/0, Full Neutral, breakaway force - 500 Pound Break ForceHow to Install the SSP Series Service Entrance Disconnect System Multiple Service Kit
This guide provides step-by-step instructions for the safe installation and wiring of the SSP Series Service Entrance Disconnect System Multiple Service Kit, ensuring compliance with electrical codes and safety standards.
Estimated time: 2h
Tools needed:
Insulated gloves rated to appropriate voltage, Approved safety cutting device, Appropriate crimping tool, Listed crimping dies (e.g., 5/8), Torque wrench (480 in-lb capacity), Wrench or socket for U-Bolt
Supplies needed:
Breakaway link, CS 2277 Flood-Seal insulating rockets, CS 2011 Flood-Seal insulating rockets, Silicone grease, Pin connectors, Compression lugs, U-Bolt (included with contact block), Neutral wedge clamp, Load-side triplex service cable, Feed cables
- Disconnect Power and Secure Service Drop
WARNING: Danger of Electric Shock! Installation must be performed by trained installers in accordance with all applicable local, state and national electrical codes, installation standards and safety rules. Follow standard safety practices when working on energized circuits. Insulated gloves rated to the appropriate voltage must be worn when installing on live conductors. Disconnect the power cables from the transformer or feed and secure the service drop.
- Install Breakaway Link and Tighten Service Drop
Open the neutral wedge clamp and install the breakaway link between the wedge clamp and pole hardware. Tighten the service drop as required.
- Install Contact Block to Eyebolt
Install the contact block to the eyebolt with the included U-Bolt and tighten the nuts from the pole side of the contact block.
- Cut and Prepare Service Cables
Cut the service cables from the transformer or feed. If the cables are not large enough for multiple loads, replace with the proper size. Ensure the feed cables have some slack when their ends are held alongside the pads to allow the contact block to swing.
- Prepare Hot Legs with Insulating Rockets and Lugs
Cut two CS 2011 Flood-Seal® Insulating rockets at the appropriate ring using an approved safety cutting device and install them on the two hot legs. Apply silicone grease to the cables to ease installation. Crimp appropriately sized compression lugs onto the three cables (hot legs and neutral) using an appropriate crimping tool and listed dies.
- Terminate Neutral and Hot Legs to Contact Block
A) Terminate the neutral lug onto the center pad of the contact block first, ensuring the barrel is over the pad as shown in the diagram. Torque to 480 in-lb. B) Install one of the hot (energized) legs as per the neutral leg and slide the Flood-Seal® insulating rocket over the connection. Repeat for the other hot leg. NOTE: Rocket not required for Neutral leg.
- Position Load-Side Triplex Service Cable
Position the load-side triplex service cable alongside the Storm-Safe® contact block. Ensure the neutral is 6 to 12 inches longer than the phase conductor to ensure that the neutral pulls out last in a storm event.
- Install Flood-Seal Insulating Rockets on Load-Side Hot Conductors
Cut two CS 2277 Flood-Seal® insulating rockets at the appropriate ring with an approved safety cutting device and install them on the two load-side hot conductors.
- Prepare Load-Side Pin Connectors
Position the Load-side cables alongside the pin connectors and mark at 1/8 inch beyond the knurl mark. Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the Pin Connectors on the conductors with a 5/8 or equivalent die as shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 die).
- Insert Neutral Pin into Contact Block
Insert the Neutral Pin into the contact block. The neutral is the center row and is identified with a white marker. The neutral body is oversized and cannot be inserted into a hot leg tower.
- Insert Hot Leg Pins and Slide Insulating Rockets
Insert one of the hot leg pins into one of the outer contact block towers. Slide the Flood-Seal® insulating rockets over the towers. Do not use silicone grease. Repeat for the other services. NOTE: Rocket not required for Neutral leg.
- Reconnect Transformer or Feed
Reconnect the transformer or feed. Connection to the service may be made with the contact block energized, but it must not be under load.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.