ABB - Installation Products K656SR-G2240-S - 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0. S - Cold Shrinkable Jacket Seal.

ABB Installation Products K656SR-G2240-S 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining…

UPC: 075114413114


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series Straight Receptacle, SKU K656SR-G2240-S, is a 600 Amp, 15/25kV-rated termination solution designed for medium-voltage cable systems. This straight receptacle integrates a cable adapter, copper compression lug, and retaining ring to ensure secure, low-resistance connections in demanding electrical installations. The integrated cold shrinkable jacket seal (S) provides environmental protection for cable insulation diameters ranging from 0.760 to 0.950 inches, preventing moisture ingress and contamination. The copper compression lug accommodates AWG compressed stranded 1/0 or compacted solid 2/0 conductors, offering compatibility with a wide range of cable types. The 600 Series design emphasizes straightforward installation with minimal tools, reducing downtime in field applications. Typical use cases include utility substations, industrial power distribution, renewable energy systems, and commercial infrastructure where reliable medium-voltage terminations are critical. The receptacle housing (K656BSR) and adapter (K650SRA) are included, along with installation hardware and lubricant for optimal performance. This product is part of ABB’s Installation Products portfolio, engineered for medium-voltage cable management in harsh environments.
  • 600 Amp, 15/25kV-rated straight receptacle for medium-voltage cable systems
  • Includes cable adapter, copper compression lug, and retaining ring for secure connections
  • Cold shrinkable jacket seal (S) protects cable insulation diameters from 0.760" to 0.950"
  • Accommodates AWG compressed stranded 1/0 or compacted solid 2/0 conductors
  • Designed for utility substations, industrial power distribution, and renewable energy systems

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
EPDM Rubber
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point and Jacket Seal
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.9 inch to 2.12 inch. Conductor Size Range for Compressed / Stranded / Compacted 1500 kcmil. 35 kV Only.

756LR-QAC05

35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.9 inch to 2.12 inch. Conductor Size Range for Compressed / Stranded / Compacted 1500 kcmil. 35 kV Only.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed Stranded 3/0 or Solid Compact 4/0. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Includes Elbow Connector Housing, Long Bi-Metal Compression Lug, Probe Wrench, Probe, Hose Clamp, Crimp Chart, Installation Instructions and Tube of Lubricant.

168RLR-J5260-SG3

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed Stranded 3/0 or Solid Compact 4/0. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Includes Elbow Connector Housing, Long Bi-Metal Compression Lug, Probe Wrench, Probe, Hose Clamp, Crimp Chart, Installation Instructions and Tube of Lubricant.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Copper Compression Lug

162LR-B2200

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Copper Compression Lug
Flood Seal, Direct Burial Service Cluster, Kit of Two Assemblies with Finished Cable Length of 12 inches. (Kit1 - CL 3104 and Kit2 - CL 40-2104). Kit1. CL 3104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 1/0 STR AL Cable 15.487 x 1.5, (1) #4 STR AL Cable 15.487 x .765, (1) RRS 2010 - Radiating Rib, Aluminum Compression Splice, 2/0 to 1/0, Aluminum. 3.000 inch Long x Widest Diameter .812 inch. Center Stop. Gray Cap and Yellow Cap, Oxide Inhibiting Compound. Flood Seals assembled on 1/0 and #4 Wires. Kit2. CL 40-2104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, (1) #4 STR AL Cable 15.487 x .965, RRS 40 - (attached to 4/0 Wire) Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 and #4 Wires.

CL 8222 K

Flood Seal, Direct Burial Service Cluster, Kit of Two Assemblies with Finished Cable Length of 12 inches. (Kit1 - CL 3104 and Kit2 - CL 40-2104). Kit1. CL 3104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 1/0 STR AL Cable 15.487 x 1.5, (1) #4 STR AL Cable 15.487 x .765, (1) RRS 2010 - Radiating Rib, Aluminum Compression Splice, 2/0 to 1/0, Aluminum. 3.000 inch Long x Widest Diameter .812 inch. Center Stop. Gray Cap and Yellow Cap, Oxide Inhibiting Compound. Flood Seals assembled on 1/0 and #4 Wires. Kit2. CL 40-2104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, (1) #4 STR AL Cable 15.487 x .965, RRS 40 - (attached to 4/0 Wire) Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 and #4 Wires.
Flood Seal, Direct Burial Service Cluster, Kit of Three Assemblies with Finished Cable Length of 12 inches. (Kit1 - CL 3104, Kit2 - CL 40-210 and Kit3 - CL 40-2104). Kit1. CL 3104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 1/0 STR AL Cable 15.487 x 1.5, (1) #4 STR AL Cable 15.487 x .765, (1) RRS 2010 - Radiating Rib, Aluminum Compression Splice, 2/0 to 1/0, Aluminum. 3.000 inch Long x Widest Diameter .812 inch. Center Stop. Gray Cap and Yellow Cap, Oxide Inhibiting Compound. Flood Seals assembled on 1/0 and #4 Wires. Kit2. CL 40-210 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, RRS 40 - Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 Wires. Kit3. CL 40-2104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, (1) #4 STR AL Cable 15.487 x .965, RRS 40 - (attached to 4/0 Wire) Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 and #4 Wires.

CL 6858 K

Flood Seal, Direct Burial Service Cluster, Kit of Three Assemblies with Finished Cable Length of 12 inches. (Kit1 - CL 3104, Kit2 - CL 40-210 and Kit3 - CL 40-2104). Kit1. CL 3104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 1/0 STR AL Cable 15.487 x 1.5, (1) #4 STR AL Cable 15.487 x .765, (1) RRS 2010 - Radiating Rib, Aluminum Compression Splice, 2/0 to 1/0, Aluminum. 3.000 inch Long x Widest Diameter .812 inch. Center Stop. Gray Cap and Yellow Cap, Oxide Inhibiting Compound. Flood Seals assembled on 1/0 and #4 Wires. Kit2. CL 40-210 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, RRS 40 - Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 Wires. Kit3. CL 40-2104 - Boot plus (2) 1/0 STR AL Cables 15.487 x .965, (1) 4/0 STR AL Cable 15.487 x 2.05, (1) #4 STR AL Cable 15.487 x .965, RRS 40 - (attached to 4/0 Wire) Radiating Rib, Aluminum Compression Splice, 4/0, Aluminum. 4.300 inch long x .876 inch at widest Diameter. Center Stop. Pink Caps. Contains Oxide Inhibitor. Flood Seals assembled on 1/0 and #4 Wires.
35kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Bi-Metal Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 12.28 x 13.93 inches, 3.37 and 3.83 inch diameters.

756LR-M5330

35kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Bi-Metal Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 12.28 x 13.93 inches, 3.37 and 3.83 inch diameters.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Window OP Kit, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Tin Plated Aluminum ShearBolt Connector. Conductor Size 4/0 Stranded/Compressed/Compact AWG to 500 kcmil Stranded/Compressed/Compact.

655ETP-LAC02-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Window OP Kit, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Tin Plated Aluminum ShearBolt Connector. Conductor Size 4/0 Stranded/Compressed/Compact AWG to 500 kcmil Stranded/Compressed/Compact.

Frequently Asked Questions

Does the K656SR include a test point?

Yes, the K656SR includes a non-corrosive capacitive test point as a standard feature.

What accessories are included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

Can the K656SR be connected or disconnected while energized?

No, the K656SR can only be easily connected or disconnected in a de-energized state.

What is the continuous current rating of the K656SR?

The K656SR has a continuous current rating of 600 Amps. This applies to both 15kV and 28kV voltage classes.

What are the operating voltage limits for 28kV class?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV. The maximum phase-to-phase operating voltage is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV. The maximum phase-to-phase operating voltage is 14.4kV.

What cable sizes are compatible with K656SR?

The K656SR supports #2 AWG to 1250 kcmil for aluminum and copper conductors. It accommodates insulation diameters from .640 inches to 1.935 inches.

What is the K656SR designed for?

The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.

What accessories are included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

What is the K656SR designed for?

The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.

How to Install the K656SR Straight Receptacle

Install and assemble the K656SR straight receptacle onto a compatible ANSI-386 600 amp bushing. This guide covers cable preparation, connector assembly, final housing installation, grounding, and optional 35 kV hose clamp setup.

Tools needed:

Hex wrench, Torque wrench with 15/16 socket, 5/8-11 tap, Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

K656SR receptacle kit components, Loctite, Cable adapter, Crimp connector, Flat washer, Belleville washer, Hex-head bolt, No. 14 AWG copper wire or equivalent, Suitable connector for neutral wires, Lubricant or ELASTIMOLD approved lubricant, Hose clamp (35 kV only)

  1. De-energize and inspect all parts

    De-energize all apparatus before starting. Do not touch or move energized products in the work area. Inspect the package contents for completeness, damage, rating, and compatibility with the cable and mating bushing. Read the full instructions and keep all required tools and supplies ready.

  2. Prepare the apparatus bushing

    If a stud is present in the apparatus bushing, remove it and re-tap the hole with a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing, apply 3-4 drops of Loctite to the brass bolt threads, install the contact adapter with the bolt hole facing out, and torque the 5/8-inch brass bolt to 60 ft-lbs.

  3. Prepare and position the cable

    Straighten the cable end and cut it squarely. If concentric neutral wires are present, unwrap them 30 inches and bend them back without cutting. Wipe the outer jacket clean for 38 inches or up to the concentric neutral wires, then slide the receptacle housing onto the cable 30 inches.

  4. Strip the cable and install the cable adapter

    Remove the semi-conductive shield to the specified dimensions and apply the tape marker without nicking the insulation. Bevel the cable insulation end at a 45-degree angle about 1/4 inch back, then clean and lubricate the insulation while working toward the semi-conductive shield. Install the cable adapter small end first until it is flush with the tape marker.

  5. Expose the conductor and secure the holding collar

    Trim the protruding insulation even with the end of the cable adapter without cutting the adapter or conductor. Verify that the exposed conductor length is 4 3/4 to 5 inches. Position the holding collar flush against the cable adapter and tighten the setscrew with the supplied hex wrench.

  6. Install and crimp the connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the inhibitor-filled crimp barrel until fully seated. Verify the connector-to-holding-collar distance does not exceed 7 inches. Confirm the parts are oriented correctly and align the bolt holes in the crimp connector and contact adapter. Crimp the connector according to the connector instructions, rotating each crimp 90 degrees, then recheck the 7-inch maximum.

  7. Assemble and torque the splice

    Install the flat washer against the spade contact, then the Belleville washer with the concave side down, and finally the hex-head bolt. Hand tighten first, then use a torque wrench with a 15/16 socket to tighten to 50-60 ft-lbs. Do not attempt to move or reposition any part after tightening.

  8. Lubricate and seat the receptacle housing

    Apply the supplied or ELASTIMOLD-approved lubricant generously to the outside of the cable adapter and the bushing adapter interface. Slide the receptacle housing over the cable adapter to the interface, insert the nylon venting rod, and slide the housing fully onto the bushing converter until seated. Remove the venting rod after seating.

  9. Ground the assembly and connect neutrals

    Connect a short piece of No. 14 AWG copper wire or equivalent to the grounding eye of the receptacle housing, making a small loop and twisting it tightly without damaging the eye. Gather the concentric neutral wires and connect them to the grounding wire using a suitable connector.

  10. Install the 35 kV hose clamp if required

    For 35 kV applications only, position the hose clamp between the locator bumps on the receptacle housing and tighten it until an audible click is heard.

  11. Verify voltage safely with the test point

    If the connector includes a capacitive test point, remove the cap with a hotstick by peeling it off at an angle. Use only a suitable sensing device designed for capacitive test points; do not use conventional voltage measuring equipment. Treat the elbow as energized until a no-voltage indication is confirmed by other means. After testing, clean and lubricate the inside of the cap with the supplied silicone lubricant and reinstall it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.