ABB Installation Products LTTUS06B-D Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core…
UPC: 786210223667
Documents & Media
Contact for Pricing
Minimum Qty: 150
Multiplier: 150
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Galvanised Steel Core with PVC Jacket for durability and flexibility
- 1-1/2 Inch Conduit Size
- 45 Meters (150 Feet) Length
- Wide Working Temperature Range: -55°C to 105°C
- UL E125517 and CSA LR-72635 Listed, RoHS Compliant
Specifications
Application | Used with high temperature machine tool wiring |
Color | Black |
Finish | PVC Jacket |
Inside Diameter | 1.575 in |
Inside Diameter | 40.005 mm |
Length | 50 in |
Length | 1270 mm |
Material Quality | Galvanised Steel |
Outside Diameter | 1.9 in |
Outside Diameter | 48.26 mm |
Radius | 4.4882 in |
Radius | 114 mm |
Special Features | Global certification to UL, CSA and IEC standards requirements |
Standard | UL E125517, CSA LR-72635, RoHS |
Trade Size | 1-1/2 in |
Type | Liquid Tight Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.3600 L |
Package Weight (Metric) | 0.6170 kg |

SPTC50/10M
Highly Flexible Conduit, Nominal Conduit Size 50mm, Outside Diameter 56.0mm, Inside Diameter 48.4mm, Static Bend Radius 90mm, Reel Length 10 Meters, Galvanised Steel Core with PVC Jacket and Tinned Copper Overbraid, Black
LTTUS03B-L
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LT6GES07C-B
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES07C-C
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES06C-D
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES06C-B
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES02C-C
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES02C-K
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, ClearFrequently Asked Questions
What is PVC's resistance to 10% Acetic Acid?
PVC has "Good to Fair" (B) resistance to 10% Acetic Acid.
What does an "A" rating signify in the chemical resistance guide?
An "A" rating indicates excellent to good chemical resistance for the material.
What is the volume change of the LTXE jacket in Silicon Oil?
After 72 hours at 100 °C, the LTXE jacket shows a -14% volume increase (decrease) when exposed to Silicon Oil.
How does the LTXE jacket react to Transmission Oil?
After 72 hours at 100 °C, the LTXE jacket shows 50% tensile strength, 50% elongation, and a 32% volume increase with Transmission Oil.
What is the effect of Gasoline on the LTXE thermoplastic rubber jacket?
After 72 hours at 100 °C, the LTXE jacket shows 40% tensile strength, 35% elongation, and a 17% volume increase with Gasoline.
How does the LTXE jacket perform with ASTM #2 Oil?
After 7 days at 60 °C, the LTXE jacket retains 90% tensile strength and 98% elongation when exposed to ASTM #2 Oil.
What does a "D" rating mean for chemical resistance?
A "D" rating signifies unsatisfactory chemical resistance for the material.
Is the product resistant to water?
Both PVC and PU materials show "Excellent to Good" (A) resistance to Water.
How resistant is PU to 50% Sulfuric Acid?
PU has "Excellent to Good" (A) resistance to 50% Sulfuric Acid.
What is the resistance of PVC to 100 Octane Gasoline?
PVC has "Fair to Limited" (C) resistance to 100 Octane Gasoline.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.