Authorized ABB Distributor (Installation Products)
ABB - Installation Products K675SR-M2420 - 900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size kcmil Compacted Solid 1250.

ABB Installation Products K675SR-M2420 900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining…

UPC: 783786675517


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K675SR-M2420 is a 900 Amp, 15/25kV straight receptacle designed for medium-voltage cable connections. This 600 Series component includes a copper compression lug rated for 1250 kcmil compacted solid conductors, ensuring reliable current transfer in high-load applications. The integrated cable adapter accommodates insulation diameters from 1.370 inch to 1.630 inch, providing compatibility with a range of cable types. The retaining ring secures the assembly, preventing disconnection under mechanical stress or vibration. This receptacle is part of ABB’s Installation Products line, known for durable, field-proven components in power distribution systems. Typical applications include utility substations, industrial power feeds, and commercial infrastructure where medium-voltage cable terminations require secure, high-current connections. The copper compression lug eliminates the need for additional splicing, reducing installation time and potential failure points. For environments requiring compliance with medium-voltage standards, the K675SR-M2420 delivers consistent performance with minimal maintenance.
  • 900 Amp rated current for high-load applications
  • 15/25kV voltage rating for medium-voltage systems
  • Copper compression lug for 1250 kcmil compacted solid conductors
  • Cable insulation diameter range: 1.370" to 1.630"
  • Includes cable adapter, lug, and retaining ring for secure termination

Specifications

Amperage Rating
900 A
Application
15/25kV, 900 Amps
Color
Black
Conductor Range
1250 kcmil
Connection
Compression
Connection Type
Straight Receptacle with Cable Adapter
Current Rating
900 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Copper
Series
600 Series
Size
1.370-1.630 inch
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1250 kcmil. Cold-Shrinkable Jacket Seal Included.

776LR-Q2440-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1250 kcmil. Cold-Shrinkable Jacket Seal Included.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

K655YSR-J0300-S

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K656I-N0410

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K656CH-L0320-SG1

600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
600 Amps, 15/25kV, Deadbreak, Elbow, Current Carrying over 1000 Volts. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Compacted Solid 2/0.

655LR-F0240

600 Amps, 15/25kV, Deadbreak, Elbow, Current Carrying over 1000 Volts. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Compacted Solid 2/0.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656CY-M0380

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

Is a ground kit recommended for certain cables?

Yes, an ECS type ground kit/cable seal is recommended when using metallic tape shield or drain wire cable.

What is the K675SR product designed for?

The K675SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings and allows straight cable connections on switchgear.

What cable sizes are compatible with K675SR?

The K675SR product range supports #2 AWG to 1250 kcmil for aluminum and copper conductors.

What are the insulation diameter requirements?

Compatible cables must have insulation diameters ranging from 0.640 inches to 1.935 inches.

What is the continuous current rating for K675SR?

The K675SR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

What is the maximum operating voltage for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and phase-to-phase is 28kV.

What standards does the K675SR meet?

The K675SR meets ANSI/IEEE Standard 386, Latest Revision.

Can the K675SR be connected or disconnected energized?

No, the K675SR can only be easily connected or disconnected in a de-energized state.

What other products mate with the K675SR?

The K675SR mates with K675S1 and K675T1.

How to Install the K655SR/M655SR Deadbreak Straight Receptacle

This guide provides step-by-step instructions for installing the K655SR or M655SR Deadbreak Straight Receptacle, covering apparatus bushing preparation, cable management, and component connection for a secure high-voltage interface. DANGER: All apparatus must be de-energized during installation by competent personnel trained in high voltage safety.

Estimated time: 2h

Tools needed:

5/8-11 tap, Hex wrench, Wire brush, Torque wrench, 15/16 socket, Crimping tool, Wire strippers

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricants, Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire, Suitable connector, Hose clamp (for 35kV only)

  1. Prepare Apparatus Bushing

    If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using a 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Prepare Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Manage Concentric Neutral Wires (If Applicable)

    Unwrap the concentric neutral wires (if applicable) a distance of 30” (76cm). Do not cut them. Bend and fold them back out of the way.

  4. Clean Outer Cable Jacket

    Wipe the outer jacket clean for a distance of 38” (96.5cm) or up to the concentric neutral wires.

  5. Slide Receptacle Housing

    Slide the receptacle housing onto the cable a distance of 30” (76cm).

  6. Prepare Semi-Con Shield

    Remove the semi-con shield and install a tape marker to the dimensions shown in the diagram (10-1/4” (26.04cm) from the end of the cable insulation, and 11-1/4” (28.58cm) from the end of the semi-con shield). Do not cut or nick the cable insulation.

  7. Install Cable Adapter

    Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  8. Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4” – 5” (12.06cm – 12.7cm). If the length is incorrect, redo the assembly.

  9. Position Holding Collar

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. The exposed conductor length should be 4 3/8” – 4 3/4” (11.11cm – 12.06cm).

  10. Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Make sure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If the distance is over 7” (17.8cm), do not proceed and redo all previous work.

  11. Confirm Component Orientation and Alignment

    Confirm that components are oriented in the order: Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  12. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90˚. After crimping, measure the distance from the end of the connector to the holding collar. If the distance is over 7” (17.8cm), do not proceed and redo all previous work.

  13. Assemble and Torque Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), hex-head bolt. Hand tighten. The splice and cables are now in their final positions. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  14. Lubricate Cable and Bushing Adapters

    Apply supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the diagram. Do not substitute other lubricants, as they may be harmful to this product or its mating product.

  15. Seat Receptacle Housing and Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly without damaging the eye. Gather the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  16. Secure with Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.