Authorized ABB Distributor (Installation Products)
ABB - Installation Products LTTUS04B-J - Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1 Inch, Length 120 Meters/400 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

ABB Installation Products LTTUS04B-J Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core…

UPC: 786210223643


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 400

Multiplier: 400

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products LTTUS04B-J is a 1-inch Liquid Tight Flexible Metallic Conduit (LTFMC) designed for industrial and commercial applications requiring reliable cable protection in extreme temperature environments. The conduit features a galvanized steel core for mechanical strength and a PVC jacket for corrosion resistance and flexibility, ensuring long-term performance in harsh conditions. This conduit is rated for continuous operation from -55°C to 105°C, making it suitable for outdoor installations, refrigeration units, and high-temperature industrial processes. The 120-meter (400-foot) length provides efficient coverage for large-scale projects, reducing installation time and material waste. UL E125517 and CSA LR-72635 certifications confirm compliance with North American safety standards for liquid-tight flexible metallic conduit, ensuring reliable performance in wet or corrosive environments. The RoHS-compliant design meets environmental regulations for restricted substances. Common applications include wiring in industrial machinery, HVAC systems, solar installations, and food processing facilities where cable protection against moisture, abrasion, and temperature extremes is critical. The black finish provides UV resistance and visibility in low-light conditions. SKU: LTTUS04B-J | Manufacturer: ABB - Installation Products.
  • 1-inch galvanized steel core with PVC jacket for durability and flexibility
  • Operating temperature range: -55°C to 105°C
  • 120-meter (400-foot) length for large-scale installations
  • UL E125517 and CSA LR-72635 certified for safety and compliance
  • RoHS compliant for environmental regulations

Specifications

Application
Used with high temperature machine tool wiring
Color
Black
Finish
PVC Jacket
Inside Diameter
1.041 in
Inside Diameter
26.4414 mm
Length
400 in
Length
10160 mm
Material Quality
Galvanised Steel
Outside Diameter
1.315 in
Outside Diameter
33.401 mm
Radius
5.5118 in
Radius
140 mm
Special Features
Global certification to UL, CSA and IEC standards requirements
Standard
UL E125517, CSA LR-72635, RoHS
Trade Size
1 in
Type
Liquid Tight Flexible Metallic Conduit
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8500 L
Package Weight (Metric)
0.3860 kg
Liquid Tight, High Temperature Conduit, Nominal Conduit Size 32mm, 1 Inch US Trade Size, Outside Diameter 33.1mm, Inside Diameter 26.7mm, Static Bend Radius 145mm, Reel Length 20 Meters, IP66, IP67 Ratings, Stainless Steel AISI 316L Core, String Packing with Thermoplastic Rubber Covering, Black

FSH0620

Liquid Tight, High Temperature Conduit, Nominal Conduit Size 32mm, 1 Inch US Trade Size, Outside Diameter 33.1mm, Inside Diameter 26.7mm, Static Bend Radius 145mm, Reel Length 20 Meters, IP66, IP67 Ratings, Stainless Steel AISI 316L Core, String Packing with Thermoplastic Rubber Covering, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 60 Meters/200 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS05B-E

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 60 Meters/200 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS03B-K

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS06B-D

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS03B-L

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear

LT6GES07C-B

Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear

LT6GES07C-C

Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear

LT6GES06C-D

Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear

Frequently Asked Questions

How does the LTXE jacket resist 10W-40 Motor Oil at 100 °C?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 50% tensile strength and 55% elongation, with a 25% volume increase when exposed to 10W-40 Motor Oil.

How is chemical resistance rated for PVC and PU materials?

Chemical resistance for PVC and PU is rated using a scale from A (Excellent to Good) to D (Unsatisfactory), with B (Good to Fair) and C (Fair to Limited) in between.

Is the chemical resistance data guaranteed for all applications?

No, this information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.

What is recommended for extreme or unusual chemical exposure situations?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations.

How does the LTXE jacket resist ASTM #2 Oil at 60 °C?

After 7 days at 60 °C, the LTXE thermoplastic rubber jacket retains 90% tensile strength and 98% elongation when exposed to ASTM #2 Oil.

What is the LTXE jacket's resistance to Gasoline at 100 °C?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 40% tensile strength and 35% elongation, with a 17% volume increase when exposed to Gasoline.

How does the LTXE jacket resist Silicon Oil at 100 °C?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 100% tensile strength and 80% elongation, with a 14% volume decrease when exposed to Silicon Oil.

What is the LTXE jacket's resistance to Transmission Oil at 100 °C?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 50% tensile strength and 50% elongation, with a 32% volume increase when exposed to Transmission Oil.

How does the LTXE jacket resist Freon2 at 80 °C?

After 72 hours at 80 °C, the LTXE thermoplastic rubber jacket retains 93% tensile strength and 84% elongation when exposed to Freon2.

How does the LTXE jacket resist 5% Salt Water at 100 °C?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 80% tensile strength and 100% elongation, with a 1% volume increase when exposed to 5% Salt Water.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.