ABB - Installation Products K675LR-M2410 - 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products K675LR-M2410 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable…

UPC: 783786296576


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K675LR-M2410 is a 900 Amp, 15/25kV 600 Series deadbreak elbow connector engineered for medium-voltage cable systems. This fully shielded, submersible elbow provides a complete termination solution for compressed stranded copper conductors sized at 1000 kcmil AWG, with cable insulation diameters ranging from 1.370 inch to 1.630 inch. The connector includes an insulated plug, cap, stud, copper compression lug, and cable adapter, ensuring a secure and low-resistance electrical connection critical for high-current applications. The 600 Series design meets ANSI/IEEE Standard 386, offering reliable performance in power distribution, substations, and industrial installations where medium-voltage terminations are required. Key electrical ratings include a maximum phase-to-ground operating voltage of 8.3kV (15kV class) or 16.2kV (25kV class), with a continuous current rating of 900 Amps and a momentary rating of 25kA symmetrical for 10 cycles. The fully molded rubber housing provides full shielding and dead-front safety, reducing the risk of accidental contact during installation and maintenance. Compatible with metallic tape shield or drain wire cables, the K675LR-M2410 can be mated with other Elastimold® products such as the K675CP, K675BIP, and K650J series for expanded functionality. The connector is designed for use with standard hand tools and equipment in a de-energized state, ensuring ease of installation without specialized equipment. Ideal for medium-voltage power distribution systems, this elbow connector is a critical component in applications requiring reliable, high-current terminations with full shielding and submersible capabilities.
  • 900 Amp continuous current rating for high-power applications
  • Fully shielded, dead-front, and submersible design for safety
  • Compatible with 1000 kcmil AWG compressed stranded copper conductors
  • Cable insulation diameter range: 1.370 inch to 1.630 inch
  • Includes insulated plug, cap, stud, and cable adapter for complete termination

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Connection Type
Elbow with Insulated Plug
Current Rating
900 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Copper
Series
600 Series
Size
1.370 inch to 1.630 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.2500 L
Package Weight (Metric)
3.2890 kg
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.

K676LR-M2410

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
600 Amp, 25kV, Test and Ground Replacement Connector Kit with Insulating Cap. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655RETP-P0380-DRG

600 Amp, 25kV, Test and Ground Replacement Connector Kit with Insulating Cap. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656ETPL0300

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K675LR-L-2330-SG1

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
15/25kV 600 Series Deadbreak 4-Way L-Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K655L4-H5270-S

15/25kV 600 Series Deadbreak 4-Way L-Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K675LR-N2410

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

Frequently Asked Questions

What is the corona extinction voltage for the 15kV class?

For the 15kV voltage class, the corona extinction voltage is 11kV AC at 3pC sensitivity.

What is the BIL impulse withstand rating for 28kV class?

For the 28kV voltage class, the BIL impulse withstand rating is 140kV (1.2 x 50 microsecond wave).

What items are included in a K675LR kit?

Each kit contains an elbow connector housing, copper compression lug, copper stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

What standard does the K675LR elbow connector meet?

The K675LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

Which Elastimold products are compatible with the K675LR?

The K675LR can be mated with Elastimold products including K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.

What is the maximum operating voltage for the K675LR?

The maximum phase-to-phase operating voltage is 14.4kV for the 15kV class and 28kV for the 28kV class.

What is the continuous current rating for the K675LR?

The K675LR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What conductor types and sizes are compatible with K675LR?

It is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil. Insulation diameters can range from 0.640 in to 1.935 in.

What is the K675LR elbow connector used for?

The K675LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

What is the corona extinction voltage for the 15kV class?

For the 15kV voltage class, the corona extinction voltage is 11kV AC at 3pC sensitivity.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation, cable preparation, and connection of 655/675LR and K655/K675LR deadbreak elbow connectors on 15kV and 25kV class systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device

Supplies needed:

Lubricant, Threaded stud, No. 14 AWG Copper wire, HV insulated cap(s) or connector(s), Silicone lubricant, Waterproofing material, Terminal connectors, Tape marker

  1. Prepare for Installation and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all package contents for completeness and damage, and verify component compatibility and fit with the cable and mating products. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors if the circuit will be submerged or energized. Have all required tools ready and maintain a clean work area.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and tape marker according to the specified dimensions (9-3/4in, 10-3/4in, 12-3/4in).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Carefully remove any protruding cable insulation by cutting it even with the end of the cable adapter. Ensure not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug following the supplied instructions. After crimping, wipe off all excess inhibitor. The distance from the end of the compression lug to the cable adapter must be between 6-3/8 inches to 7-1/8 inches (162mm-181mm).

  6. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; reposition if necessary. Finally, remove the tape marker.

  7. Connect the Elbow to Mating Products

    DANGER: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part thoroughly. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud. For the opposite end, clean and lubricate the mating part, insert it into the elbow, engage the threads, hand tighten, and then torque according to the mating part's instructions. If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap and push it onto the elbow until it snaps into place.

  8. Ground the Cable Shield and Waterproof the Jacket

    Insert one end of a wire, with ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist to form a small loop without damaging the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either through a grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  9. Verify Torque for L-Kits (If Applicable)

    CAUTION: If constructing 600-amp L-Kits, ensure that each component is tightened to the specified torque according to the instructions provided with the L-Kit.

  10. Perform Voltage Test

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, designed for capacitive test points, to determine if the cable is energized. Be aware that contamination, moisture, or incorrect equipment can lead to a false 'no voltage' indication. Always treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.