ABB - Installation Products R2T28M2-N0300-B2 - Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

ABB Installation Products R2T28M2-N0300-B2 Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire…

UPC: 075114353366


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Outdoor Cable Termination, SKU R2T28M2-N0300-B2, is a 25/28 kV termination designed for Tape Shield, Wire Shield, and UniShield cable types with insulation diameters from 0.84 inches to 1.38 inches. This termination leverages shrink-fit technology and Elastimold’s pull-down jacket seal for reliable outdoor installations, covering cable sizes from #2 AWG to 1250 kcmil. The unit features a non-tracking silicone housing with superior weathering characteristics and six sheds for enhanced creepage and strike distances, ensuring long-term service in field conditions. The field-removable center core simplifies installation, while the pull-down tabs enable easy jacket seal application. The termination accommodates popular XLP and EPR cable types and includes an aluminum 2-hole spade connector for conductors ranging from 350 kcmil stranded/compressed to 400 kcmil compact/solid. A stainless steel B2 mounting bracket (adjustable 1.10–1.50 inches) provides secure cable support. The R2T28 series is engineered for maximum performance in restricted spaces and permits free-hanging applications where required. Optional insulating silicone sleeves are available for additional creepage or wildlife protection. Key electrical ratings include a maximum design voltage to ground of 16 kV, a coronal extinction voltage of 22 kV (≤3pC), and a lightning impulse withstand of 150 kV crest. The termination meets a minimum strike distance of 14.5 inches and provides a creepage distance suitable for 25/28 kV outdoor service.
  • 25/28 kV rating for Tape Shield, Wire Shield, and UniShield cables
  • Insulation range: 0.84–1.38 inches (21.3–35.1 mm)
  • Aluminum 2-hole spade connector for 350–400 kcmil conductors
  • Stainless steel B2 bracket (1.10–1.50 inches) for secure mounting
  • Non-tracking silicone housing with six sheds for superior creepage/strike distances

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.4700 L
Package Weight (Metric)
1.1200 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2T28M4N0300

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
25kv, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact for Aluminum or Copper Conductors, Power Cable Termination, Conductor Size - #2 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.

PCT20210-4

25kv, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact for Aluminum or Copper Conductors, Power Cable Termination, Conductor Size - #2 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.
25kv, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .830 to 1.180 inches.

PCT21270-3

25kv, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .830 to 1.180 inches.
25kv, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.

PCT21240-3

25kv, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #2 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. Positioning Bracket

PCT1-0210-4-PB1(1)

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #2 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. Positioning Bracket
25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - #1 Stranded/Compressed or 1/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches. Positioning Bracket.

PCT21230-4-PB1

25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - #1 Stranded/Compressed or 1/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches. Positioning Bracket.
25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .830 to 1.180 inches. Positioning Bracket

PCT21270-4-PB1

25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .830 to 1.180 inches. Positioning Bracket
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. 18 inch contact

PCT1-0220-4-18

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. 18 inch contact

Frequently Asked Questions

What cable sizes are compatible with R2T28 terminations?

R2T28 terminations accommodate cables with insulation diameters from 0.84 in (21.3 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.

Where can I find installation instructions for R2T28?

Installation instructions are available under IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

What is the creepage distance of the R2T28?

The creepage distance for the R2T28 termination is 22.8 inches (579 mm).

What is the minimum strike distance of the R2T28?

The minimum strike distance for the R2T28 termination is 14.5 inches (368 mm).

How many sheds does the R2T28 outdoor model have?

The R2T28 outdoor model features six sheds.

What optional connectors are available for the R2T28?

Optional connectors for the R2T28 include those with a copper stem, one-hole, and two-hole spade connectors.

Are support brackets available for the R2T28 termination?

Yes, optional cable and support brackets are available in four sizes, ranging from 0.80 in to 2.40 in O.D.

What mounting options are available for the R2T28?

The R2T28 termination can be mounted free hanging or with an optional bracket.

What is the maximum altitude for R2T28 installation?

The R2T28 termination has a maximum altitude range of 3300 feet (1005 m).

What power system frequency does the R2T28 support?

The R2T28 termination supports a power system frequency range of 48 to 62 Hz.

How to Install the R2T28M2 Shrink-fit Silicone Rubber Termination

This guide provides detailed instructions for safely installing the 28kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2T28M2) on tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination sealing. Always ensure apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer)

Supplies needed:

Silicone Rubber Termination, Lubricant, Gray Silicone Rubber Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves, Connector, Terminal Lug, Vinyl Tape

  1. Perform Pre-Installation Checks and Safety

    DANGER: De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Inspect the package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Gather all required tools and maintain a clean work area.

  2. Prepare the Cable

    Confirm the cable size fits within the insulation range specified in the Termination Selection Chart (Page 1). Train the cable into its final position and cut it to the required length, allowing for terminal lug depth and aluminum lug growth allowance (refer to Table 1 and diagrams for specific dimensions). Prevent the tape shield from unrolling by holding down its edge with a single wrap of the supplied copper foil tape.

  3. Install the Ground Braid

    Wrap one band of mastic around the cable jacket 1/4" (6mm) from the jacket end, stretching it to 50%. Cut the mastic flush without overlapping. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic band, maintaining the 1/4" (6mm) dimension and 50% stretch. Cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4" (6mm) dimension. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinch it after the final winding, and secure it with two wraps of vinyl tape.

  4. Install the Lug or Connector

    Check that the termination assembly can fit over the selected lug. If not, clean the cable insulation and slide the termination onto the cable before installing the lug. Do not remove the core at this stage. Position the connector or lug and crimp it according to the manufacturer's instructions, ensuring the last 3/8" to 1/2" of the connector remains uncrimped. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent, taking care not to let the solvent touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only. Do not use abrasive on the semi-conductive insulation shield. Ensure the cable insulation diameter is not reduced below the kit's specified allowance.

  6. Install the Termination Body

    Create a track-resistant moisture seal by wrapping a band of the gray silicone rubber electrical tape around the base of the terminal lug. Adjust the number of layers (not exceeding two) if the barrel diameter is equal to or greater than the cable primary insulation, or build up to the insulation diameter if smaller. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is firmly against the leading edge of the mastic seal. Continue removing the core without pushing or pulling the termination assembly.

  7. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape. Overlap the termination insulator by approximately 1" and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid securely to the system ground. Confirm that the High-K step does not exceed 1.5".

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.